Records from 1984 to 2005. Most recent: operational control imposed, 12 July 2005.
Inspection history · 72
12 July 2005
Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2424280
12 July 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2424467
6 March 2005
Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2305682
4 March 2005
PI Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2301259
2 March 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2302017
25 February 2005
ILO-147 Exam · Ballast Water Examination · ISPS III Exam · PI Safety Exam · ISM Exam · STCW 95 Exam · Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2299227
14 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2275016
13 January 2005
Ballast Water Examination · PI Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2271818
11 January 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2272884
11 January 2005
Type not recorded
No type recorded · GROUP HAMPTON ROADS · USCG East District (CGD-E) · Activity 2277348
23 December 2004
Loadline Exam · PI Safety Exam · ISM Exam · STCW 95 Exam · Ballast Water Examination · ILO-147 Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2264120
25 July 2004
PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2146650
24 July 2004
ILO-147 Exam · MARPOL Annex V Examination · STCW 95 Exam · MARPOL Annex I Examination · PII Safety Exam · Loadline Exam · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2141155
30 January 2004
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1997546
12 November 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1946583
10 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1930981
10 October 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1933433
6 August 2003
Annual Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1868757
30 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1862348
30 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1862368
28 January 2003
MARPOL Annex V Examination · Ballast Water Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1737462
22 January 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1734841
17 January 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1731833
17 January 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1731859
28 October 2002
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1709274
22 July 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1650407
29 June 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1640706
10 April 2002
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination · Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1603168
3 July 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291566
22 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286388
11 July 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279844
15 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278114
12 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 433690
13 September 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 723150
31 August 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 432483
3 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 429325
1 May 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 428160
21 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427869
18 November 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 422802
9 September 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420279
15 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 414884
25 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 408190
24 April 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 402882
2 April 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 389668
1 May 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 377690
31 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 374606
26 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 368918
26 July 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 870573
7 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 358655
22 April 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357911
7 March 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 356770
9 May 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 350624
9 January 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 348159
11 December 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340789
4 May 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 907795
16 April 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 483488
2 February 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 930280
12 December 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 334232
29 June 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 515132
12 December 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 327311
21 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 530846
3 December 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 319965
5 October 1987
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 470121
11 May 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 489304
30 April 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 534013
21 January 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1007260
12 November 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313114
4 October 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 311825
2 September 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 445498
16 December 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305890
3 July 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 483436
5 December 1984
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 299237
Engineering › Steering Gear System › Motor
Issued 12 July 2005
Resolved
#1 steering gear motor was inoperable. Vessel must replace or repair motor. Installation must be approve by Coast Guard approved Class society or Flag representative.
Action required: 705 - Other - as specified
Due 12 July 2005
Resolved 15 July 2005
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 12 July 2005
No resolution recorded
Vessel has an auxiliary generator permanently installed aboard vessel. Installation must be approved by a Coast Guard approved Class society or flag rep.
Action required: 705 - Other - as specified
Due 12 August 2005 — due date passed with no resolution recorded
Engineering › Feedwater/Condensate Water System › Piping
Issued 12 July 2005
Resolved
Salt water cooling leaks on Port main engine and both generators
Action required: 705 - Other - as specified
Due 12 August 2005
Resolved 15 July 2005
Operations/Management › Ballast Water Managment › Submission of Report
Issued 12 July 2005
Resolved
During the vessels vyoage to the U.S. which started December 2004, the vessel failed to submit a ballast water report to the NBIC
Due 12 July 2005
Resolved 12 July 2005
Resolution: Issued NOV
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 March 2005
Resolved
Vessel is missing (1) section of railing on the main deck STBD side amidships.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Received class report from DNV surveyor on behalf of Panamanian Maritime Authority verifying that proper repairs have been made to the missing deck railing.
Lifesaving › Lifebuoys › Immediately Available
Issued 4 March 2005
Resolved
Vessel does not have a quick release mechanism on either port or stbd bridgewings for the lifebouys.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Received report from DNV surveyor on behalf of Panamanian Maritime Authority requiring the vessel to have quick release mechanisms for the smoke signals on the bridge wings installed before next US port call but not later then 15 Apr 2005.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 14 January 2005
Resolved
After Captain failed a sobriety test on 11JAN05. The Captain on 14JAN05 was arrested and removed from the vsl. The vsl was no longer in compliance with their Safe Manning doc. Flag Admin must provide written verification that the Captain is competent to be responsible for & can operate the vsl. SOLAS detention placed on vessel IAW SOLAS 74 Chapter XI-I Regulation 4 and STCW 78 Regulation I/4.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 January 2005
Resolution: Deep South Shipping (the operator) assigned a new Captain to operate the vessel
Fire Fighting › Firemans Outfit › Gloves
Issued 13 January 2005
Resolved
Provide a new set of fire-fighting gloves for fireman's outfit in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: Class report states a new set of gloves has been acquired.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 13 January 2005
Resolved
Provide 05 new water lights for life jackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: Class reports states life jacket lights are replaced
Communications › Internal Communications System › Portable Radios
Issued 13 January 2005
Resolved
Provide 03 new batteries for 03 GMDSS handheld radios.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2005
Resolution: Class report states the batteries for the hand held GMDSS radios have been replaced.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 13 January 2005
Resolved
Replace all retro-reflective material on both lifeboats, crews lifejackets, and all life bouys
Action required: 705 - Other - as specified
Due 14 February 2005
Resolved 12 February 2005
Resolution: Class report states all retro-reflective material has been replaced.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 13 January 2005
Resolved
Provide a ship specific Ballast Water Management Plan. A letter of warning (LOW) will be issued.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 February 2005
Resolution: Class report states a specific Ballast Water Management Plan has been implemented. Verified by Coast Guard inspection team.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 13 January 2005
Resolved
Replace lagging on boiler piping.
