← All vessels
EPIC STAR
EPIC STAR is a 1978 freight ship. The Coast Guard has recorded 17 inspections since 1985, most recently in October 2001, along with 82 deficiencies — 2 with no resolution recorded — and 3 operational controls.
Records from 1985 to 2001. Most recent: inspection, 4 October 2001.
- Built
- 1978
- Last inspected
- 4 October 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 82 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7410888 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HXN6
225068
Flag
LIBERIA
—
Maury page id
psix-225068
Inspections, by type
…with no type recorded16
…past their stated due date2
Years with a record
9 calendar years (1985–2001)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it165575 - Regulatory (Subpart C or D), Gross Ton
26098 - Dead Weight, Ton
8913 - Regulatory (Subpart C or D), Net Ton
26098 - Dead Weight, Ton
8913 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
4 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294401
23 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282598
2 August 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280827
1 August 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 638541
14 July 2000
Port Security Assessment
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 594632
2 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 107248
21 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279159
1 June 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 12016
30 May 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 278271
23 January 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 412160
7 January 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 411618
23 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399628
24 February 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 388172
25 January 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 334913
25 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 328149
10 December 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320121
15 March 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 301694
Deficiency record · 82
Engineering
Issued 4 October 2001
No resolution recorded
NO. 3 GENERATOR JACKET WATER PUMP SEAL IS LEAKING (SOLAS 74A I/11). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 4 October 2001
No resolution recorded
NO. 1 COMPRESSOR ON SEWAGE TREATMENT PLANT DOES NOT PROVIDE PRESSURE (33 CFR 159.7). MAKE PERMANENT REPAIRS PRIOR TO NEXT U.S. PORT.
Fire Fighting
Issued 4 October 2001
Resolved
SCBA UNITS (2) ARE NOT EQUIPPED WITH LOW PRESSURE ALARM (SOLAS 60 II-2/14).PROVIDE CLASS REPORT THAT GUAGE MEETS REQUIREMENT OF FLAG STATE, OR PROVIDERECEIPT OF SERVICE.
Unknown
Issued 23 September 2000
Resolved
TWO OUTSTANDING OVERDUE DF FROM HOUMS CASE PS00069633 (DF #05 AND #06).
Unknown
Issued 23 September 2000
Resolved
TWO DF REMAIN OUTSTANDING FROM NEWMS PS00066480 (#FE06, #FE07).
Electrical
Issued 23 September 2000
Resolved
EXCESSIVE FUEL LEAKS FROM ALL MAIN SHIP'S SERVICE GENERATOR FUEL INJECTORS.
Construction/Loadline
Issued 23 September 2000
Resolved
EXCESSIVE OILY WASTE IN E/R BILGE SPACES.
Documentation
Issued 23 September 2000
Resolved
GARBAGE RECORD BOOK NOT PROPERLY MAINTAINED.
Accommodation/Occupational Safety
Issued 23 September 2000
Resolved
MSD INOPERABLE & LEAKING.
Engineering
Issued 2 August 2000
Resolved
FUEL OIL DISCHARGE CONTAINMENT IN WAY OF #2&3 CARGO HOLDS STBD SIDE & ALL FUEL OIL & DRAIN TANKS AFT OF #5 CARGO HOLD WASTED & PLUGS MISSING 33CFR155.320 REPAIR CONTAINMENT ENCLOSURES & INSERT PLUGS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Fire Fighting
Issued 2 August 2000
Resolved
HOSES IN FIXED CO2 RM CONNECTING BOTTLES WITH DIST MANIFOLD DEGRADED & CO2 RELEASE CABLE IN ENTRY TO CO2 RM EXPOSED & HAZARDOUS BECAUSE OF POTENTIAL ACCIDENTAL DISCHARGE. SOLAS 60/CH2/58. HAVE HOSES SERVICED/REPLACED BY SERVICING COMPANY & MAKE CABLE PULLS SAFE TO SATISFACTION OF USCG M.I.
