← All vessels
DA LUO SHAN
DA LUO SHAN is a 1976 freight ship. The Coast Guard has recorded 21 inspections since 1985, most recently in March 1998, along with 43 deficiencies and 1 operational control.
Records from 1985 to 1998. Most recent: inspection, 30 March 1998.
- Built
- 1976
- Last inspected
- 30 March 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 43 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7411478 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
BRQA
225080
Flag
PANAMA
—
Maury page id
psix-225080
Inspections, by type
…with no type recorded21
Years with a record
11 calendar years (1985–1998)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it36119 - Regulatory (Subpart C or D), Gross Ton
63980 - Dead Weight, Ton
22935 - Regulatory (Subpart C or D), Net Ton
63980 - Dead Weight, Ton
22935 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
30 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 414238
20 December 1997
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 76071
8 December 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411123
29 March 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376615
23 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 686467
11 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 356149
25 November 1992
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 354818
14 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 686466
8 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 537810
2 December 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 347363
16 September 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 495887
9 September 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 537446
30 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 340562
12 July 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 331140
19 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036596
18 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 323031
23 December 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1000376
6 October 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 311840
26 September 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 311634
1 July 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 522272
12 October 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 304711
Deficiency record · 43
Deck/Cargo
Issued 29 March 1995
Resolved
Make permanent repairs to the leaking deck hydraulic systems prior to departure per 33 C.F.R. 155.10(b). Reference PSNS for locations.
Lifesaving
Issued 29 March 1995
Resolved
Replace the belt drive covers in the following locations; 1) water pumps, (drinking), two guards, 2) Fuel oil transfer pump drive in the purifier room, 3) A\C machinery drives, two guards. Complete prior to departure perSOLAS Chapter II-1 Reg 26(1).
Lifesaving
Issued 29 March 1995
Resolved
Remove all stored paint from the engine room to the ships approved paint locker, prior to departure, per SOLAS Chapter II-2 Reg 18(7).
Fire Fighting
Issued 29 March 1995
Resolved
Prove proper operation of the following fire doors; 1) remove hold backs from all stairway doors, 2) Port engine room entrance has a hold back device, 3) lower level engine room escape door won't close properly. Complete prior to departure per SOLAS Chapter ii-2 Reg 47(2)._x001C_
Deck/Cargo
Issued 29 March 1995
Resolved
Repair the patched and leaking hydraulic line in the forward deck stores over the stairs, prior to return to a U.S. port, per SOLAS Chapter II-1 Reg. 26(1).
Fire Fighting
Issued 29 March 1995
Resolved
Verify all weather deck fire main valves have handles. Six were noted missing during boarding. Correct prior to departure per SOLAS Chapter II-2Reg 4.
Navigation
Issued 29 March 1995
Resolved
Make permanent repairs to the two, badly leaking hydraulic pumps on the steering gear, prior to departure, per SOLAS Chapter II-1 Reg 29.
Navigation
Issued 29 March 1995
Resolved
Provide cotter pin locks on the four control linkage joints on the steeringgear, prior to departure, per USCG MSM Volume II 14.b.1.e._x001C_ _x001C_
Navigation
Issued 29 March 1995
Resolved
Remove the rubber hoses from the steering gear hydraulic oil fill pump. Hard pipe the system using steel or similar materials. Complete prior to departure per SOLAS Chapter II-1 Reg 26(12.3).
Unknown
Issued 29 March 1995
Resolved
Repair the badly leaking #2 hydraulic pump in the engine room, prior to departure, per SOLAS Chapter II-1 reg 26(1).
Engineering
Issued 29 March 1995
Resolved
Make permanent repairs to the patched fuel line on the #2 purifier, prior to departure, per SOLAS Chapter II-1 Reg 26(1).
Engineering
Issued 29 March 1995
Resolved
Repair the valves on the oil heat exchanger in the purifier space to prevent oils from draining onto the electrical controllers, prior to departure, per SOLAS Chapter II-1 Reg 26(1).
Engineering
Issued 29 March 1995
Resolved
Provide a cover for the electrical box on the oily water separator control box, prior to departure, per SOLAS Chapter II-1 Reg 40(1.3).
Accommodation/Occupational Safety
Issued 29 March 1995
Resolved
Remove the air duct from the engine room excape tower. Permanently patch the associated hole in the bulkhead of the engine room control space. Complete prior to departure per SOLAS Chapter II-2 Reg 45.
Lifesaving
Issued 29 March 1995
Resolved
Permanently mount the high pressure gas cylinders by the A/C machinery_x001C_ (no ropes) prior to departure per SOLAS Chapter II-1 Reg 26(1).
Electrical
Issued 29 March 1995
Resolved
Replace or repair all lighting in the engine room at the locations listed in the PSNS, prior to departure, per SOLAS Chapter II-1 reg 41(2.1).
Electrical
Issued 29 March 1995
Resolved
Repair the wasted port light on the water tight door to the galley, stbd side. Complete prior to departure per ICLL Chapter II reg 12.
Electrical
Issued 29 March 1995
Resolved
Clean the paint off and prove the proper operation of the stbd bunker station light, prior to departure, per 33 C.F.R. 155.790.