Action required: 705 - Other - as specified
Due 14 February 2005
Resolved 12 February 2005
Resolution: Class report states lagging in boiler piping has been replaced.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 13 January 2005
Resolved
Replace pressure guage on #1 generator.
Action required: 705 - Other - as specified
Due 14 February 2005
Resolved 12 February 2005
Resolution: Class states pressure gauge has been replaced.
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 13 January 2005
Resolved
Properly label loadline on vessel in accordance with loadline certificate.
( Remove ABS on starboard side. )
Action required: 705 - Other - as specified
Due 14 February 2005
Resolved 12 February 2005
Resolution: Class report states loadline has been replaced.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 23 December 2004
Resolved
Vessel operating without [name withheld] is standing a Port and Starboard watch rotation which conflicts with SOLAS standards. [name withheld] will arrive in Brunswick on 26DEC04.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Lifesaving › Lifeboat › Inherent Buoyancy
Issued 23 December 2004
Resolved
Following Life Boat drills, both lifeboats were raised and when cradled, the davit blocks damaged the keel of the life boats.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 23 December 2004
Resolved
Stbd main engine alarm panel is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 December 2004
Resolved
S/W cooling piping from the stbd L/O cooler to the port L/O cooler has numerous holes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Diesel Engine (auxiliary) › Crankshaft
Issued 23 December 2004
Resolved
RPM gauges for M/E's and genrators are inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Compressed Air System (control) › Compressor
Issued 23 December 2004
Resolved
L/O leak on deck air compressor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 23 December 2004
Resolved
Stbd generator has L/O leak from head gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Compressed Air System (control) › Compressor
Issued 23 December 2004
Resolved
Deck air compressor is permanently wired into ship electrical system without class approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 23 December 2004
Resolved
S/W piping to toilet holed and has patch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 23 December 2004
Resolved
Sewage overboard pipe is holed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Documentation › Markings/Placards › Injury Placard
Issued 23 December 2004
Resolved
Vessel missing IMO sticker for emergency equipment.
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 December 2004
Resolved
Stbd reduction gear missing control oil pressure gauge.
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 December 2004
Resolved
Vessel fire control plan does not address fire boundaries.
Action required: 705 - Other - as specified
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 23 December 2004
Resolved
Install fuel piping for port and stbd main engines in accordance with SOLAS 74A CH II-2, Reg. 15.2.9.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 23 December 2004
Resolved
Audible power loss alarm for steering on bridge is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2004
Resolved 7 January 2005
Resolution: Item cleared.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 23 December 2004
Resolved
Vessel has non intrinsically safe light switch in paint locker.
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Lifesaving › Lifeboat Equipment › Sea-anchor
Issued 23 December 2004
Resolved
Port side lifeboat has wasted sea anchor.
Action required: 705 - Other - as specified
Due 6 January 2005
Resolved 7 January 2005
Resolution: Item cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 July 2004
Resolved
15 ppm oily water separator inoperable. Owner states new unit on order, to be delivered & installed in Panama ,and tested to the satisfaction of Class Society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 23 December 2004
Resolution: Item cleared.
Fire Fighting › International Shore Connection › Bolts
Issued 24 July 2004
Resolved
Bolts, nuts & washers missing from Int'l Shore Connection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 23 December 2004
Resolution: Item cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 July 2004
Resolved
Fire Control Plan doesn't show class A & B boundaries, and is missing a visible means of access to several spaces.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 23 December 2004
Resolution: Item not cleared. Resissued deficiency to be cleared prior to departure.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 July 2004
Resolved
Emergency escape ladders (2) from engine room, partially blocked by electrical cords and chains. Items removed immediately, corrected on the spot.
Condition: Improper/Lack of Maintenance
Due 24 July 2004
Resolved 24 July 2004
Resolution: Items removed from ladders, corrected immediately.
