MAURY USCG vessel records Sign in
← All vessels

NORBREEZE

NORBREEZE is a 1977 tank ship. The Coast Guard has recorded 34 inspections since 1986, most recently in February 2006, along with 71 deficiencies — 15 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 1986 to 2006. Most recent: operational control imposed, 16 February 2006.

Built
1977
Last inspected
14 February 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7416882 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225130
Flag
PANAMA
—
Maury page id
psix-225130

Inspections, by type

…with no type recorded19
Years with a record 12 calendar years (1986–2006)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11191 - Regulatory (Subpart C or D), Net Ton
33401 - Dead Weight, Ton
19351 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

14 February 2006 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2582561
14 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2427305
27 December 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2265194
23 December 2004 Deficiency Check · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2263949
9 January 2004 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1980115
8 May 2003 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788572
13 January 2003 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1727748
5 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 411651
5 January 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 785379
7 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 721845
6 February 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 400321
2 February 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 399725
2 February 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1103169
6 October 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 530467
6 October 1991 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1246977
16 November 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 340423
16 November 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1226713
5 May 1990 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 462754
25 January 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904098
18 January 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 924011
23 October 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1203687
7 October 1989 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1028212
6 October 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 515322
1 September 1989 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1198340
9 June 1989 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 536756
7 November 1988 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 891409
4 November 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 326655
12 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 483185
11 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029606
2 February 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327588
22 August 1987 Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1339389
16 January 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 313794
18 November 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 513511
4 February 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 307537

