MAURY USCG vessel records Sign in
← All vessels

EPIC STAR

EPIC STAR is a 1978 freight ship. The Coast Guard has recorded 17 inspections since 1985, most recently in October 2001, along with 82 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1985 to 2001. Most recent: inspection, 4 October 2001.

Built
1978
Last inspected
4 October 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7410888 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225068
Flag
LIBERIA
—
Maury page id
psix-225068

Inspections, by type

…with no type recorded16
…past their stated due date2
Years with a record 9 calendar years (1985–2001)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it165575 - Regulatory (Subpart C or D), Gross Ton
26098 - Dead Weight, Ton
8913 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

4 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294401
23 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282598
2 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280827
1 August 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 638541
14 July 2000 Port Security Assessment
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 594632
2 July 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 107248
21 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279159
1 June 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 12016
30 May 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 278271
23 January 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 412160
7 January 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 411618
23 January 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 399628
24 February 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 388172
25 January 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 334913
25 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 328149
10 December 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320121
15 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 301694

Deficiency record · 82

Engineering
Issued 4 October 2001 No resolution recorded
NO. 3 GENERATOR JACKET WATER PUMP SEAL IS LEAKING (SOLAS 74A I/11). REPAIR TO THE SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 October 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 4 October 2001 No resolution recorded
NO. 1 COMPRESSOR ON SEWAGE TREATMENT PLANT DOES NOT PROVIDE PRESSURE (33 CFR 159.7). MAKE PERMANENT REPAIRS PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 10 October 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 4 October 2001 Resolved
SCBA UNITS (2) ARE NOT EQUIPPED WITH LOW PRESSURE ALARM (SOLAS 60 II-2/14).PROVIDE CLASS REPORT THAT GUAGE MEETS REQUIREMENT OF FLAG STATE, OR PROVIDERECEIPT OF SERVICE.
Condition: Unknown
Due 8 October 2001
Resolved 5 October 2001
Unknown
Issued 23 September 2000 Resolved
TWO OUTSTANDING OVERDUE DF FROM HOUMS CASE PS00069633 (DF #05 AND #06).
Condition: Unknown
Due 24 September 2000
Resolved 29 September 2000
Unknown
Issued 23 September 2000 Resolved
TWO DF REMAIN OUTSTANDING FROM NEWMS PS00066480 (#FE06, #FE07).
Condition: Unknown
Due 24 September 2000
Resolved 29 September 2000
Electrical
Issued 23 September 2000 Resolved
EXCESSIVE FUEL LEAKS FROM ALL MAIN SHIP'S SERVICE GENERATOR FUEL INJECTORS.
Condition: Unknown
Due 24 September 2000
Resolved 29 September 2000
Construction/Loadline
Issued 23 September 2000 Resolved
EXCESSIVE OILY WASTE IN E/R BILGE SPACES.
Condition: Unknown
Due 24 September 2000
Resolved 29 September 2000
Documentation
Issued 23 September 2000 Resolved
GARBAGE RECORD BOOK NOT PROPERLY MAINTAINED.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 23 September 2000 Resolved
MSD INOPERABLE & LEAKING.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Engineering
Issued 2 August 2000 Resolved
FUEL OIL DISCHARGE CONTAINMENT IN WAY OF #2&3 CARGO HOLDS STBD SIDE & ALL FUEL OIL & DRAIN TANKS AFT OF #5 CARGO HOLD WASTED & PLUGS MISSING 33CFR155.320 REPAIR CONTAINMENT ENCLOSURES & INSERT PLUGS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Condition: Unknown
Due 3 August 2000
Resolved 13 August 2000
Fire Fighting
Issued 2 August 2000 Resolved