Electrical › Lighting (service) › Switch
Issued 24 July 2004
Resolved
Restricted spaces #12 & #13 contain light fixtures, cable runs, and switches that present electricasl shock hazzards to crew personnel. Repair NLT than 24Aug04.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2004
Resolved 23 December 2004
Resolution: Item cleared.
Documentation › Certificates/Documents
Issued 12 November 2003
Resolved
Expired Solas Safety Construction Certificate 31 OCT 03/PMDS. Solas 74 I/12,14
Vessel is detained in the Port of Chickasaw until the vessel has been satisfactorily inspected and issued a SOLAS Safety Construction Certificate. Vessel is detained under SOLAS. LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Action required: 705 - Other - as specified
Resolved 30 January 2004
Resolution: Solas Safety Construction Certificate is valid until 12May04.
Operations/Management › Drills/Instruction
Issued 20 August 2003
Resolved
Crew could not demonstrate proper fire drill. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Crew demonstrated a proper fire drill.
Fire Fighting › Firemans Outfit
Issued 20 August 2003
Resolved
The vessel's fireman's outfit has one empty SCBA bottle, which renders it incomplete.
Recharge bottle prior to departure.
LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Vessel has sufficient SCBA bottles.
Documentation › Manifests/Lists
Issued 20 August 2003
Resolved
The muster list is incorrect. The muster list shows the [name withheld] as wearing the fireman's outfit, but during drill the AB wore the fireman's outfit. Correct muster list to show crew members actual duties.
LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying the muster list was corrected.
Engineering › Steering Gear System
Issued 20 August 2003
Resolved
The steering indicator lights on the bridge do not operate properly. Prove proper operation prior to movement to satisfaction of class. LEGACY COMPONENT DESC: Indicating lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 9 September 2003
Resolution: Verified proper operation of steering indicator lights and loss of steering alarms.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The starboard main engine wiring is incomplete and not properly secured.
LEGACY COMPONENT DESC: Engine wiring
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Verified proper wiring for starboard main engine.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The starboard main engine has fuel leaks on the fuel injection pumps of cylinders 1, 3 and 4.
LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Verified repairs with no fuel leaks detected.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The starboard main engine has a cooling water leak on the No. 6 cylinder head.
LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2003
Resolved 9 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The starboard main engine injection box drains directly to the bilge in violation of 33 CFR 155.770. Re-pipe to the waste oil tank as required.
LEGACY COMPONENT DESC: Injection box drains
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying the injection box drains were routed to the waste oil tank.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The starboard main engine has an oil leak at the No. 4 cylinder rocker arm. LEGACY COMPONENT DESC: Rocker arm lubrication
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Verified repairs with no oil leak detected.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003
Resolved
The port main engine has a cooling water leak on the No. 6 cylinder head
LEGACY COMPONENT DESC: Cylinder Head
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 20 August 2003
Resolved
The starboard generator is missing the protective lagging at the exhaust uptake.
LEGACY COMPONENT DESC: Exhaust System
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying repairs were completed.
Pollution Prevention/Response › Prevention Equipment
Issued 20 August 2003
Resolved
There is excessive garbage on the weather decks. Properly stow garbage, so that it will not fall overboard and then have all garbage removed from the vessel. Additionally,provide invoice of disposal to U.S. Coast Guard.
LEGACY COMPONENT DESC: Garbage
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Engineering › Bilge Water Management System
Issued 20 August 2003
Resolved
There is excessive oil in the engine room bilge. Make bilges clean and dry and ensure that there is sufficient storage capacity in the waste oil tank to maintain it that way.
LEGACY COMPONENT DESC: bilges
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Oil was removed from the bilge and stored in drums.
Deck/Cargo › Mooring/Anchoring
Issued 20 August 2003
Resolved
Both the port and starboard anchor windlasses are in poor condition. Provide class report attesting to the integrity of each windlass and its foundation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2003
Resolved 9 September 2003
Resolution: Windlasses were operationally tested by class and found satisfactory.
Lifesaving › Lifejacket/PFD (General)
Issued 20 August 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 9 September 2003
Resolution: A new lifejacket was purchased and placed onboard for the [name withheld].
Documentation › Safety/Response Plans/Programs
Issued 20 August 2003
Resolved
The fire safety and control plan are not up to date. The plan shows a new paint locker with water sprinkler forward of the No. 2 cargo hold vice the CO2 protected space forward of the No.1 cargo hold. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 30 October 2003
Resolution: Updated and verified by class.
Operations/Management › Port and Waterways Safety
Issued 20 August 2003
Resolved
Provide detailed written testing procedure, following the manufacturer's guidelines and approved by class, for the testing of the starboard main engine.
LEGACY COMPONENT DESC: Repair / testing procedure
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 9 September 2003
Resolution: Provided a detailed written testing proceedure, approved by class, for the testing of the starboard main engine.
Personnel › Manning/Qualifications
Issued 6 August 2003
Resolved
The vessel does not have the required number of deck officers onboard. Provide appropriately certificated deck officer onboard prior to departure. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: A properly certificated 2nd officer arrived on the vessel.