Deficiency record · 71

Construction/Loadline › Markings › Load Line Mark
Issued 14 February 2006 No resolution recorded
Loadlines not marked in contrasting color and permanently fixed to the hull. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 February 2006 No resolution recorded
Name of vessel not plainly visible on bow. Fix prior to the next U.S. port after sailing foreign to the satisfaction of U.S. Coast Guard Inspector.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 14 February 2006 Resolved
Emergency escape breathing device not in working condition.
Condition: Unknown
Due 14 February 2006
Resolved 14 February 2006
Resolution: Replaced air bottle.
Electrical › Electric Generation Source (service) › Panelboard
Issued 14 February 2006 Resolved
Nonconductive matting throughout engine room in front of electrical panels missing.
Condition: Improper/Lack of Maintenance
Due 14 February 2006
Resolved 14 February 2006
Resolution: Mats are now in place.
Engineering › Steam System (main) › Lagging/Insulation
Issued 14 February 2006 No resolution recorded
Insulation on steam lines and exhaust throughout engine room missing. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Door
Issued 14 February 2006 No resolution recorded
Door on upper deck of engine room leading to accommodations has wasted/ missing hinges. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Electrical › Electric Generation Source (service) › Panelboard
Issued 14 February 2006 No resolution recorded
Gauges and sight glasses on electrical feed panel in engine control room, control panel in engine control room, panel 22, panel 46, panel 57, panel 43, panel 10 and turning gear box on the 3rd deck of engine room are cracked, missing or broken. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Main › Condition
Issued 14 February 2006 No resolution recorded
Pin hole leaks on the #2 and #3 fire monitors on the main deck. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Action required: 705 - Other - as specified
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 14 February 2006 No resolution recorded
Cement patches used in place of scuppers. Fix prior to the next U.S. port after sailing foreign to the satisfaction of U.S. Coast Guard Inspector. 33CFR155.310(a)(3)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › End Bulkhead
Issued 14 February 2006 No resolution recorded
Railing on catwalk in engine room upper deck missing. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign. ICLL66-2/25.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Ventilation › General
Issued 14 February 2006 No resolution recorded
Fan inlet on upper deck of engine room missing grading. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Deck Plating
Issued 14 February 2006 No resolution recorded
Deck plating on steps under both manifolds wasted. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2006 No resolution recorded
Electrical piping on main deck wasted. Fix to the satisfaction of class prior to the next U.S. port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Feedwater/Condensate Water System › Tank
Issued 14 February 2006 No resolution recorded
Calorifier Tank wasted/leaking. Fix to the satisfaction of attending class surveyer prior to next U.S. port of call.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 February 2006 No resolution recorded
Excessive leakage of #4 generators coolant jacket water. Fix to the satisfaction of an attending class surveyor prior to next U.S. port of call after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 February 2006 No resolution recorded
Excessive leakage of #2 and #3 generators lube oil. Fix to the satisfaction of class surveyor prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 February 2006 No resolution recorded
Vessel was issued a Letter of Deviation 09FEB06 to enter the port of Corpus Christi and again to depart on 15FEB06 without a properly operating primary radar. This is based on the understanding the equipment will be operational prior to next U.S. port after sailing foriegn.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 January 2004 Resolved
S/W LINE FOR GENERATOR COOLER ENDCAP WASTED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 23 December 2004
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE PROPER REPAIRS.
Lifesaving › Lifeboat
Issued 13 January 2003 Resolved
Port side lifeboat davit not maintained as per vessels maintenance manual. SOLAS 74 amended CH III Reg 20/Reg 36. Class (RINA) survey report to verify proper operation and maintenance of both lifeboat davits.
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 8 May 2003
Resolution: Rcv''d fax from vsl''s agent. Class Report from RINA ( 09Feb03) Stated Port and Stbd Lifeboats found maintained, pulleys, sheaves, and cables greased. Both lifeboats lowered to embarkation deck. Ship''s record found updated in good order.