Engineering
Issued 2 August 2000
Resolved
BUNKER TANK VENTS IN WAY OF # 2&3 CARGO HOLD STBD SIDE AND AFT OF #5 CARGO HOLD MISSING PROPER SIZE FLAME SCREENS OR WASTED/COMPRIMISED FLAME SCREENS 33CFR111 REPLACE/REPAIR FLAME SCREENS ON VENTS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Lifesaving
Issued 2 August 2000
Resolved
FOWARD LIFERAFT HYDROSTATIC RELEASE HAS AN ILLEGIBLE EXPIRATION DATE & WEAKLINK IMPROPERLY POSITIONED. SOLAS 74(96AMD)III/13/4.2 REPLACE OR REMOVEHYDO RELEASE AND PROPERLY ARRANGE WEAKLINK TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Construction/Loadline
Issued 2 August 2000
Resolved
WEATHERTIGHT ACCESS DOOR TO FOWARD CRAIN WASTED AT KNIFE EDGE ILLC/66/16.4 ENSURE MEANS FOR SECURING WEATHERTIGHTNESS TO SATISFACTION OF CERTIFICATE ISSUNG AUTHORITY
Construction/Loadline
Issued 2 August 2000
Resolved
CRANE WALKWAYS WASTED & GUARD RAIL PORT SIDE FWD OF LIFE RAFT BROKE AT BASEOF AFT STANTION ILLC/66/15 REPLACE OR RENEW TO THE SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Engineering
Issued 14 July 2000
Resolved
#1 & #3 GENERATOR JACKET WATER PUMPS LEAKING
Engineering
Issued 14 July 2000
Resolved
PISTON COOLING PUMPS LEAKING FROM MECANICAL SEAL
Electrical
Issued 14 July 2000
Resolved
NEWMOUROUS MACHINERY CONTROL (ON /OFF SWITCH) NOT IN GOOD WORKING ORDER (MISSING SWITICHES)
Construction/Loadline
Issued 14 July 2000
Resolved
EMERGENCY GENERATOR COMPARTMENT HATCH WASTED
Navigation
Issued 14 July 2000
Resolved
RUDDER ANGLE INDICATOR ON BRIDGE STICKS AND NOT IN CALIBRATION WITH RUDDER
Accommodation/Occupational Safety
Issued 14 July 2000
Resolved
SEWAGE TANK HAS TEMP REPAIRS (PATCH) ON TANK
Engineering
Issued 14 July 2000
Resolved
AUX. START AIR COMPRESSOR HAS COOLING LEAKS
Construction/Loadline
Issued 14 July 2000
Resolved
EXCESSIVE STANDING OIL ON PIPES AND BILGES AROUND GENERATORS AND PURIFIERS FOR FUEL.
Documentation
Issued 14 July 2000
Resolved
PROVIDE CLASS REPORT ISSUED BY LR ON 7-12-00 9 TOTAL CONDITINS OF CLASS
Fire Fighting
Issued 14 July 2000
Resolved
FLYWHEEL GUARD ON EMERGENCY FIRE PUMP MISSING
Accommodation/Occupational Safety
Issued 14 July 2000
Resolved
ALL SHIPS TOILETS INSTALLED RUNNING WATER NOT WORKING. TOILETS FLUSHED WITHBUCKET OF WATER
Documentation
Issued 14 July 2000
Resolved
VESSEL HAS 12 CONDITIONS OF CLASS 7 OF WHICH MUST BE COMPLETE
Accommodation/Occupational Safety
Issued 14 July 2000
Resolved
GALLY, DRY STORES AND REFER INFESTED WITH ROACHES
Accommodation/Occupational Safety
Issued 14 July 2000
Resolved
RAW SEWAGE BACKING UP INTO CREWS CABINS
Lifesaving
Issued 14 July 2000
Resolved
GREASE TRAP IN GALLY FULL OF GREASE. VENT ABOVE TRAP DRIPPING WITH GREASE
Accommodation/Occupational Safety
Issued 14 July 2000
Resolved
CREW SLEEPING IN RACKS IN MAIN PASSAGEWAY BLOCKING MAIN PASSAGEWAY
Engineering
Issued 14 July 2000
Resolved
#3 GENERATOR LUBE OIL COOLER INLET PIPE HAS TEMPERAORY REPAIR.