Personnel › Certificates/Documents/Licenses
Issued 6 August 2003
Resolved
The Chief Engineer does not have a flag state endorsement for his license or documentary proof that one has been applied for. LEGACY COMPONENT DESC: STCW Endorsement
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: The Chief Engineer receieved documentary proof that he has applied for a flag state endorsement .
Documentation › Certificates/Documents
Issued 6 August 2003
Resolved
The vessel does not have the original Safety Management Certificate onboard as required. LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: Original SMC now on board.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 August 2003
Resolved
The vessel's starboard main engine does not operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: The starboard main engine is now operable.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 August 2003
Resolved
The vessel's port main engine has a unusual noise coming from the #4 cylinder and does not appear to operate at full capabilities. Provide technician's report proving proper operation prior to departure. Additionally, the vessel must have tug(s) of adequate horsepower standing by while at anchorage
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 7 August 2003
Resolution: Received tech report from Coastal [name withheld] stating that the Port main engine was repaired and tested with satisfactory results.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 6 August 2003
Resolved
The vessel's diesel generators were secured and only lighting was being supplied by a portable deck generator. The vessel had no propulsion, fire fighting water or navigation capabilities readily available. One generator must be kept running and providing power at all times while at anchorage.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 6 August 2003
Resolution: Both generatorss were tested and one was left on line satisfying requirement.
Engineering › Sea-water System (primary cooling)
Issued 6 August 2003
Resolved
The salt water cooling pipe to the main engine has a large rubber patch by way of the bilge and fire pumps. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: The salt water cooling pipe repairs were verified.
Fire Fighting › Fire Main
Issued 6 August 2003
Resolved
The engine room fire main piping has several pinhole leaks and is severely corroded throughout. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: The fire main piping has been repaired.
Deck/Cargo › Holds/Tanks
Issued 6 August 2003
Resolved
The No.1 cargo hold has doubler patch that is wasted and holed on the forward portside coaming. LEGACY COMPONENT DESC: Coaming
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying repairs were completed.
Construction/Loadline › Structures
Issued 6 August 2003
Resolved
AB cabin that occupies forward port side of main deck level has hole in bulkhead underneath of porthole. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: Hole repaired.
Fire Fighting › Fire Main
Issued 6 August 2003
Resolved
The fire main pipe at the forward of cargo deck has hose banded to the end of it and is not listed on the fire control plan as a fire station. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS accepting this arrangement.
Fire Fighting › International Shore Connection
Issued 6 August 2003
Resolved
The International Shore Connection is painted to bulkhead and cannot be readily removed.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: Now readily available.
Fire Fighting › Structural Fire Protection - General
Issued 6 August 2003
Resolved
The bulkhead between the galley and the steering compartment hatch is wasted and holed. Permanently repair. LEGACY COMPONENT DESC: Cooking Area
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying repairs were completed.
Lifesaving › Inflatable Liferafts
Issued 6 August 2003
Resolved
The starboard life raft is permanently lashed to vessel with the hydrostatic release disconnected. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 20 August 2003
Resolution: Hydrostatic release properly installed.
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 6 August 2003
Resolved
The galley, dry stores and vessel accommodation is infested with insects.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: Suficient fumagation was completed.
Documentation › Logs/Records
Issued 6 August 2003
Resolved
The vessel is not recording their garbage discharges to shore side. Vessel must record all discharges to shore even if there is no reception facility receipt. LEGACY COMPONENT DESC: Garbage Record keeping
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 22 August 2003
Resolution: Received class report from PMDS verifying that the log has been updated and the crew has been instructed to follow the listed instructions.
Pollution Prevention/Response › Response Equipment
Issued 6 August 2003
Resolved
The oil spill equipment does not have non sparking shovels as required. LEGACY COMPONENT DESC: Non-sparking Hand Scoops/Shovels/Buckets
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 20 August 2003
Resolution: Acceptable shovel provided.
Operations/Management › Vessel Safety Management
Issued 6 August 2003
Resolved
Objective evidence was observed during the inspection that the vessel's Safety Management System is not in compliance with the ISM Code. The vessel is to have an external audit of the Safety Management System conducted by the flag state or a recognized organization acting on behalf of flag state. LEGACY COMPONENT DESC: External Certification/Verification/Control
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: An audit was conducted by class. See narrative
Operations/Management › Drills/Instruction
Issued 6 August 2003
Resolved
Because of the overall poor material condition of the vessel the examination could not be completed. The vessel must complete a Port State Control Annual examination to include fire and abandon ship drills prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 August 2003
Resolved 9 September 2003
Resolution: A satisfactory Annual examination was conducted.
Pollution Prevention/Response › Prevention Equipment
Issued 6 August 2003
Resolved
Crew must remove all garbage and provide invoice to MSO New Orleans prior to departure from port. LEGACY COMPONENT DESC: Garbage
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2003
Resolved 9 October 2003
Resolution: The vessel provided receipt as required this date.
