MAURY USCG vessel records Sign in
← All vessels

AGIOS LOUKAS

AGIOS LOUKAS is a 1977 freight ship. The Coast Guard has recorded 58 inspections since 1985, most recently in December 2008, along with 45 deficiencies and 16 operational controls.

Records from 1985 to 2008. Most recent: operational control imposed, 29 December 2008.

Built
1977
Last inspected
29 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7420259 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225155
Flag
TURKEY
—
Maury page id
psix-225155

Inspections, by type

…with no type recorded36
Years with a record 15 calendar years (1985–2008)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13552 - Convention (Subpart B), Net Ton
37528 - Dead Weight, Ton
45579 - Displacement, Ton
20986 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PAKRAC Freight Ship · MISLE 225745 · 17 June 2002 · activity 1637388LBT 26 Tank Barge · MISLE 49522 · 4 June 1996 · activity 146724CREOLE 7 Industrial Vessel · MISLE 50805 · 4 June 1996 · activity 146724CREOLE RIVERS Towing Vessel · MISLE 156804 · 4 June 1996 · activity 146724

Inspection history · 58

29 December 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3386150
29 December 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3386664
18 November 2008 PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3359921
30 May 2008 MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3215337
5 March 2008 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3154811
28 January 2008 ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3132312
1 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3123289
1 January 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3123319
30 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3122618
30 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3127329
27 December 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3121518
19 December 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3118250
19 November 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3101075
15 July 2007 MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2985953
3 January 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2849743
19 October 2006 MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2803370
11 September 2006 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2771819
7 May 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2642881
17 April 2006 PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2625793
3 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2560169
8 August 2005 MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2451316
29 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2444650
3 February 2005 MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2285366
3 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2268404
3 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2307326
1 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2267611
13 August 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2165519
24 July 2004 NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2143223
23 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2143158
23 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2146947
21 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2140706
19 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2138769
5 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065313
17 February 2004 Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2007787
17 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1989094
29 May 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1804865
12 November 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1704523
27 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1681588
16 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1676455
17 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1637388
17 June 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1653934
28 May 2002 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1621946
16 April 2002 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1605418
18 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287143
7 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 285753
9 April 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 277018
19 January 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 273818
13 January 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 181528
24 November 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 397819
5 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 391948
4 June 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 146724
21 April 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 445928
3 December 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 528332
23 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 319733
5 January 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 313580
18 September 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 471927
4 November 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305460
25 April 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301625