Engineering
Issued 30 May 2000
Resolved
Bilge ejection valve handwheel missing
Fire Fighting
Issued 30 May 2000
Resolved
Vessel lacked proper firefighting stations near firemain
Electrical
Issued 30 May 2000
Resolved
EMERGENCY GEN. UNABLE TO CARRY LOAD
Fire Fighting
Issued 30 May 2000
Resolved
Paintlocker fixed firefighting system not proper labeled
Accommodation/Occupational Safety
Issued 30 May 2000
Resolved
Toilets throughout the vessel could not be flushed, the water was rationed to 01 hour per day.
Lifesaving
Issued 30 May 2000
Resolved
Port lifeboats throttle and cooling system rigged inproperly
Lifesaving
Issued 30 May 2000
Resolved
Port lifeboat muffler wasted and holed._x001C_
Engineering
Issued 30 May 2000
Resolved
Oily water seperator was bypassed, it was completely inoperable
Fire Fighting
Issued 30 May 2000
Resolved
Fire main leaking, not producing adequate water pressure.
Lifesaving
Issued 30 May 2000
Resolved
Lifelines on bridgewing lifebouys rigged wrong_x001C_
Unknown
Issued 30 May 2000
Resolved
Crew was unfarmiliar with the abandonship and fire drills
Lifesaving
Issued 30 May 2000
Resolved
batteries improperly stowed in radar equipment room
Lifesaving
Issued 30 May 2000
Resolved
provide suitable battery trays in proper area
Electrical
Issued 30 May 2000
Resolved
cooling water leak on Emergency gen.
Lifesaving
Issued 30 May 2000
Resolved
missing electrical matting in front of emergency switchboard
Accommodation/Occupational Safety
Issued 30 May 2000
Resolved
Crew bedding in front of main switch board, control room
Accommodation/Occupational Safety
Issued 30 May 2000
Resolved
engine room covered in excessive oil, fire hazard
Lifesaving
Issued 30 May 2000
Resolved
insuffiecent lifejackets in accordance [name withheld]. Cert.
Fire Fighting
Issued 30 May 2000
Resolved
repack fire pump shaft
Lifesaving
Issued 7 January 1998
Resolved
PROVIDE PROOF OF ISM CODE COMPLIANCE PRIOR TO JULY 1, 1998.
Fire Fighting
Issued 23 January 1997
Resolved
FIRE MAIN SUPPORTS ON MAIN DECK WASTED.(SOLAS 74(AMENDED)REG II-2/21).
Lifesaving
Issued 23 January 1997
Resolved
FLAMMABLE LIQUIDS IMPROPERLY STOWED IN STEERING GEAR FLAT. PROPERLY STOW FLAMMABLE LIQUIDS IN PAINT LOCKER. (SOLAS 60 REG II/54)
Engineering
Issued 23 January 1997
Resolved
MAKE PERMANENT REPAIRS TO "SOFT PATCHES" ON MAIN SALT WATER COOLING LINE FOR SHIP'S SERVICE GENERATORS LOCATED ON THE PORT SIDE BELOW GENERATOR FLAT. (SOLAS 74(AMENDED) REG II-1/26.
Engineering
Issued 23 January 1997
Resolved
NO.2 GENERATOR FRESH WATER PUMP LEAKING EXCESSIVELY FROM GASKETS.
Engineering
Issued 23 January 1997
Resolved
NO.3 GENERATOR LUBE OIL STRAINER LEAKING EXCESSIVELY.