Pollution Prevention/Response › Prevention Equipment
Issued 6 August 2003
Resolved
Vessel's crew must remove all waste oil that is stored in drums from the vessel and provide invoice to MSO New Orleans prior to departure from port. LEGACY COMPONENT DESC: Waste oil drums
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2003
Resolved 19 September 2003
Resolution: Received Delivery ticket from ASCO oil verfying removal of used oil.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 6 August 2003
Resolved
The starboard generator oil cooler inlet cooling pipe has a pinhole leak. LEGACY COMPONENT DESC: Oil Cooling
Action required: 15 - Rectify deficiencies by next port
Due 9 September 2003
Resolved 30 January 2004
Resolution: pinhole leak fixed and PMDS surveyed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 August 2003
Resolved
The Port Main Engine has a cooling water leak on #6 cylinder. LEGACY COMPONENT DESC: Cylinder
Action required: 15 - Rectify deficiencies by next port
Due 9 September 2003
Resolved 30 January 2004
Resolution: leak on #6 cylinder on main engine was fixed. PMDS surveyed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 August 2003
Resolved
Provide PMDS report closing out condition of class for the final operational testing of the main engines and diesel generators to cognizant USCG Captain of the Port NLT 30 October 2003. LEGACY COMPONENT DESC: Operational Testing
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 January 2004
Resolution: PMDS provided a report for final testing of the main engines and diesel generators.
Deck/Cargo › Mooring/Anchoring
Issued 6 August 2003
Resolved
Provide PMDS report closing out condition of class for the general maintenance of the Port and Starboard anchor windlasses to cognizant USCG Captain of the Port NLT 30 October 2003. LEGACY COMPONENT DESC: Port and Starboard Anchor Windlasses
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 January 2004
Resolution: PMDS provided report for general maintenance of the port and stbd anchor windlass.
Documentation › Safety/Response Plans/Programs
Issued 6 August 2003
Resolved
Provide PMDS report closing out condition of class for the final approval of Fire Safety and Control plan to cognizant USCG Captain of the Port NLT 30 October 2003. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 30 January 2004
Resolution: PMDS provided report for final approval of fire safety control plan.
Documentation › Certificates/Documents
Issued 28 January 2003
Resolved
PROVIDE PROOF OF VALID SMC SURVEY AND DOCUMENTATION. LEGACY COMPONENT DESC: Safety Management Certificate (ISM)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2003
Personnel › Certificates/Documents/Licenses
Issued 28 January 2003
Resolved
PROVIDE PROOF OF APPLICATION FOR OFFICERS FLAG STATE LICENSES. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2003
Engineering › Steering Gear System
Issued 28 January 2003
Resolved
REPLACE OR REPAIR REMOTE SWITCH TO STEERING GEAR PUMP #2. LEGACY COMPONENT DESC: Power Unit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2003
Fire Fighting › Fixed Deck Foam System
Issued 28 January 2003
Resolved
CLEAN AND LABEL INSTRUCTION ON FOAM FIREFIGHTING SYSTEM.
Condition: Improper/Lack of Maintenance
Due 28 January 2003
Resolved 29 January 2003
Personnel › Certificates/Documents/Licenses
Issued 22 July 2002
Resolved
ORDINARY SEAMAN (1) LICENSE UNAVAILABLE FOR REVIEW. PROVIDE MINIMUM REQUIRED CREW IN ACCORDANCE WITH SAFE MANNING DOCUMENT. LEGACY COMPONENT DESC: MMD, Ordinary Seaman
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2002
Resolution: O.S. PROVIDED COMPETENCY CERTIFICATE FROM PHILIPINES. MINIMUM CREW REQUIRMENT NOW MET.
Personnel › Certificates/Documents/Licenses
Issued 22 July 2002
Resolved
PROVIDE FLAG STATE LICENSES FOR ALL PERSONNEL ON BOARD.
