MAURY USCG vessel records Sign in
← All vessels

CALYPSO I

CALYPSO I is a 1977 freight ship. The Coast Guard has recorded 76 inspections since 1984, most recently in April 2009, along with 66 deficiencies and 6 operational controls.

Records from 1984 to 2009. Most recent: inspection, 11 April 2009.

Built
1977
Last inspected
11 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7413751 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225116
Flag
PANAMA
—
Maury page id
psix-225116

Inspections, by type

…with no type recorded61
Years with a record 23 calendar years (1984–2009)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11817 - Convention (Subpart B), Net Ton
38845 - Dead Weight, Ton
30880 - Displacement, Ton
18602 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 76

11 April 2009 PI Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3447048
10 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3446449
15 January 2009 Ballast Water Examination · MARPOL Annex I Examination · PI Safety Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3393329
2 June 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3224814
19 October 2007 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3078702
27 October 2005 Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2523440
19 October 2005 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2517560
11 April 2005 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2331091
2 April 2005 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2325101
2 April 2005 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2325105
13 July 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2131956
1 July 2004 ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2117651
29 June 2004 PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2114673
29 June 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2118832
10 November 2003 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1945447
25 July 2003 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1859284
25 July 2003 Type not recorded
No type recorded · Station Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1920655
15 July 2003 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1847132
22 November 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1707159
15 November 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1705850
4 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1484685
8 November 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 295503
30 August 2001 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 293279
2 August 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 291925
9 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 162776
2 January 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 285351
5 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 434382
23 September 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 433065
24 August 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 431903
7 December 1998 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 423734
4 July 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 417526
4 January 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 411430
2 January 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 411344
2 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 725149
2 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 725150
1 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 725146
1 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 725147
1 October 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 725148
17 September 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 407858
5 July 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 405275
23 April 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 402656
19 April 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 402844
24 October 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 396487
15 October 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 396434
10 October 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 396177
3 July 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 392760
12 September 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 382745
11 July 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 380442
2 May 1995 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 377542
24 April 1995 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 377620
14 April 1995 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 378598
20 December 1994 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 373356
10 December 1994 Damage Survey
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1374175
12 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 370470
12 September 1994 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 690739
12 September 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865880
20 June 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 367718
20 June 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1021204
12 May 1993 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 357767
20 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 690740
4 January 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 464962
27 May 1992 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 350845
26 August 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 649056
19 August 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 345465
18 April 1990 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 336680
16 April 1990 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 336248
11 March 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 328998
25 January 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 449990
26 September 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 325833
18 July 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 324605
1 July 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 324276
2 April 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 322447
29 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 322137
22 September 1986 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 311386
15 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 303054
12 July 1984 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 296941