HOSES IN FIXED CO2 RM CONNECTING BOTTLES WITH DIST MANIFOLD DEGRADED & CO2 RELEASE CABLE IN ENTRY TO CO2 RM EXPOSED & HAZARDOUS BECAUSE OF POTENTIAL ACCIDENTAL DISCHARGE. SOLAS 60/CH2/58. HAVE HOSES SERVICED/REPLACED BY SERVICING COMPANY & MAKE CABLE PULLS SAFE TO SATISFACTION OF USCG M.I.
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Engineering
Issued 2 August 2000 Resolved
BUNKER TANK VENTS IN WAY OF # 2&3 CARGO HOLD STBD SIDE AND AFT OF #5 CARGO HOLD MISSING PROPER SIZE FLAME SCREENS OR WASTED/COMPRIMISED FLAME SCREENS 33CFR111 REPLACE/REPAIR FLAME SCREENS ON VENTS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Condition: Unknown
Due 3 August 2000
Resolved 13 August 2000
Lifesaving
Issued 2 August 2000 Resolved
FOWARD LIFERAFT HYDROSTATIC RELEASE HAS AN ILLEGIBLE EXPIRATION DATE & WEAKLINK IMPROPERLY POSITIONED. SOLAS 74(96AMD)III/13/4.2 REPLACE OR REMOVEHYDO RELEASE AND PROPERLY ARRANGE WEAKLINK TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Construction/Loadline
Issued 2 August 2000 Resolved
WEATHERTIGHT ACCESS DOOR TO FOWARD CRAIN WASTED AT KNIFE EDGE ILLC/66/16.4 ENSURE MEANS FOR SECURING WEATHERTIGHTNESS TO SATISFACTION OF CERTIFICATE ISSUNG AUTHORITY
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Construction/Loadline
Issued 2 August 2000 Resolved
CRANE WALKWAYS WASTED & GUARD RAIL PORT SIDE FWD OF LIFE RAFT BROKE AT BASEOF AFT STANTION ILLC/66/15 REPLACE OR RENEW TO THE SATISFACTION OF CERTIFICATE ISSUING AUTHORITY
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Engineering
Issued 14 July 2000 Resolved
#1 & #3 GENERATOR JACKET WATER PUMPS LEAKING
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Engineering
Issued 14 July 2000 Resolved
PISTON COOLING PUMPS LEAKING FROM MECANICAL SEAL
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Electrical
Issued 14 July 2000 Resolved
NEWMOUROUS MACHINERY CONTROL (ON /OFF SWITCH) NOT IN GOOD WORKING ORDER (MISSING SWITICHES)
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Construction/Loadline
Issued 14 July 2000 Resolved
EMERGENCY GENERATOR COMPARTMENT HATCH WASTED
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Navigation
Issued 14 July 2000 Resolved
RUDDER ANGLE INDICATOR ON BRIDGE STICKS AND NOT IN CALIBRATION WITH RUDDER
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Accommodation/Occupational Safety
Issued 14 July 2000 Resolved
SEWAGE TANK HAS TEMP REPAIRS (PATCH) ON TANK
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Engineering
Issued 14 July 2000 Resolved
AUX. START AIR COMPRESSOR HAS COOLING LEAKS
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Construction/Loadline
Issued 14 July 2000 Resolved
EXCESSIVE STANDING OIL ON PIPES AND BILGES AROUND GENERATORS AND PURIFIERS FOR FUEL.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Documentation
Issued 14 July 2000 Resolved
PROVIDE CLASS REPORT ISSUED BY LR ON 7-12-00 9 TOTAL CONDITINS OF CLASS
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 14 July 2000 Resolved
FLYWHEEL GUARD ON EMERGENCY FIRE PUMP MISSING
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Accommodation/Occupational Safety
Issued 14 July 2000 Resolved
ALL SHIPS TOILETS INSTALLED RUNNING WATER NOT WORKING. TOILETS FLUSHED WITHBUCKET OF WATER
Condition: Unknown
Due 3 October 2000
Resolved 4 October 2001
Documentation
Issued 14 July 2000 Resolved
VESSEL HAS 12 CONDITIONS OF CLASS 7 OF WHICH MUST BE COMPLETE
Condition: Unknown
Due 30 November 2000
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 14 July 2000 Resolved
GALLY, DRY STORES AND REFER INFESTED WITH ROACHES
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Accommodation/Occupational Safety
Issued 14 July 2000 Resolved
RAW SEWAGE BACKING UP INTO CREWS CABINS
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Lifesaving
Issued 14 July 2000 Resolved
GREASE TRAP IN GALLY FULL OF GREASE. VENT ABOVE TRAP DRIPPING WITH GREASE
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Accommodation/Occupational Safety
Issued 14 July 2000 Resolved
CREW SLEEPING IN RACKS IN MAIN PASSAGEWAY BLOCKING MAIN PASSAGEWAY
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Engineering
Issued 14 July 2000 Resolved
#3 GENERATOR LUBE OIL COOLER INLET PIPE HAS TEMPERAORY REPAIR.