Due 30 July 2002
Resolved 31 July 2002
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Cargo Transfer/Lightering
Issued 22 July 2002
Resolved
UPDATE OIL TRANSFER PROCEDURES TO REFLECT CURRENT CREW ON BOARD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2002
Resolution: OIL TRANSFER PROCEDURES REFLECT CURRENT CREW ABOARD VESSEL
Engineering › Generator (propulsion-electric)
Issued 22 July 2002
Resolved
PERMANENTLY REPAIR FUEL OIL COOLER OF NUMBER ONE GENERATOR BY ATTACHING TO THE MAIN GENERATORS BLOCK.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2002
Resolution: FUEL OIL COOLER ATTACHED TO #1 GENERATOR''S MAIN BLOCK
Engineering › Diesel Engine (auxiliary)
Issued 10 April 2002
No resolution recorded
Make neccessary repairs to #1 generator RPM gauge and demonstrate proper operation.l LEGACY COMPONENT DESC: Overspeed Device
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: RPM REPAIRED
Navigation › Piloting/Steering
Issued 10 April 2002
No resolution recorded
Provide updated navigational charts for areas of operation. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: UPDATED CHARTS PRESENTED
Navigation › Piloting/Steering
Issued 10 April 2002
Resolved
Provide current magnetic compass deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 15 April 2002
Resolution: CLEARED.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 April 2002
No resolution recorded
Securely mount all portable fire extingushers throughout vessel. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: ALL EXTINGUISHERS ARE PROPERLY/SAFELY MOUNTED
Engineering › Bilge Water Management System
Issued 10 April 2002
No resolution recorded
Replace all vital systems PVC piping in engine room with steel piping. (Bilge suction piping to OWS and bilge air purge pipe) LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: PVC HAS BEEN REPLACED WITH STEEL
Documentation › Certificates/Documents
Issued 10 April 2002
No resolution recorded
Provide Flage State surveyor statement of fact that the OWS operates properly and is installed in accordance with manufacturers standards. Also, prove filtering/separating system meets MARPOL Annex I.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: RECEIVED FLAG STATE APPROVAL OF OWS
Stability › Watertight Integrity
Issued 10 April 2002
No resolution recorded
Blank off through hull piping from aft steering to engineering space which compromises watertight integrity. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: PIPING HAS BEEN BLANKED
Lifesaving › Launching Appliances
Issued 10 April 2002
No resolution recorded
Port side forward lifeboat davit sheave is frozen - prove proper operation. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: SHEAVE HAS BEEN FREED
Engineering › Steering Gear System
Issued 10 April 2002
No resolution recorded
Provide solenoid valve push pins which actuate hydraulic valves under power from the steering flat. LEGACY COMPONENT DESC: Solenoid Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: A PERMANENTLY MOUNTED AND DEDICATED HAND TOOL HAS BEEN INSTALLED
Operations/Management › Drills/Instruction
Issued 10 April 2002
No resolution recorded
Amend emergency steering istructions to include proper operation of push pins required to operate steering in electro-hydraulic mode from the steering flat. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: NEW INSTRUCTIONS FOR EMERGENCY STEERING HAVE BEEN POSTED
Electrical › Lighting (service)
Issued 10 April 2002
No resolution recorded
Provide missing glass fixure for engine room light aft of port engine in the overhead. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: GLASS REPLACED
Personnel › Training
Issued 10 April 2002
No resolution recorded
Demonstrate satisfactory fire drill in the presence of US Coast Guard Marine Inspectors. LEGACY COMPONENT DESC: Familiarization Training
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2002 — due date passed with no resolution recorded
Resolution: CREW DEMONSTRATED SATISFACTORY FIRE DRILL
Electrical › Electrical Distribution System (service)
Issued 9 April 2002
No resolution recorded
Replace missing electrical face plate at junction box in fromt of the switch panel in the the engine room, starboard side. LEGACY COMPONENT DESC: Junction Box
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2002 — due date passed with no resolution recorded
Resolution: NEW FACE PLATE INSTALLED
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2002
No resolution recorded
Provide safety padding and safety tape on low overhead pipes at top of ladder leading out of lower engine room deck. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2002 — due date passed with no resolution recorded
Resolution: SAFETY PADDING INSTALLED
Documentation › Certificates/Documents
Issued 9 April 2002
Resolved
Provide Flage State documentation that all conditions of class listed on Safety Construction Certificate have been dealt with and corrected. LEGACY COMPONENT DESC: Cargo Ship Safety Construction Certificate
Condition: Unknown
Due 15 December 2002
Resolved 30 January 2004
Resolution: Vessel has no outstanding requirements.
Documentation › Certificates/Documents
Issued 9 April 2002
Resolved
Provide Flag State documentation that all conditions of class listed on the Safety Equipment Certificate have been dealt with and corrected. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Condition: Unknown
Due 30 June 2002
Resolved 28 October 2002
Resolution: All conditions of class noted on the Interim safety Equipment Certificate were corrected. Report onboard attesting that these items were addressed/corrected satisfactorily.
Documentation › Certificates/Documents
Issued 9 April 2002
No resolution recorded
Provide Flage State documentation that all outstanding Coast Guard deficiencies listed on boarding report of inspection Form B, dated 09APR02 have been satisfactorily completed.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2002 — due date passed with no resolution recorded
Resolution: FLAG STATE REPORT ATTESTING TO CORRECTION OF DEFICIENCIES WAS PROVIDED
Fire Fighting
Issued 3 July 2001
Resolved
EMERGENCY FIRE PUMP (DIESEL POWERED) INOPERABLE.
Condition: Unknown
Due 10 July 2001
Resolved 16 July 2001
Engineering
Issued 3 July 2001
Resolved
VESSELS FUEL OIL VENT CONTAINMENT AND BUNKERING MANIFOLD CONTAINMENT MISSING MECHANICAL PLUGS.