Accommodation/Occupational Safety
Issued 23 January 1997
Resolved
MSD DISCHARGE PIPING HAS "SOFT PATCHES." MAKE PERMANENT REPAIRS.
Lifesaving
Issued 23 January 1997
Resolved
PORT AND STBD LIFEBOATS HAVE NO LIMIT SWITCHES. SOLAS 60 REG III/29(L).
Electrical
Issued 23 January 1997
Resolved
LIGHT COVERS MISSING THROUGHT OUT VESSEL. (ILO 147)
Fire Fighting
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING NEXT U.S. PORT, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF REPAIRS MADE TO FIREMAIN LOCATED ON MAIN DECK (MIDSHIP & STBD SIDE - FWD OF HOUSE).
Construction/Loadline
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE HULL MARKINGS (LOADLINE AND DRAFTMARKS) IN CONTRASTING COLORS TO HULL.
Engineering
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO PRESENT SERVICEABILITY OF MAIN ENGINE SEA WATER COOLING LINE (WHERE CEMENT BOX PATCH EXISTS).
Accommodation/Occupational Safety
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO PRESENT SERVICEABILITY OF SEWAGE OVERBOARD DISCHARGE LINE (WHERE CEMENT BOX PATCH EXISTS)._x001C_
Engineering
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONOF SERVICEABILITY FOR MAIN DIESEL GENERATOR SALTWATER COOLING LINE (6") (WHERE CEMENT BOX PATCH EXISTS).
Fire Fighting
Issued 24 February 1996
Resolved
PROVIDE PORTABLE FIRE EXTINGUISHERS AT STATIONS #10 AND #11 (WHERE MISSING).
Engineering
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF #2 GENERATOR SEAWATER COOLING LINE (WHERE RUBBER PATCH EXISTS).
Engineering
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF STEAM CONDENSATE COOLING SYSTEM (WHERE MULTIPLE TEMPORARY REPAIRS EXIST).
Navigation
Issued 24 February 1996
Resolved
PRIOR TO ENTERING NEXT U.S. PORT, ADJUST/REPAIR MAGNETIC COMPASS LOCATED ONBRIDGE AND PROVIDE CURRENT/ACCURATE DEVIATION TABLE.
Unknown
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE VALID INTERNATIONAL TONNAGE CERTIFICATE.
Engineering
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR OWS 1" PIPE RISER (90 DEGREE ELBOW), WHERE LEAKING.
Engineering
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF MAIN ENGINE COOLING LINE LOCATED ON 02 DECK OF ENGINE ROOM (WHERE DOUBLER EXISTS).
Engineering
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO OILY WATER SEPARATOR BILGE SUCTION LINE (WHER HOLED/PATCHED).
Fire Fighting
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF MAIN FIREPUMP DISCHARGE LINE (WHERE DOUBLER EXISTS).
Engineering
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE BELT GUARD FOR REFRIGERATION UNITCOMPRESSOR.
Accommodation/Occupational Safety
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR MSD PIPING SYSTEM WASTE COLLECTIONLINE (WHERE MULTIPLE LEAKS EXISTS).
Accommodation/Occupational Safety
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE COVERS FOR LIGHT FIXTURES LOCATEDIN AFTER STEERING.
Engineering
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF OILY WATER SEPARATOR TANK (WHERE WELDED TEMP REPAIR EXISTS).
Deck/Cargo
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR/REPLACE FLANGE ON SLOPS DISCHARGE STATION (WHERE WASTED).
Engineering
Issued 24 February 1996
Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF LUBE OIL RECEPTION LINE LOCATED AT TRANSFER STATION(WHERE MECH. PATCH EXISTS).
Accommodation/Occupational Safety
Issued 24 February 1996
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE IMO APPROVAL FOR TYPE II MSD.
Navigation
Issued 10 December 1987
Resolved
THE VESSEL DID NOT HAVE A COPY OF THE TIDAL CURRENT TABLES ONBOARD.