Deficiency record · 66

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 April 2009 Resolved
Chief Engineer notified PSCO that OCM display is currently not working. Chief Engineer noted problem on 10 APR 2009 during routine inspections, has properly notified company, and is expecting technician this port of call. PSCO verified and Oil [name withheld] confirms that the vessel has more than enough capacity remaining in bilge holding tanks for the next voyage.
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 15 April 2009
Resolution: Received technician work order stating that Oil Content Meter was repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 January 2009 Resolved
On the #1 Auxiliary Engine, there is a soft patch on the discharge pipe for the cooling water and it is actively leaking.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 January 2009
Resolved 11 April 2009
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 15 January 2009 Resolved
The PSCO found numerous minor lube oil leaks on Main Engine and the crew is currently managing the leaks.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 January 2009
Resolved 11 April 2009
Resolution: Received Class report stating that leaks have been identified and repairs have been made.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 2 June 2008 Resolved
Vessel's #3 aux. engine is leaking fuel oil from the #5 high pressure fuel pump injection line. Vessel must repair the leak prior to departure from the Port of Houston, TX to the satisfaction of the Certificate Issuing Authority. SOLAS 74 (2004 Cons. ED) Ch II-1/ Reg. 26
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2008
Resolved 3 June 2008
Resolution: Received class report attesting that the #3 Aux engine #5 high pressure fuel pump injection line was reportedly repaired by vessel crew. Systems were tested and found do be satisfactory.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 19 October 2007 Resolved
The vessel does not have oil transfer procedures in accordance with 33 CFR 155.750. The vessel is restricted from conducting bunkering operations in U.S waters until procedures have been submitted, reviewed, and approved by U.S Coast Guard.
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Resolved 2 June 2008
Resolution: Reviewed vessel''s oil transfer procedures.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 11 April 2005 Resolved
Vessel's echo depth sounder tranducer is inoperable.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2005
Resolution: 19 OCT 05 Class sent survey report updating Cargo Ship Safety Equipment Certificate. Echo depth sounder transducer is operable. Surveyor was contacted via phone by [name withheld]; all repairs are confirmed.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 29 June 2004 Resolved
VESSEL AGOUND AT PIER. VSL MUST PROVIDE USCG A DIVE SURVEY REPORT ON THE AREA OF THE HULL AFFECTED BY THE GROUNDING(BOW), AND PROVIDE CLASS(ABS) REPORT ATTESTING TO THE VSL FITNESS FOR ROUT AND SERVICE. USCG APPROVAL OF AFOREMENTIONED IS REQUIRED. (SOLAS 74 CH I REG. 11)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Recieved proper class report rearding the hull inspection, COTP Order was recinded.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 June 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Faulty units replaced and class report received.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 29 June 2004 Resolved
DEAD END WIRING, COMING FROM CONTRILER IN STEERING GEAR ROOM NEAR LADDER TO EMERGENCY FIRE PUMP, IS NOT PROPERLY TERMINATED . VSL MUST PROPERLY TERMINATE OR REMOVE THIS WIRING AND PROVIDE USCG A COPY OFR NON-CONFORMITY REPORT TO DPA ATTESTING TO PROPER REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Wiring removed, class report received.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 29 June 2004 Resolved
NEW INSTALLATION OF SECURITY LIGHTS ON THE FIRCASTLE REQUIRED THE PASSING OF WIRES THROUGH BULKHEADS BETWEEN BOS'N STORES, PAINT LOCKER, AND WEATHER DECKS. THE PENETRATIONS DO NOT MAINTAIN AN A-0 FIRE INTEGRITY RATING REQUIRED FOR A SERVICE SPACE OF HIGH RISK AS PER SOLAS. VSL MUST REPAIR INPROPER INSTALLATION AND PROVIDE CLASS REPORT TO USCG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 2 July 2004
Resolution: Repairs completed and class report received.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 June 2004 Resolved
BILGE ALARM IN AFT END OF ENGINE ROOM NOT FUNCTIONING. VSL MUST REPAIR ALARM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 29 June 2004
Resolution: Item was corrected prior to the conclusion of the boarding.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 June 2004 Resolved
TYPE II MSD WAS FOUND SECURED WITH BY-PASS VALVE AND OVERBOARD VALVE OPEN TO THE SEA, DISCHARGING UNTREATED SEWAGE INTO THE EAST RIVER VIOLATING 33CFR 159 AND 40 CFR 140.3. VSL MUST IMMEDIATELY STOP DISCHARGE OF SEWAGE, AND HAVE CLASS ATTEST TO THE PROPER OPERATION OF THE MSD AND PROVIDE REPORT TO USCG. VSL MUST ENSURE THAT ADEQUATE FACILITIES ARE PROVIDED FOR THE CREW UNTIL MSD IS ON LINE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Received proper class report attesting to the function of the system.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 29 June 2004 Resolved
Vessel had MSD by-pass piping. Vessel needs to provide proof from the vessel's classification society (ABS) or an attending Coast Guard Marine Inspector that the vessel's MSD is working properly. Prior to satisfactory proof of the proper operation of the MSD, an alternative means of maintaining sewage on board the vessel must be proposed, approved and put immediately into operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Vessel has provided a satisfactory report from Class.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Report of Potential Vessel Casualty
