MAURY USCG vessel records Sign in
← All vessels

NORSEA

NORSEA is a 1977 tank ship. The Coast Guard has recorded 40 inspections since 1985, most recently in March 2006, along with 19 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 1985 to 2006. Most recent: inspection, 13 March 2006.

Built
1977
Last inspected
13 March 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7416870 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225129
Flag
NORWAY
—
Maury page id
psix-225129

Inspections, by type

…with no type recorded29
Years with a record 16 calendar years (1985–2006)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12900 - Convention (Subpart B), Net Ton
33401 - Dead Weight, Ton
19351 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

13 March 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2601260
7 March 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2598064
6 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2351473
30 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323449
20 January 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277777
6 November 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2235881
17 June 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1821479
7 February 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 90988
3 January 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 285724
3 January 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1056989
30 January 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412484
10 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407773
19 August 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 406980
1 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406451
7 January 1997 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 206792
7 January 1997 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 767339
1 January 1997 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 398859
21 March 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 389013
21 March 1996 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079696
16 March 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 651997
24 January 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 536046
24 January 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257205
9 January 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 348036
7 January 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 500337
28 June 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 450533
4 December 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 340668
4 December 1990 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1235216
9 February 1989 Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1345397
8 February 1989 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 328350
31 January 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 328204
2 September 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 446185
23 September 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320987
29 August 1987 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1005508
17 June 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 504363
25 February 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 451250
18 November 1986 Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020101
11 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290972
10 April 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 509223
4 October 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 304839
3 July 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 302954

Deficiency record · 19

Fire Fighting › Fire Pumps › Arrangement
Issued 6 November 2004 Resolved
Emergency fire pump exhaust leaking, repair as original to satisfaction of class surveyor. SOLAS 74(A) II-2/54.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 20 January 2005
Resolution: Inspected and cleared by class on December 16, 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 6 November 2004 Resolved
Hydraulic piping located at port manifold has soft patches. Repair as original to satifaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 20 January 2005
Resolution: Inspected and cleared by class on December 16, 2004
Engineering › Generator (propulsion-electric) › Wiring
Issued 6 November 2004 Resolved
Emergency Generator Oil Temp, Oil Pressure, and cooling water temp guages do not work, repair as original to satisfaction of class surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 20 January 2005
Resolution: Inspected and cleared by class on December 16, 2004
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 November 2004 Resolved
Leaks in cooling water piping on the #2 and 3 SSDG. Leaks to be repaired to the satisfaction of class. SOLAS 74(A) III/26.3
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 December 2004
Resolved 20 January 2005
Resolution: Inspected and cleared by class on December 16, 2004
Electrical › Electrical Distribution System (emergency)
Issued 17 June 2003 Resolved
Provide Class approval for emergency battery wiring for GMDSS. Wiring was installed running through battery room ventilation duct. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 June 2003
Resolved 18 June 2003
Resolution: DNV SURVEYOR APPROVED WIRING.
Fire Fighting › Fixed Deck Foam System
Issued 17 June 2003 Resolved
Make permanent repairs to the main deck foam fire fighting line IWO midship, below port cargo discharge piping, and under the stbd aft monitor. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2003
Resolved 18 June 2003
Resolution: Permanent repairs completed satisfactorily.
Fire Fighting › Fire Hydrants
Issued 17 June 2003 Resolved
Make permanent repairs to the two fire hydrants on stern "A" deck to allow for proper fire fighting pressure. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2003
Resolved 18 June 2003
Resolution: Permanent repairs completed satisfactorily.
Fire Fighting › Miscellaneous Items
Issued 17 June 2003 Resolved
Make permanent repairs to the piping for the two forward most foam monitors. LEGACY COMPONENT DESC: Foam Monitors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2003
Resolved 18 June 2003
Resolution: Permanent repairs completed satisfactorily.
Fire Fighting › Emergency Fire Pumps
Issued 17 June 2003 Resolved
Prove proper operation of emergency fire pump to the attending Class surveyor. Emergency pump would not start without the introduction of large quantities of starting agent. LEGACY COMPONENT DESC: Starting Pump
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2003
Resolved 18 June 2003
Resolution: DNV SURVEYOR APPROVED OPERATION OF EMERGENCY PUMP.
Engineering › Compressed Air System (control)
Issued 17 June 2003 Resolved
Prove proper operation to the satisfaction of attending Coast guard Inspector of the cargo pump emergency stop IWO port side midship. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2003
Resolved 18 June 2003
Resolution: Emergency stop operational.
Deck/Cargo
Issued 1 August 1997 Resolved
PROVIDE PROPER EMERGENCY LIGHTERING EQUIPMENT IN ACCORDANCE WITH 33 CFR 157.410.
Condition: Unknown
Due 10 September 1997
Resolved 10 September 1997
Navigation
Issued 1 August 1997 Resolved
PROVIDE PROPER AUTOPILOT ALARM ARRANGEMENT IN ACCORDANCE WITH 33 CFR 157.440.
Condition: Unknown
Due 10 September 1997
Resolved 10 September 1997
Navigation
Issued 31 January 1989 Resolved
VESSEL'S 1988 EDITION BRITISH ADMIRALTY COAST PILOT ON BOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Navigation
Issued 31 January 1989 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH IT'S SECONDARY RADAR NON OPERATIO-NAL.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Navigation
Issued 31 January 1989 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT CHART 12327 ON BOARD. VESSEL PREVIOUSLY CITED FOR SAME DISCREPANCY ON 20 SEPTEMBER 1988.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Navigation
Issued 31 January 1989 Resolved
VESSEL'S BRITISH ADMIRALTY CHART 2755 ON BOARD NOT CIORRECTED UP TO DATE THROUGH THE ;LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 9 January 1992
Resolved 9 January 1992
Fire Fighting
Issued 3 July 1985 Resolved
VESSEL DID NOT HAVE ONBOARD A SHIPS EMERGENCY PLAN LOCATED IN WEATHER TIGHTCONTAINER AVAILABLE FOR SHORESIDE FIREFIGHTING PERSONNEL AS REQUIRED BY SOLAS CHAPTER II-2 REG 20-2 AMENDED 1981.
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Fire Fighting
Issued 3 July 1985 Resolved
VESSEL DID NOT HAVE ONBOARD A FIXED CO2 OR WATER SPRAY SYSTEM IN THE PAINT LOCKER AS REQUIRED BY 46 CFR 34.05-5(3).
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985
Navigation
Issued 3 July 1985 Resolved
VESSEL DID NOT HAVE ONBOARD LOCAL CHART 11343 FOR AREA OF TRANSIT AS REQUIRED BY 33 CFR 164.33(A)(1).
Condition: Unknown
Due 3 July 1985
Resolved 3 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.