Condition: Unknown
Due 10 July 2001
Resolved 11 July 2001
Documentation
Issued 3 July 2001
Resolved
VESSEL HAS INVALID SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 10 July 2001
Resolved 11 July 2001
Electrical
Issued 3 July 2001
Resolved
EMERGENCY BATTERIES STOWED IMPROPERLY ON DECK.
Condition: Unknown
Due 10 July 2001
Resolved 11 July 2001
Navigation
Issued 3 July 2001
Resolved
VESSEL'S GMDSS INSTALLATION NOT COMPLETE.
Condition: Unknown
Due 10 July 2001
Resolved 11 July 2001
Construction/Loadline
Issued 3 July 2001
Resolved
EXCESSIVE OIL IN ENGINE ROOM BILGES.
Condition: Unknown
Due 10 July 2001
Resolved 16 July 2001
Fire Fighting
Issued 15 May 2000
Resolved
#1 FIRE PUMP LEAKING EXCESSIVELY FROM PACKING GLAND._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 18 May 2000
Resolved 22 May 2000
Documentation
Issued 15 May 2000
Resolved
MINIMUM SAFE MANNING CERT NOT VALID FOR VESSELS LAST VOYAGE._x001C_ _x001C_ SOLAS 74(A) V/13A_x001C_
Condition: Unknown
Due 18 May 2000
Resolved 22 May 2000
Documentation
Issued 15 May 2000
Resolved
NO STCW FOR VESSELS REQ: DECK OFFICER, GMDSS OPERATOR, AND ENGINEER._x001C_ _x001C_ SOLAS 74(A) V/13A_x001C_ STCW 95 11/1
Condition: Unknown
Due 18 May 2000
Resolved 22 May 2000
Documentation
Issued 15 May 2000
Resolved
ONE LIFE RAFT REQUIRED BY SAFETY EQUIPMENT CERT, MISSING._x001C_ _x001C_ SOLAS 60 CHAP I REG 19_x001C_
Condition: Unknown
Due 18 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 15 May 2000
Resolved
FIREMAIN PIPING NEAR #1 FIRE PUMP RUPTURED/REMOVED/MISSING._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 18 May 2000
Resolved 22 May 2000
Documentation
Issued 31 August 1999
Resolved
Safety Radio Telephone Certificate not available.
Condition: Unknown
Due 31 August 1999
Resolved 3 September 1999
Documentation
Issued 31 August 1999
Resolved
Classification Document not available.
Condition: Unknown
Due 31 August 1999
Resolved 3 September 1999
Documentation
Issued 31 August 1999
Resolved
The vessel's Load Line Certificate did not have the required annual endorsement.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 31 August 1999
Resolved
The vessel's SOLAS Safety Construction Certificate did not have the required annual endorsement.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 31 August 1999
Resolved
The vessel is not manned IAW with its Minimum Safe Manning Certificate.
Condition: Unknown
Due 13 October 1999
Resolved 13 October 1999
Lifesaving
Issued 31 August 1999
Resolved
Lack of evidence that the Liferafts have been service in the last 12 months.
Condition: Unknown
Due 2 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 31 August 1999
Resolved
Required drills, Fire and Abandon Ship, not properly logged.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 31 August 1999
Resolved
Emergency Fire Pump did not satisfactory start.
Condition: Unknown
Due 3 September 1999
Resolved 8 September 1999
Fire Fighting
Issued 31 August 1999
Resolved
Required Fire and Abandon Ship Drills were not satisfactory.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Navigation
Issued 31 August 1999
Resolved
Failure to log pre-arrival test conducted 12 hours prior to entering port.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Engineering
Issued 21 April 1999
Resolved
THE VESSELS STARBOARD GENERATOR SET LEAKS FUEL OIL. REQUIRED BY SOLAS 74 REG II-2/33(a).
Condition: Unknown
Due 4 June 1999
Resolved 4 June 1999
Lifesaving
Issued 21 April 1999
Resolved
PORT LIFEBOAT DOESN'T PROPERLY LOWER; BRAKE INOPERATIVE; DOESN'T FREELY MOVE IN DAVIT TRACKS. REQUIRED BY SOLAS 60 REG III/4(c).
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Engineering
Issued 21 April 1999
Resolved
THE PORT SALT WATER COOLING PUMP SHAFT PACKING LEAKS EXCESSIVELY. REQUIRED BY SOLAS 74(amended) REG II-1/26.
Condition: Unknown
Due 2 May 1999
Resolved 2 May 1999
Fire Fighting
Issued 18 November 1998
Resolved
Repair starboard Engine Room Fire Main Line Valve, that were seized and missing it's handle.
Condition: Unknown
Due 21 December 1998
Resolved 3 December 1998
Fire Fighting
Issued 18 November 1998
Resolved
Remove the Straight Stream Fire Nozzles and replace with Combination Nozzles in Engine room.
