Records from 1986 to 1998. Most recent: inspection, 2 October 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 2 October 1998
Resolved
BATTERY ROOM VENT WASTED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Documentation
Issued 2 October 1998
Resolved
vessel does not have a valid safety equipment certificate onboard.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Construction/Loadline
Issued 2 October 1998
Resolved
DOOR FROM HOSPITAL SPACE TO OPEN DECK CANNOT BE OPENED DUE TO CORROSION.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Documentation
Issued 2 October 1998
Resolved
COOK AND ELECTRICIANS PANANMANIAN LICENCES EXPIRED.
Condition: Unknown
Due 5 October 1998
Resolved 13 October 1998
Accommodation/Occupational Safety
Issued 2 October 1998
Resolved
EXHAUST TRUNK OVER GALLEY STOVE HEAVILY OILED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
BATTERY ROOM PORT SIDE BEHIND BRIDGE HAS IMPROPERLY CONNECTED BATTERIES AS WELL AS UNUSABLE BATTERIES.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Engineering
Issued 2 October 1998
Resolved
VESSEL MANUVERING FACT SHEET MISSING PROPER WARNING LABEL.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
DAYLIGHT SIGNALING LAMP BATTERY WAS NOT PROPERLY CHARGED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
VESSELS TWO WAY RADIOS FOR LIFEBOATS HAD CRUSHED L.E.D. READOUT SCREENS.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Accommodation/Occupational Safety
Issued 2 October 1998
Resolved
A/C HATCH STARBOARD SIDE A/C ROOM WASTED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
ELECTRICAL TRANSMITTER COOLING VENT WASTED ALLOWING WATER TO ENTER.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
ELECTRICAL TRANSMITTER ROOM FILLED WITH OLD PAPER.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Fire Fighting
Issued 2 October 1998
Resolved
STARBOARD LIFEBOAT FIRE EXT. NOT CHARGED.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Unknown
Issued 2 October 1998
Resolved
WOOD PLATFORM AROUND MAGNETIC COMPASS ROTTED AND DETERIATED
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
STARBOARD LIFEBOAT BILGE PUMP NOT OPERATIONAL.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
STARBOARD LIFEBOAT CAN NO LONGER BE RIGGED TO SAIL BECAUSE OF ALTERATIONS TO SEATS.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
STARBOARD LIFEBOAT HAS SEATS AND FLOOR BOARDS NOT SECURED.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
STARBOARD LIFEBOAT NO LONGER SERVICEABLE DUE TO ALTERATIONS IN ENGINE FUEL SYSTEM.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
LADDER ON DAVIT STARBOARD SIDE MISSING. MISSING CABLE,PENNANTS, AND GRAPS IN POOR CONDITION.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
CREW UNFAMMILAR WITH DUTIES DURING BOTH ABANDON SHIP AND FIRE DRILLS.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
CREW UNABLE TO PERFORM SATISFACTORY FIRE DRILL
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Accommodation/Occupational Safety
Issued 2 October 1998
Resolved
access panel aft a/c room wasted.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
BARE BULBS AND POOR WIRING TO HEATING MOTORS IN E/R.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
BARE BULBS AND BROKEN LIGHT FIXTURES THROUGHOUT VESSEL.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
QUICK RELEASE SMOKE AND LIFE BOUYS INOP. AND EXPIRED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
POST INSTRUCTION FOR PAINT LOCKER CO2
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Engineering
Issued 2 October 1998
Resolved
INSULATION AND LAGGING IN UPPER SPACE
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
LADDER FROM OFFICER DDECK TO CAPTAINS DECK WASTED.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Engineering
Issued 2 October 1998
Resolved
CEMENT PATCH ON LUBE OIL COOLER.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
GENERAL HOUSEKEEPING IN HYDRAULIC ROOM, FOREPEACK STORES, PAINT(CO2 RROOM)
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
CREW TO PERFORM SATISFACTORY LIFE BOAT DRILL PRIORT O DEPARTURE.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
MAIN ELECTRICAL CONDUIT IN NEED OF REPAIRS.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Lifesaving
Issued 2 October 1998
Resolved
PORT AND STARBOARD LIFEBOATS HAD MANY ITEMS THAT WERE NOT SECURED OR TIED DOWN.