Issued 29 June 2004 Resolved
Vessel grounded. A commercial dive company survey report verifying the satisfactory condition of the vessel's hull, and a class surveyor's report from the vessel's classification society (ABS) that certifies the vessel for it's intended route and service, must be provided.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2004
Resolution: Vessel provided satifactory reports.
Fire Fighting › Self-contained Breathing Apparatus
Issued 10 November 2003 Resolved
Prove proper operation of the fireman's breathing apparatus. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Operations/Management › Drills/Instruction
Issued 10 November 2003 Resolved
Complete abandon ship drill to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Abandon Ship
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Operations/Management › Drills/Instruction
Issued 10 November 2003 Resolved
Complete fire drill to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 10 November 2003 Resolved
Properly lock out sewage overboard discharge valve. (completed prior to finishing the inspection).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 November 2003
Construction/Loadline › Structures › Door
Issued 10 November 2003 Resolved
Have class inspect all watertight doors and provide report as to their proper working condition, proper to returning to U.S. waters. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2005
Resolution: 19 Oct 05 As per Class Report Vsl crew has made all repairs to all water tight doors.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 November 2003 Resolved
Prove proper operation of all life jacket battery powered lights. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2003
Fire Fighting › Emergency Fire Pumps
Issued 22 November 2002 Resolved
Emeregency fire pump to be working properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2002
Resolution: Pump was repaired onboard.
Engineering
Issued 2 August 2001 Resolved
Prove proper operation of OWS to class or attending Coast Guard inspector prior to operating in U.S. navigable waters.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Fire Fighting
Issued 2 August 2001 Resolved
Emergency fire pump- Make repairs to fwd pump (air ejector). Coupling broken. Repair to satisfaction of class (pump operated @5 bars).
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Lifesaving
Issued 2 August 2001 Resolved
Port lifeboat (1) patch stbd lifeboat (2) patches have calss approve previous repairs to both lifeboats. (Port l/b patch cracked)
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Lifesaving
Issued 2 August 2001 Resolved
Vessel to provide adequate food rations for both stbd and port lifeboats. Five additional rations needed. Fax receipt to USCG Baltimore.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Lifesaving
Issued 2 August 2001 Resolved
Class to attest to repairs to bottom handrail on starboard lifeboat.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Deck/Cargo
Issued 2 August 2001 Resolved
Repair leaks on #6 crane to the satisfaction of ICGB. Crane not to be operated until repairs to the satisfaction of ICGB are completed.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Electrical
Issued 2 August 2001 Resolved
Class to address proper operation of ship's generators - ship lost power for approx. 10 minutes during boarding-possible overheating.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Accommodation/Occupational Safety
Issued 2 August 2001 Resolved
"Fish" freezer inoperative. make repairs to satisfaction of attending USCGmarine inspector. (Temp store using meat freezer sat)
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Unknown
Issued 2 August 2001 Resolved
No.2 air compressor has small crack on head(fwd) leaking water. Replace tothe satisfaction of class.
Condition: Unknown
Due 2 August 2001
Resolved 7 August 2001
Deck/Cargo
Issued 2 August 2001 Resolved
Four inch fracture at base of #1 crane on port side. Fracture has been temporarily repaired and remains an outstanding condition of the vessel's Class. No. 1 crane is to remain out of service until perminate repairs aremade.
Condition: Unknown
Due 8 November 2001
Resolved 14 November 2001
Navigation
Issued 2 January 2001 Resolved
REPAIR STEERING GEAR TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 2 February 2001
Resolved 2 February 2001
Engineering
Issued 2 January 2001 Resolved
INSTALL GUARD AROUND ROTATING SHAFT ON DIESEL GENERATOR FRESHWATER AND DIESEL GENERATOR SALTWATER PUMPS.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 24 August 1999 Resolved
Weak link on liferaft to be installed on STBD side.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 2 January 1998 Resolved
Exhaust leak noted from emergency fire pump diesel prime mover IWO exhaust manifold.
Condition: Unknown
Due 2 January 1998
Resolved 2 January 1998
Lifesaving
Issued 2 January 1998 Resolved
Globes & guards for lighting missing in fan room. Correct prior to next_x001C_ U.S. voyage but NLT 15Feb98. Recommend vsl not to be boarded as a _x001C_ priority II solely as a discrepancy follow-up for this item.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 2 January 1998 Resolved
Vsl's secondary fire pump (cargo bilge pump) in engineroom unable to deliver water pressure to firemain. Cloggage in piping appears to be_x001C_ cause of problem. Chief Engineer addressing. Requirment written for discrepancy to be corrected prior to departure from NPOC - Savannah, Ga.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Lifesaving
Issued 17 September 1997 Resolved
Chief Mate of vessel had alcohol on his breath which led to a breathalizer test under 33 C.F.R. 95.035. test indicated a BAC of .02 which is violationof above law.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Lifesaving