Fire Fighting
Issued 29 March 1995
Resolved
Permanently repair the deck firemain in the following locations:_x001C_ 1) port side, aft of #2 hatch where patched and where joint is leaking,_x001C_ 2) port sided, aft of #3 hatch where wasted and holed. Complete prior to return to a U. S. port per SOLAS Chapter II-2 Reg 4. (item 2; #1 done)_x001C_
Engineering
Issued 29 March 1995
Resolved
Make permanent repairs to the wasted engine room piping prior to return to a U. S. port per SOLAS Chapter II-1 Reg 26(1). Reference PSNS for locations.
Lifesaving
Issued 29 March 1995
Resolved
Clean the excessive oil throughout the engineroom prior to return to a U. S. port per SOLAS Chapter II-2 Reg 2. Reference PSNS for locations._x001C_ _x001C_ (Only main bilges remain to be cleaned)
Engineering
Issued 29 March 1995
Resolved
Remove the auxiliary gas boiler feed water hose and replace with a permanent piping system, prior to departure, per SOLAS CH II-1 Reg 26(1).
Electrical
Issued 29 March 1995
Resolved
Replace the emergency generator fuel hose with an approved fuel hose, (class approved), prior to departure, per SOLAS Chapter II-1 Reg 26(1).
Accommodation/Occupational Safety
Issued 29 March 1995
Resolved
Remove all food from the emergency generator space, prior to departure, perILO-147.
Lifesaving
Issued 29 March 1995
Resolved
Replace both wasted embarkation ladders to the life boats, prior to departure, per SOLAS Chapter III Reg 11(7).
Construction/Loadline
Issued 29 March 1995
Resolved
Permanently repair the three stbd side main deck vent closures that are frozen, prior to departure, per ICLL Chapter II Reg 19(4).
Accommodation/Occupational Safety
Issued 29 March 1995
Resolved
Replace the wasted step to the forward deck house entrance, prior to departure, per ILO-147.
Navigation
Issued 29 March 1995
Resolved
Permanently repair the starboard, forward power ram on the steering gear. It is leaking excessively. Complete prior to departure per SOLAS Chapter II-1 Reg 29.
Electrical
Issued 29 March 1995
Resolved
Make permanent repairs to the following electrical hazards; 1) three dead ended wires on the steering gear, 2) port steering gear control panel wiresdead ended, 3) purifier room light improperly wired and junction box open. Complete prior to departure per SOLAS Chapter II-1 Reg 40(1.3).
Documentation
Issued 11 February 1993
Resolved
OIL TRANSFER PROCEDURES WERE NOT COMPLETE AND THEY WERE NOT IN A LANGUAGE THE CREW COULD UNDERSTAND.
Navigation
Issued 11 February 1993
Resolved
CHART 11361, 11364, 11368 AND 11370 FOR THE AREA TO BE TRANSITTED WERE NOT CURRENTLY CORRECTED.
Unknown
Issued 11 February 1993
Resolved
THE VESSEL WAS SUSPECTED OF DISPOSING ALL OF IT'S GARBAGE INCLUDING PLASTICS IN THE WATER, WHICH IS A VIOLATION OF MARPOL 73/78 ANNEX V.
Navigation
Issued 25 November 1992
Resolved
33 CFR 164.37(a) Vessel's secondary radar was not operable as required by 33 CFR 164.11(r).
Navigation
Issued 25 November 1992
Resolved
33 CFR 164.38(b) Vessel's arpa was not operational as required by 33 CFR 164.11(r).
Accommodation/Occupational Safety
Issued 25 November 1992
Resolved
33 CFR 151.67 Vessel's personnel stated that they dump all garbage, including plastics, overboard. Vessel's garbage log indicated last disposal of plastic was just outside of the United States Exclusive Economic Zone. No waste management plan.
Navigation
Issued 30 November 1990
Resolved
VESSEL HAS AN OUTDATED TIDAL CURRENT TABLES.
Navigation
Issued 30 November 1990
Resolved
VESSEL HAS OUTDATED CHARTS. CHARTS #11412,11413,11414 HAVE NOT BEEN CORRECTED SINCE 1988.
Navigation
Issued 12 July 1989
Resolved
VESSEL FAILED TO HAVE CURRENTLY CORRECTED COAST GUARD LIGHT LIST CFR 164.33(A)(2)(II)
Navigation
Issued 12 July 1989
Resolved
VESSEL FAILED TO HAVE CURRENTLY CORRECTED U.S. COAST PILOT VOL. 5 CFR 164.33(A)(2)(I)
Navigation
Issued 12 July 1989
Resolved
VESSEL FAILED TO HAVE CURRENTLY CORRECTED NAVIGATIONAL CHARTS 11361, 11364 FOR THE AREA TRANSITED. CFR 164.33 (A)(1)(II)
Navigation
Issued 12 October 1985
Resolved
VESSEL FAILED TO PROPERLY MAINTAINE EQUIPMENT AS REQUIRED.
Navigation
Issued 12 October 1985
Resolved
VESSEL HAD ONLY ONE OPERATIONAL RADAR.
Navigation
Issued 12 October 1985
Resolved
VESSEL FAILED TO NOTIFY THE COTP OF A INOPERTIVE RADAR.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.