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Engineering
Issued 30 May 2000 Resolved
Bilge ejection valve handwheel missing
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 30 May 2000 Resolved
Vessel lacked proper firefighting stations near firemain
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Electrical
Issued 30 May 2000 Resolved
EMERGENCY GEN. UNABLE TO CARRY LOAD
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 30 May 2000 Resolved
Paintlocker fixed firefighting system not proper labeled
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Accommodation/Occupational Safety
Issued 30 May 2000 Resolved
Toilets throughout the vessel could not be flushed, the water was rationed to 01 hour per day.
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
Port lifeboats throttle and cooling system rigged inproperly
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
Port lifeboat muffler wasted and holed._x001C_
Condition: Unknown
Due 13 June 2000
Resolved 14 June 2000
Engineering
Issued 30 May 2000 Resolved
Oily water seperator was bypassed, it was completely inoperable
Condition: Unknown
Due 10 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 30 May 2000 Resolved
Fire main leaking, not producing adequate water pressure.
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
Lifelines on bridgewing lifebouys rigged wrong_x001C_
Condition: Unknown
Due 10 June 2000
Resolved 14 June 2000
Unknown
Issued 30 May 2000 Resolved
Crew was unfarmiliar with the abandonship and fire drills
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
batteries improperly stowed in radar equipment room
Condition: Unknown
Due 9 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
provide suitable battery trays in proper area
Condition: Unknown
Due 9 June 2000
Resolved 14 June 2000
Electrical
Issued 30 May 2000 Resolved
cooling water leak on Emergency gen.
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
missing electrical matting in front of emergency switchboard
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Accommodation/Occupational Safety
Issued 30 May 2000 Resolved
Crew bedding in front of main switch board, control room
Condition: Unknown
Due 10 June 2000
Resolved 14 June 2000
Accommodation/Occupational Safety
Issued 30 May 2000 Resolved
engine room covered in excessive oil, fire hazard
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Lifesaving
Issued 30 May 2000 Resolved
insuffiecent lifejackets in accordance [name withheld]. Cert.
Condition: Unknown
Due 12 June 2000
Resolved 14 June 2000
Fire Fighting
Issued 30 May 2000 Resolved
repack fire pump shaft
Condition: Unknown
Due 10 June 2000
Resolved 14 June 2000
Lifesaving
Issued 7 January 1998 Resolved
PROVIDE PROOF OF ISM CODE COMPLIANCE PRIOR TO JULY 1, 1998.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Fire Fighting
Issued 23 January 1997 Resolved
FIRE MAIN SUPPORTS ON MAIN DECK WASTED.(SOLAS 74(AMENDED)REG II-2/21).
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Lifesaving
Issued 23 January 1997 Resolved
FLAMMABLE LIQUIDS IMPROPERLY STOWED IN STEERING GEAR FLAT. PROPERLY STOW FLAMMABLE LIQUIDS IN PAINT LOCKER. (SOLAS 60 REG II/54)
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Engineering
Issued 23 January 1997 Resolved
MAKE PERMANENT REPAIRS TO "SOFT PATCHES" ON MAIN SALT WATER COOLING LINE FOR SHIP'S SERVICE GENERATORS LOCATED ON THE PORT SIDE BELOW GENERATOR FLAT. (SOLAS 74(AMENDED) REG II-1/26.
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Engineering
Issued 23 January 1997 Resolved
NO.2 GENERATOR FRESH WATER PUMP LEAKING EXCESSIVELY FROM GASKETS.
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Engineering
Issued 23 January 1997 Resolved
NO.3 GENERATOR LUBE OIL STRAINER LEAKING EXCESSIVELY.
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 23 January 1997 Resolved
MSD DISCHARGE PIPING HAS "SOFT PATCHES." MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 28 January 1997
Resolved 5 February 1997
Lifesaving
Issued 23 January 1997 Resolved
PORT AND STBD LIFEBOATS HAVE NO LIMIT SWITCHES. SOLAS 60 REG III/29(L).
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Electrical
Issued 23 January 1997 Resolved