Condition: Unknown
Due 3 October 1998
Resolved 13 October 1998
Electrical
Issued 2 October 1998
Resolved
VESSEL HAS EXPOSED WIRING THROUGH OUT THE ENTIRE SHIP. ON ALMOST ALL WALLS AND OVERHEADS OF LIVING SPACES.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Accommodation/Occupational Safety
Issued 3 November 1997
Resolved
REPAIR LIGHTS IN HOSPITAL SPACE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Lifesaving
Issued 3 November 1997
Resolved
REPAIR OR REPLACE GENERAL ALARM IN GALLEY PASSEGEWAY.
Condition: Unknown
Due 2 November 1998
Resolved 13 October 1998
Construction/Loadline
Issued 3 November 1997
Resolved
REPAIR LIFELINES(RAIL) FORWARD JUST AFT OF FORWARD CLEAT.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Navigation
Issued 3 November 1997
Resolved
OBTAIN CURRENT COAST PILOT AND NEW LIGHT LIST OR PROPERLY CORRECT .
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Engineering
Issued 3 November 1997
Resolved
REMOVE OIL FROM DECK IN STEERING GEAR ROOM.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Navigation
Issued 3 November 1997
Resolved
PROVIDE CLASS LETTER OF ADEQUACY FOR STEERING GEAR WHICH WOULD NOT MOVE PAST 35 DEGREES TO PORT.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Accommodation/Occupational Safety
Issued 3 November 1997
Resolved
REMOVE LOCK FROM ENGINE DOOR, STBD SIDE, AT PASSAGE WAY, JUST FORWARD OF GALLEY DOOR TO PERMIT ACCESS IN A EMERGENCY.
Condition: Unknown
Due 2 October 1998
Resolved 2 October 1998
Construction/Loadline
Issued 3 November 1997
Resolved
REPAINT LOADLINE TO BE CONTRASTING IN COLOR TO HULL.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Navigation
Issued 20 October 1988
Resolved
33 CFR 164.38(B)(3)(III) NO LABLED ARPA ON BOARD.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Navigation
Issued 20 October 1988
Resolved
33 CFR 164.35(I) CONTINUOUS RECORDER FOR ECHO DEPTH SOUNDER INOP.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996
Accommodation/Occupational Safety
Issued 6 August 1986
Resolved
VESSEL BOARDED PORT OF TOLEDO 06 AUG 86 BY MSO TOLEDO BOARDING PARTY FOR ANNUAL EXAM. BOARDING DISCLOSED VESSEL DID NOT HAVE THE OPERATING INSTRUC- TIONS PLACARD AFFIXED TO THE MSD.
Condition: Unknown
Due 7 August 1986
Resolved 6 August 1986
Navigation
Issued 6 August 1986
Resolved
VESSEL BOARDED PORT OF TOLEDO 06 AUG 86 BY MSO TOLEDO BOARDING PARTY FOR ANNUAL EXAM. BOARDING DISCLOSED VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 7 August 1986
Resolved 6 August 1986
Engineering
Issued 6 August 1986
Resolved
VESSEL BOARDED PORT OF TOLEDO 06 AUG 86 BY MSO TOLEDO BOARDING PARTY FOR ANNUAL EXAM. BOARDING DISCLOSED VESSEL DID NOT HAVE ON BOARD A DISCHARGE OFOIL PROHIBITED PLACARD.
Condition: Unknown
Due 7 August 1986
Resolved 6 August 1986
Engineering
Issued 6 August 1986
Resolved
VESSEL BOARDED PORT OF TOLEDO 06 AUG 86 BY MSO TOLEDO BOARDING PARTY FOR ANNUAL EXAM. BOARDING DISCLOSED VSLS OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 7 August 1986
Resolved 6 August 1986
Accommodation/Occupational Safety
Issued 6 August 1986
Resolved
VESSEL BOARDED PORT OF TOLEDO 06 AUG 86 BY MSO TOLEDO BOARDING PARTY FOR ANNUAL EXAM. BOARDING DISCLOSED THE OPERATING INSTRUCTION MANUAL FOR THE MSD WAS INCOMPLETE.
Condition: Unknown
Due 7 August 1986
Resolved 6 August 1986