Issued 17 September 1997 Resolved
Third Mate had alcohol on his breath, which led to a breathalizer test under 33 C.F.R. 95.035. Test indicated a BAC of .07, which is in violationof above law. Confirmatory testing at N.Y. State police barracks revealed BAC of .23.
Condition: Unknown
Due 19 September 1997
Resolved 1 October 1997
Lifesaving
Issued 17 September 1997 Resolved
Master of vessel had alcohol on his breath which led to a breathalizer testunder 33 CFR 95.035. Test indicated a BAC of .05 which is in violation of above law. Confirmatory testing at N.Y. State police barracks revealed BAC of .03.
Condition: Unknown
Due 19 September 1997
Resolved 19 September 1997
Lifesaving
Issued 17 September 1997 Resolved
During field sobriety test Helmsman admitted to consuming alcohol on watch in violation of 33 CFR 95.045. Breathalizer test administered under 33 CFR95.035 indicated a BAC of .00.
Condition: Unknown
Due 19 September 1997
Resolved 1 October 1997
Lifesaving
Issued 17 September 1997 Resolved
During field sobriety test Helmsman admitted to consuming alcohol on watch in violation of 33 C.F.R. 95.035. Breathalizer test administered under 33 CFR 95.035. Test indicated a BAC of .00.
Condition: Unknown
Due 19 September 1997
Resolved 1 October 1997
Lifesaving
Issued 17 September 1997 Resolved
Master of vessel had alcohol on his breath which led to a breathalizer testunder 33 CFR 95.035. Test indicated a BAC of .05 which is in violation of above law. Confirmatory testing at N.Y. State police barracks revealed BAC of .03. Master was seen consuming alcoholic beverages on duty.
Condition: Unknown
Due 2 February 1998
Resolved 2 February 1998
Fire Fighting
Issued 19 April 1997 Resolved
Emergency fire pump has exhaust leak.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 19 April 1997 Resolved
chart 14826 not currently corrected._x001C_
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 19 April 1997 Resolved
Chart 14839 not currently corrected.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 19 April 1997 Resolved
Chart 14839 not currently corrected._x001C_
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 19 April 1997 Resolved
Chart 14848 not currently corrected.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Fire Fighting
Issued 15 October 1996 Resolved
FIRE HOSES NEED REPLACED DUE TO LEAKS AND SPLITS IN 9 OF 22 FIRE HOSES ONBOARD. SOLAS 74, CH.II-2, PART A, REG.5(f).
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Fire Fighting
Issued 15 October 1996 Resolved
FIRE EXTINGUISHERS WERE NOT INSPECTED FOR THEIR ANNUAL INSPECTION DUE TO BEING AT SEA WHEN INSPECTION CAME DUE. SOLAS 74, CH.II-2, PART A, REG.7(e)
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Fire Fighting
Issued 10 October 1996 Resolved
Solas II-2, Reg. 21: The T-handled access key, to the number 11 fire station, was wasted which prevented easy access to the fire hose loacted inside. The fire station is located on the port side of the vessel.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Lifesaving
Issued 10 October 1996 Resolved
Solas III-19: Portside liferaft embarkation ladder, missing thimble and screw pin shackle. Rope ladder was tied directly to the pad eye.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Construction/Loadline
Issued 10 December 1994 Resolved
MAKE PERMANENT REPAIRS TO CRACK IN WAY OF NO. 3 DOUBLE BOTTOM STBD TANK BELOW NO. 4 CARGO HOLD BETWEEN FRAMES 117 AND 118._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Fire Fighting
Issued 20 June 1994 Resolved
EMERGENCY FIRE PUMP DIESEL PRIME MOVER STALLED ON START UP DUE TO WATER (CONDENSATION) IN FUEL FILTER, LINES AND LOCAL TANK. CORRECTED IMMEDIATELY.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Navigation
Issued 19 August 1991 Resolved
VESSEL MISSING CURRENT EDITIONS OF CHARTS 14962,14966,14967.
Condition: Unknown
Due 20 August 1991
Resolved 21 August 1991
Navigation
Issued 16 April 1990 Resolved
U.S. LIGHT LIST OUTDATED (1986) NO FORIEGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 16 April 1990 Resolved
CHARTS 14768, 14865, 14963, AND 14968 MISSING NO FORIEGN EQUIVALENT ONBOARD
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 16 April 1990 Resolved
CHARTS 14802, 14848, 14850, 14860, 14883 OUTDATED NO FORIEGN EQUIVALENT ONBOARD.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Navigation
Issued 2 April 1988 Resolved
U.S.COAST PILOT NO.5 1985 EDITION HAD NO CORRECTIONS. NO FOREIGN EQUIVALENTONBOARD.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Documentation
Issued 2 April 1988 Resolved
OIL TRANSFER PROCEDURES WERE NOT COMPLETE.
Condition: Unknown
Due 2 April 1988
Resolved 2 April 1988
Navigation
Issued 29 March 1988 Resolved
NO BLOCK DIAGRAM FOR STEERING CHANGE OVER PROCEDURES POSTED ON THE BRIDGE.WRITTEN INSTRUCTIONS ONLY WERE POSTED.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Navigation
Issued 29 March 1988 Resolved
OUTDATED TIDAL CURRENT TABLES, OUTDATED FOREIGN EQUIVALENT.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Navigation
Issued 29 March 1988 Resolved
OUTDATED TIDE TABLES, OUTDATED FOREIGN EQUIVALENT.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Navigation
Issued 29 March 1988 Resolved
MARINE CHART #11370 NOT CURRENT EDITION OF NOR CURRENTLY CORRECTED. NO FOREIGN EQUIVALENT AVAILABLE ON BOARD.
Condition: Unknown
Due 29 March 1988
Resolved 29 March 1988
Navigation
Issued 15 July 1985 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Accommodation/Occupational Safety
Issued 12 July 1984 Resolved
40 CFR 140.3(D) THE EFFLUENT SHALL NOT HAVE A FECAL COLIFORM BACTERIAL COUNT OF GREATER THAN 200 PER 100 MILLILITERS NOR SUSPENDED SOLIDS GREATER THAN 150 MG/L IN A TYPE II MSD SYSTEM.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.