MAURY USCG vessel records Sign in
← All vessels

KATINA

KATINA is a 1980 freight ship. The Coast Guard has recorded 21 inspections since 1986, most recently in July 2006, along with 15 deficiencies and 3 operational controls.

Records from 1986 to 2006. Most recent: operational control imposed, 11 July 2006.

Built
1980
Last inspected
11 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7410852 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B3255
225065
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-225065

Inspections, by type

…with no type recorded18
Years with a record 9 calendar years (1986–2006)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16591 - Regulatory (Subpart C or D), Gross Ton
26026 - Dead Weight, Ton
33515 - Displacement, Ton
10198 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

11 July 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2709510
10 July 2006 Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2707852
10 July 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2716050
6 July 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2703851
19 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1881011
30 July 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1860766
25 September 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 125669
21 August 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 281292
18 July 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 279571
5 January 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 363529
24 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 363159
20 December 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 490536
21 January 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 355734
3 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 348535
4 December 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 340691
31 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 438887
24 February 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328651
27 October 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312333
15 October 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 464354
5 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 308663
30 April 1986 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 498196

Deficiency record · 15

Engineering › Fuel Oil Service System › Hose
Issued 10 July 2006 Resolved
Water cooling line running to fuel oil purifier leaking excessively.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Water cooling line running to fuel oil purifier has been permanently repaired and tested to the satisfaction of a classification society surveyor.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 10 July 2006 Resolved
Mounting bolts missing from all three generators in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Missing mounting bolts for generators have been mounted and tightened to the satisfaction of the classification society surveyor.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 July 2006 Resolved
Marine sanitation device leaking from undetermined location.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Leak from marine sanitation device has been stopped. Sewage unit pump''s mechanical seal was renewed. Marine sanitation device is now operating to the satisfaction of the classification society surveyor.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 July 2006 Resolved
Main diesel engine, engine room deck plates, and engine room bilge covered in oil; Poses fire and safety hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Main diesel engin, engine room, and engine room bilge have been cleaned to the satisfaction of a classification society surveyor. In addition, the leaks that were the sources of the excess oil have been identified and rectified.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 July 2006 Resolved
Purifier room containment area filled with oil; Poses fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Fuel oil purifier containment area has been cleaned to the satisfaction of the classification society surveyor.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 10 July 2006 Resolved
Starboard manifold containment area contains standing oil residue (approximately three inches); MARPOL hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Starboard manifold containment area under lube oil pumps number 1 and 2 has been cleaned to the satisfaction of the classification society surveyor.
Construction/Loadline › Hull › Side Shell
Issued 10 July 2006 Resolved
Excessive scale/corrosion/pitting in side shell of engine room and exterior hull; Structural integrity in question.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Thickness tests have been performed on the corroded spots in question. The classification society surveyor has attested to the satisfactory thickness and temporary repairs of the spots in question.
Engineering › Freshwater Generation System › Piping
Issued 10 July 2006 Resolved
Soft patch on fresh water generator overboard discharge line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Fresh water generator overboard discharge line has been repaired to the satisfaction of the classification society surveyor, and has been tested under working pressure and found tight.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 July 2006 Resolved
Two soft patches on water line located on overhead, portside of the bottom most deck of the engine room, above main fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2006
Resolution: Air compressor water cooling line has been permanently repaired and tested to the satisfaction of the classification society surveyor.
Accommodation/Occupational Safety
Issued 18 July 2000 Resolved
CORRODED AND RUSTED AREA ON TOP OF TANK TO BE REPAIRD PRIOR TO 19AUG00. _x001C_ SOLAS 74 (UNAMMENDED) I-10
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Documentation
Issued 3 February 1992 Resolved
THE BOARDING OFFICER NOTED THE OIL RECORD BOOK WAS NOT SIGNED BY THE PIC _x001C_ AFTER EACH ENTRY.
Condition: Unknown
Due 3 March 1992
Resolved 5 February 1992
Navigation
Issued 4 December 1990 Resolved
VESSEL OVER 16OO GROSS TONS ENTERED US PORT SAVANNAH, GA WITH OUT DATED COPY OF US COAST PILOT VOLUME 4. A VIOLATION OF 33 CFR 164.33 (A)(2) (i)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Navigation
Issued 5 May 1986 Resolved
U.S. COAST PILOT NBR. 2 1986 EDITION ONBOARD WITHOUT CORRECTIONS AS REQUIRED BY 33 CFR 164.33
Condition: Unknown
Due 5 May 1986
Resolved 5 May 1986
Navigation
Issued 5 May 1986 Resolved
CHARTS 12333, 12334, 12349 NOT ONBOARD AS REQUIRED BY 33 CFR 164.33.
Condition: Unknown
Due 5 May 1986
Resolved 5 May 1986
Navigation
Issued 5 May 1986 Resolved
U.S. COAST GUARD LIGHT LIST VOL. I 1985 EDITION ONBOARD BUT NOT CORRECTED UP TO DATE A REQUIRED BY 33 CFR 164.33.
Condition: Unknown
Due 5 May 1986
Resolved 5 May 1986

Ownership record