Condition: Unknown
Due 21 November 1998
Resolved 3 December 1998
Fire Fighting
Issued 18 November 1998
Resolved
Prove operation of the emergency fire pump.
Condition: Unknown
Due 21 November 1998
Resolved 3 December 1998
Electrical
Issued 18 November 1998
Resolved
Repair fuel oil leak from high pressure lines on starboard Ship Service Generator.
Condition: Unknown
Due 21 November 1998
Resolved 3 December 1998
Documentation
Issued 9 September 1998
Resolved
Prior to departure, provide valid Safety Construction Certificate.
Condition: Unknown
Due 10 September 1998
Resolved 25 September 1998
Lifesaving
Issued 9 September 1998
Resolved
Prior to departure, provide onboard vessel manning in accordance with the requirements of the Safe Manning Document in way of the First Mate.
Condition: Unknown
Due 10 September 1998
Resolved 25 September 1998
Electrical
Issued 24 April 1997
Resolved
Provide cover for electircal covers for junction boxes in engine room, remove breaker bar outlet that is temporarily wired tied in the paint locker also place a cover on the junction box that is in the paint locker.
Condition: Unknown
Due 24 July 1997
Resolved 25 April 1997
Lifesaving
Issued 24 April 1997
Resolved
Provide proper fire and boat drill for USCG inspectors.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Lifesaving
Issued 24 April 1997
Resolved
Provide monthly inspection of lifeboats using checklist and make proper_x001C_ log entry.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 26 July 1994
Resolved
CHARTS OF THE AREA TRANSITED, 11362, 11364, AND 11368 WERE NOT CURRENTLY CORRECTED. CHARTS WERE ALSO MISSING CORRECTIONS FOR 90 AND 92 YEARS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Navigation
Issued 26 July 1994
Resolved
US COAST PILOT 5 HAD NO CORRECTIONS. US COAST PILOT ONBOARD WAS 92 ED.
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Navigation
Issued 26 July 1994
Resolved
VESSEL'S US LIGHT LIST VOL IV HAD NO CORRECTIONS. VESSEL'S LIGHT LIST WAS 92 ED.
Condition: Unknown
Due 29 July 1994
Resolved 1 August 1994
Electrical
Issued 26 July 1994
Resolved
PROVIDE CLOSURE DEVICE FOR SHORE CONNECTION DISTRIBUTION BOX. _x001C_ SOLAS II-1.45.10
Condition: Unknown
Due 26 August 1994
Resolved 28 July 1994
Fire Fighting
Issued 26 July 1994
Resolved
FIRE MAIN NOT OPERABLE DUE TO REPAIRS. SOLAS II-1.4.1
Condition: Unknown
Due 1 August 1994
Resolved 29 July 1994
Electrical
Issued 26 July 1994
Resolved
PROVIDE GLOBES FOR LIGHTS IN STEERING ROOM. SOLAS II-1.45.10
Condition: Unknown
Due 26 August 1994
Resolved 29 July 1994
Documentation
Issued 26 July 1994
Resolved
PROVIDE HEALTH EXAM CERTIFICATES FOR ALL CREW MEMBERS. _x001C_ ILO 147 RES 73(1946)
Condition: Unknown
Due 26 August 1994
Resolved 29 July 1994
Construction/Loadline
Issued 2 February 1990
Resolved
MAINTAIN TEMPORARY REPAIRS TO DECK AREA IN WAY OF STBD LIFEBOAT FWD DAVIT LEG UNTIL PERMANENT REPAIRS ARE MADE.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Lifesaving
Issued 2 February 1990
Resolved
PROVIDE ON BOARD 2 LIFERAFTS, OF AT LEAST 10 PERSON CAPACITY, ON THE STBD SIDE OF VESSEL UNTIL PERMANENT REPAIRS ARE MADE TO DAVITS AND LIFEBOAT RENEWED.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Accommodation/Occupational Safety
Issued 4 October 1986
Resolved
VESSEL DID NOT HAVE AN OPERABLE COAST GUARD APPROVED MARINE SANITATION DEVICE ON BOARD AS REQUIRED BY 33CFR159.7. VESSELS TYPE III MSD HAD PIPINGTHAT BY-PASSED THE MSD AND DISCHARGED RAW SEWAGE OVERBOARD.
Condition: Unknown
Due 4 October 1986
Resolved 4 October 1986
Navigation
Issued 4 October 1986
Resolved
VESSEL DID NOT HAVE CURRENT CHART #11347 ON BOARD IAW 33CFR164.33.
Condition: Unknown
Due 4 October 1986
Resolved 4 October 1986
Fire Fighting
Issued 16 December 1985
Resolved
PROVIDE MARKINGS ON WEATHERTIGHT CONTAINER FOR EMERGENCY FIRE PLANS: "FIRE PLANS"
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985