Navigation
Issued 6 February 1997 Resolved
CURRENTLY CORRECT U.S. CHART 18645 AND 18649 PRIOR TO DEPARTURE FROM ANCHORAGE AND TRANSIT TO STOCKTON.
Condition: Unknown
Due 10 February 1997
Resolved 11 March 1997
Construction/Loadline
Issued 6 February 1997 Resolved
HAVE CLASS INSPECT CEMENT BOX PATCH OVER GRAYWATER SKIN VALVE AND MAKE RECOMENDATIONS FOR REPAIRS.
Condition: Unknown
Due 21 February 1997
Resolved 11 March 1997
Construction/Loadline
Issued 2 February 1997 Resolved
FOREPEAK BALLAST TANK HAS 12" DIAMETER HOLE ON STARBOARD SIDE BETWEEN HAWSEPIPE AND FRAME 108 WHERE ANCHOR TRIPPING PALM HAS POUNDED INTO HULL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Electrical
Issued 2 February 1997 Resolved
EMERGENCY GENERATOR COOLING FAN IS NOT GUARDED TO PROTECT PERSONNEL.
Condition: Unknown
Due 2 February 1997
Resolved 11 February 1997
Documentation
Issued 2 February 1997 Resolved
VESSEL RESPONSE PLAN DOES NOT HAVE A GEOGRAPHIC-SPECIFIC ANNEX.
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Lifesaving
Issued 2 February 1997 Resolved
MISSING 5 OF 12 PARACHUTE FLARES._x001C_ _x001C_ -SOLAS_x001C_ _x001C_
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Construction/Loadline
Issued 2 February 1997 Resolved
RAISED WATERTIGHT HATCH ON AFT POOP DECK HAS 4 DOGS WHICH ARE SIEZED OR BROKEN. -ILLC 66 ANNEX I/12
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Construction/Loadline
Issued 2 February 1997 Resolved
RAISED WT HATCH ON PORT POOP DECK HAS 6 DOGS WHICH ARE SIEZED. -ILCC 66 ANNEX I/12
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Engineering
Issued 2 February 1997 Resolved
FLAME SCREENS ARE NOT PROVIDED, OR NEED REPAIR, AT THE FOLLOWING VENT LOCATIONS: PAINT ROOM PORT VENT; STBD F/O WING TANK; AFT F/W FILL; FOC'SLE F/O DEEP TANK; PORT & STBD FOC'SLE ABAFT STORE ROOM VENTS; STBD CARGO DECK BY ULLAGE OPENING 11C._x001C_
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
GALLEY SINK DRAIN IS CLOGGED AND LEAKING ONTO DECK. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
SEVERAL GALLEY VENT HOOD SCREENS HAVE EXCESSIVE ACCUMULATION OF DIRT AND GREASE. -ILO 147_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Electrical
Issued 2 February 1997 Resolved
BARE ELECTRICAL CABLES ARE EXPOSED OVER HOSPITAL SPACE TOP BUNK WHERE LIGHTING FIXTURE WAS REMOVED. -ILO 147; 60 SOLAS II/27(a)
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
THERMAL INSULATION IN OVERHEAD OF CO2 ROOM (FIRE BOUNDARY) HAS BEEN REMOVEDIN WAY OF PIPE PENETRATIONS; INTEGRITY NEEDS TO BE RESTORED TO SATISFACTIONOF CLASS SOCIETY. -60 SOLAS II/36
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Lifesaving
Issued 2 February 1997 Resolved
WATER SPRAY SYSTEM FOR STBD LIFE BOAT DOES NOT PROVIDE PROPER COVERAGE._x001C_ -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Deck/Cargo
Issued 2 February 1997 Resolved
EMERGENCY CARGO PUMP SHUTDOWNS AT P/S CARGO MANIFOLDS ARE NOT LABELLED. _x001C_ -MARPOL 73/78, 33 CFR 155
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Lifesaving
Issued 2 February 1997 Resolved
STARBOARD LIFEBOAT DAVIT DOES NOT LOWER BOAT FREELY. -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FIRE FIGHTING PROCEDURES MUST REFLECT BETTER CREW COMMUNICATION AND TEAM COORDINATION. -74 SOLAS (AMENDED) XI-4
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
GALLEY RICE DISPENSER DOES NOT HAVE COVER. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FOG APPLICATORS BEHIND PIPE RACK ARE NOT READILY AVAILABLE FOR EMERGENCY USE; ONE IS MISSING A NOZZLE. -74 SOLAS (AMENDED) II-2/32
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
SPRINKLER NOZZLE IN PAINT LOCKER IS CLOGGED WITH CORROSION. -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
HANDRAILS ARE NOT PROVIDED ON LOWER STEPS LEADING TO MACHINE SHOP. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Navigation
Issued 2 February 1997 Resolved
BOLTED LINKAGES FOR STEERING GEAR DO NOT HAVE SECURING DEVICES SUCH AS LOCKING PINS, DOUBLE NUTS, OF "NYLOCK" NUTS.
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FIRE STATION IN LOWER ENGINE ROOM IS INOPERABLE DUE TO CORRODED/SIEZED CAP ON FIRE PLUG. -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Engineering
Issued 2 February 1997 Resolved
SPILL CONTAINMENT COAMINGS ON CARGO DECK HAVE LEAKING COVER PLATES. _x001C_ -MARPOL 73/78 ANNEX I/9; 33 CFR 155.310
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FIREMAIN PIPING HAS LEAKS LOCATED FORWARD OF FORWARD-MOST FOAM MONITOR AND AT FOC'SLE FIREPLUG. - 60 SOLAS II/56/(e)
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
OPERATOR PLATFORM AT FORWARD FIRE MONITOR IS MISSING PLANKS. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
FORWARD CARGO DECK CATWALK IS DAMAGED AND UNSAFE. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Construction/Loadline
Issued 2 February 1997 Resolved
HINGED VENT COVER IS MISSING ON STBE FOC'SLE DECK. -ILLC 66 ANNEX I/19