LIGHT COVERS MISSING THROUGHT OUT VESSEL. (ILO 147)
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Fire Fighting
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING NEXT U.S. PORT, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF REPAIRS MADE TO FIREMAIN LOCATED ON MAIN DECK (MIDSHIP & STBD SIDE - FWD OF HOUSE).
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Construction/Loadline
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE HULL MARKINGS (LOADLINE AND DRAFTMARKS) IN CONTRASTING COLORS TO HULL.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Engineering
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO PRESENT SERVICEABILITY OF MAIN ENGINE SEA WATER COOLING LINE (WHERE CEMENT BOX PATCH EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Accommodation/Occupational Safety
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO PRESENT SERVICEABILITY OF SEWAGE OVERBOARD DISCHARGE LINE (WHERE CEMENT BOX PATCH EXISTS)._x001C_
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONOF SERVICEABILITY FOR MAIN DIESEL GENERATOR SALTWATER COOLING LINE (6") (WHERE CEMENT BOX PATCH EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Fire Fighting
Issued 24 February 1996 Resolved
PROVIDE PORTABLE FIRE EXTINGUISHERS AT STATIONS #10 AND #11 (WHERE MISSING).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF #2 GENERATOR SEAWATER COOLING LINE (WHERE RUBBER PATCH EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF STEAM CONDENSATE COOLING SYSTEM (WHERE MULTIPLE TEMPORARY REPAIRS EXIST).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Navigation
Issued 24 February 1996 Resolved
PRIOR TO ENTERING NEXT U.S. PORT, ADJUST/REPAIR MAGNETIC COMPASS LOCATED ONBRIDGE AND PROVIDE CURRENT/ACCURATE DEVIATION TABLE.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Unknown
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE VALID INTERNATIONAL TONNAGE CERTIFICATE.
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR OWS 1" PIPE RISER (90 DEGREE ELBOW), WHERE LEAKING.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Engineering
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF MAIN ENGINE COOLING LINE LOCATED ON 02 DECK OF ENGINE ROOM (WHERE DOUBLER EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO OILY WATER SEPARATOR BILGE SUCTION LINE (WHER HOLED/PATCHED).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Fire Fighting
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF MAIN FIREPUMP DISCHARGE LINE (WHERE DOUBLER EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Engineering
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE BELT GUARD FOR REFRIGERATION UNITCOMPRESSOR.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Accommodation/Occupational Safety
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR MSD PIPING SYSTEM WASTE COLLECTIONLINE (WHERE MULTIPLE LEAKS EXISTS).
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Accommodation/Occupational Safety
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE COVERS FOR LIGHT FIXTURES LOCATEDIN AFTER STEERING.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Engineering
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION AS TO SERVICEABILITY OF OILY WATER SEPARATOR TANK (WHERE WELDED TEMP REPAIR EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Deck/Cargo
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, REPAIR/REPLACE FLANGE ON SLOPS DISCHARGE STATION (WHERE WASTED).
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Engineering
Issued 24 February 1996 Resolved
PRIOR TO DEPARTING PORT OF MOREHEAD CITY, PROVIDE CLASS SOCIETY ATTESTATIONAS TO SERVICEABILITY OF LUBE OIL RECEPTION LINE LOCATED AT TRANSFER STATION(WHERE MECH. PATCH EXISTS).
Condition: Unknown
Due 25 February 1996
Resolved 26 February 1996
Accommodation/Occupational Safety
Issued 24 February 1996 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE IMO APPROVAL FOR TYPE II MSD.
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Navigation
Issued 10 December 1987 Resolved
THE VESSEL DID NOT HAVE A COPY OF THE TIDAL CURRENT TABLES ONBOARD.
Condition: Unknown
Due 10 December 1987
Resolved 10 December 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.