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
LADDER HANDRAIL LEADING TO STBE FOC'SLE IS BROKEN. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FIREFIGHTING GEAR LOCKER IN FOC'SLE HAS BROKEN AND INOPERABLE LATCH. -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Fire Fighting
Issued 2 February 1997 Resolved
FIREMAN'S BREATHING APPARATUS IN FOC'SLE LOCKER HAS BROKEN AIR HOSE. -SOLAS
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 2 February 1997 Resolved
RAIL ON STBD SIDE NEAR TANK 3S HAS 3 BROKEN COURSE SECTIONS. -ILO 147
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Lifesaving
Issued 2 February 1997 Resolved
EMERGENCY SHOWER AND EMERGENCY EYEWASH ON STBD SIDE ARE INOPERABLE. -ILO 147; 33 CFR SUBCHAPTER "O"
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Construction/Loadline
Issued 2 February 1997 Resolved
STBD BULKHEAD OF CARGO PUMP ROOM HAS HOLE IN VICINITY OF EYEWASH STATION. _x001C_-ILLC 66 ANNEX I/18
Condition: Unknown
Due 2 February 1997
Resolved 5 February 1997
Accommodation/Occupational Safety
Issued 16 November 1990 Resolved
Marpol V Vessel dumped plastics more than 3 nautical miles from shore, a sea a violation of Marpol Annex V
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Deck/Cargo
Issued 16 November 1990 Resolved
flame screens distorted in order to fit over ullage openings, improper fit.ullage to be supervised while open by pic._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Deck/Cargo
Issued 16 November 1990 Resolved
SUBMIT CERTIFICATE OF FITNESS TO G-MSC-3 400 SEVENTH STREET S.W. WASHINGTOND.C. 20590 TO UPDATE CARGOES AND RESTRICTIONS LIST PRIOR TO CARRIAGE OF COMPLIANCE CARGOES.
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Navigation
Issued 7 October 1989 Resolved
VESSEL'S STEERING SYSTEM NOT IN COMPLIANCE WITH SOLAS CHAPTER II 1 PART C REGULATION 29.
Condition: Unknown
Due 7 October 1989
Resolved 7 October 1989
Deck/Cargo
Issued 7 October 1989 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY 150% HYDRO STATIC TEST OF CARGO PIPING SYSTEM.
Condition: Unknown
Due 7 October 1989
Resolved 7 October 1989
Deck/Cargo
Issued 7 October 1989 Resolved
LIP ON CARGO TANK ULAGE OPENS WASTED FLAME SCREENS DO NOT FIT PROPERLY. FLAME SCREENS WASTED. REPAIR ULAGE LIPS AND FLAME SCREENS TO PROVIDE SATISFACTORY FIT. NOT TO BE LEFT UNATTENDED UNTIL REPAIRED.
Condition: Unknown
Due 7 October 1989
Resolved 7 October 1989
Deck/Cargo
Issued 7 October 1989 Resolved
NUMBER THREE CARGO PUMP LEAKING, MAKE PERMANENT REPAIR TO CARGO PUMP AND PROVE PROPER OPERATION OF CARGO PUMP.
Condition: Unknown
Due 7 October 1989
Resolved 7 October 1989
Navigation
Issued 4 November 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Navigation
Issued 4 November 1988 Resolved
33 CFR 164.33(A)(1)(II) THE MARINE CHARTS ON BOARD THE VESSEL USED TO TRANSIT THE AREA (BOSTON INNER HARBOR) WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Documentation
Issued 2 February 1988 Resolved
PRIOR TO TRANSFERRING COMPLIANCE CARGOS IN UNITED STATES WATERS RENEW THE SUBCHAPTER "O" ENDORSEMENT.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Deck/Cargo
Issued 22 August 1987 Resolved
REPAIR CARGO MONITOR. ALL CARGO RESIDUE AND BALLAST WATER IS TO BE RETAINED ON BOARD OR DISCHARGED TO A RECEPTION FACILITY UNTIL CARGO MONITORIS REPAIRED.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Deck/Cargo
Issued 22 August 1987 Resolved
REPLACE ALL 20X20 MESH FLAME SCREENS IN THE CARGO DOME ULLAGE OPENINGS WITH30X30 MESH FLAME SCREENS BY NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Fire Fighting
Issued 22 August 1987 Resolved
RENEW BROKEN FIREMAIN HYDRANT VALVE HAND WHEEL ON PORT SIDE IMMEDIATELY FORWARD OF THE #2 FOAM MONITOR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Deck/Cargo
Issued 22 August 1987 Resolved
PROVIDE PERMANENTLY INSTALLED EMERGENCY EYEWASH STATION IN CARGO AREA AND MARK AS REQUIRED BY 46 CFR 153.216 BY NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Deck/Cargo
Issued 22 August 1987 Resolved
MARK EMERGENCY SHOWER STATIONS WITH THE WORDS "EMERGENCY SHOWER" AS REQUIRED BY 46 CFR 153.216(C)(4) BY NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Documentation
Issued 22 August 1987 Resolved
PROVIDE ON BOARD CURRENT EDITIONS OF 46 CFR PARTS 1-40 AND 146-155, AND 33 CFR PARTS 1-199 PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Accommodation/Occupational Safety
Issued 22 August 1987 Resolved
RENEW WASTED LADDER RUNGS ON THE AFT LADDER TO THE CATWALK OVER THE STARBOARD MANIFOLD AT NEXT DRYDOCK.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987
Deck/Cargo
Issued 22 August 1987 Resolved
PROVIDE TWO SAFETY EQUIPMENT LOCKERS AS SPECIFIED BY 46 CFR 153.215 FOR STOWAGE OF THE EQUIPMENT SPECIFIED IN 153.214 BY NEXT U.S. PORT.
Condition: Unknown
Due 22 August 1987
Resolved 22 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.