Deficiency record · 45

Navigation › Collision/Grounding Avoidance › Radar
Issued 29 December 2008 Resolved
Vessel was granted a deviation from the rules allowing operation in the Sector New Orleans COTP zone with an inoperative radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2008
Resolved 2 January 2009
Resolution: Received a technician''s report from Electro-Tech, Inc. stating that the radar was repaired, tested, and found to be working properly.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 17 January 2008 Resolved
The No. 3 generator has a fuel line which is leaking, do not operate generator until fuel line is repaired.
Action required: 705 - Other - as specified
Due 4 February 2008
Resolved 30 January 2008
Resolution: Received class report from PRS satisfying requirement.
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 17 January 2008 Resolved
The No. 1 generator's jacket water cooling pump is leaking.
Action required: 705 - Other - as specified
Due 4 February 2008
Resolved 30 January 2008
Resolution: Received class report from PRS satisfying requirement.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 17 January 2008 Resolved
The portside accommodation ladder cannot be lowered and can only be raised manually.
Action required: 705 - Other - as specified
Due 4 February 2008
Resolved 30 January 2008
Resolution: Received class report from PRS satisfying requirement.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 January 2008 Resolved
While anchored, barge came alongside to begin discharge operations. Crane barge struck stbd side hull, stbd side bridge wing affecting navigational lights, bridge deck, and associated hand railing. Both navigational lights remain operational but not as required.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2008
Resolved 1 January 2008
Resolution: Received Polski Rejestr Statkow class report stating bridge wing bulwarks and deck plating, navigation deck railing and scuppers, and navigation lights were all repaired and in good working order.
Construction/Loadline › Hull › Bottom Plating
Issued 31 December 2007 Resolved
While attempting to get u/w from Pilottown Anchorage, pilot and Captain determined vessel had grounded.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 December 2007
Resolved 1 January 2008
Resolution: Received Panama Maritime Flag State report stating had been freed from grounding and found no ingress of water into ballast tanks.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 April 2006 Resolved
The 15ppm automatic shut-off device for the Oily Water Separator is not operating as designed. Do not use Oily Water Separator while in U.S. waters. Repair automatic shut-off device to operate as designed to the satisfaction of the attending classification society.
Action required: 705 - Other - as specified
Due 24 April 2006
Resolved 7 May 2006
Resolution: Received class report from DNV satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 April 2006 Resolved
The Marine Sanitation Device has a corroded back plate that is separating from the MSD tank. Repair back plate to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 7 May 2006
Resolution: Received class report from DNV satisfying the requirement.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 3 February 2005 Resolved
The emergency generator primary stored energy source (battery) has been depleted. The emergency generator was unable to be started using its secondary energy source (manual).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 February 2005
Resolution: Vessel received two new batteries while Coast Guard on board and demonstrated proper operation of the primary means of start.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 29 May 2003 Resolved
Number 3 generator overspeed trip had a noteworthy oil leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 30 May 2003
Resolution: Received proper documentation clearing deficiency.
Lifesaving › Lifeboat
Issued 16 April 2002 Resolved
Both lifeboats have developed minor fractures in the fiberglss covering the seats/floatation chambers. Make permanent repairs or arrange with class a time table to make repairs prior to 28May02. SOLAS 60 III/5(b). LEGACY COMPONENT DESC: Seating
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Resolution: CLEARED BY FAX
Fire Fighting
Issued 7 January 2001 Resolved
AUTOMATIC CLOSING DEVICE ON ENGINE ROOM ACCESS DOOR (POOP DECK) INOPERATIVE.
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Fire Fighting
Issued 7 January 2001 Resolved
PIPE PENATRATION IN AFT ENGINE ROOM A-60 BULKHEAD OPEN AND NOT RESISTANT TOFIRE AS PER SOLAS 60 II/38(a)
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Lifesaving
Issued 7 January 2001 Resolved
EXPOSED ROTATING EQUIPMENT ON EMERGENCY FIRE PUMP NOT FITTED WITH PROTECTIVE GUARD.
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Navigation
Issued 7 January 2001 Resolved
RUDDER ANGLE INDICATORS ON BRIDGE DEVIATED 5 DEGREES FROM ACTUAL RUDDER POSITION AS INDICATED IN STEERING GEAR ROOM.
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Accommodation/Occupational Safety
Issued 19 January 2000 Resolved
The compressors for cold storage are missing guards for the moving parts in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Fire Fighting
Issued 19 January 2000 Resolved
The emergency fire pump is inoperable in violation of SOLAS 74 (ammended)CH. II-2 Reg. 21
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Fire Fighting
Issued 19 January 2000 Resolved
The fire main was holed in violation of SOLAS 74 (amended) CH. II-2 Reg. 21
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Accommodation/Occupational Safety
Issued 19 January 2000 Resolved
There was excessive oil on deck next to generators presenting a fire and safety hazard in violation of SOLAS 74 (amended) CH. I Reg. 11
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Engineering
Issued 19 January 2000 Resolved
The oily water separator piping, foam holding tank, and seawater outlet_x001C_ piping all were holed and improperly repaired in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Unknown
Issued 19 January 2000 Resolved
The fresh water pump motor controler and drainage piping was leaking in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
There were numerous dead ended electricial wires in various spaces on the ship in violation of SOLAS 60 CH. II Reg. 27.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Construction/Loadline
Issued 19 January 2000 Resolved
The transverse bulkhead was leaking water from a hole located at the top seam near the port side generator deck in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Construction/Loadline
Issued 19 January 2000 Resolved
The ballast valves for the port and starboard ballast tanks were missing in violation of SOLAS 74 (amended) CH. I Reg. 11
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Construction/Loadline
Issued 19 January 2000 Resolved
The bolts for the #3 port and starboard ballast tank vents were missing inviolation of SOLAS 74 (amended) CH. I reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Engineering
Issued 19 January 2000 Resolved
The fuel oil and diesel oil separators were leaking in violation of SOLAS 74 (amended) CH. I reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
The #3 generator was broken apart and not operational in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
The seawater cooling pumps for the diesel generators were not operational in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Construction/Loadline
Issued 19 January 2000 Resolved
The bilge valve wheels on the fresh water after peak tank and bidge suction piping were missing valve wheels in violation of SOLAS 74 (amended)CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
Remote starter for emergency generator in foam room was broken in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Unknown
Issued 19 January 2000 Resolved
The fresh water system evaparator piping was not properly repaired in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
The generators (all three) have leaking fuel pumps in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Electrical
Issued 19 January 2000 Resolved
The #1 and #2 generators are leaking cooling water in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Fire Fighting
Issued 19 January 2000 Resolved
Both SCBA's on board are not serviceable in violation of SOLAS 74 (amended) CH. II-2 Reg. 21.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Fire Fighting
Issued 19 January 2000 Resolved
The paint locker CO2 System is not properly rigged and serviced in violation of SOLAS 74 (amended) CH. II-2 Reg. 21.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Engineering
Issued 19 January 2000 Resolved
The main engine is leaking cooling water from the starboard side at the #1and #2 cylinders in violation of SOLAS 74 (amended) CH. I Reg. 11.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Documentation
Issued 19 January 2000 Resolved
The documentaion for the machinery repairs was not properly logged in accordance with ISM requirements in violation of SOLAS 74 (amended) CH. IX.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Fire Fighting
Issued 19 January 2000 Resolved
11 portable fire extinguishers out of the 38 on board were condemed by theservice company in violation of SOLAS 74 (amended) CH. II-2 Reg. 21.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Unknown
Issued 19 January 2000 Resolved
The ISM system for the vessel has not been properly implemented in violation of SOLAS 74 (amended) CH. IX.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Navigation
Issued 19 January 2000 Resolved
The echo depth sounder is only working intermittently in violation of 33 C.F.R. 164.35.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Lifesaving
Issued 5 June 1996 Resolved
MAKE PROPER AND PERMANENT REPAIRS TO BOTH LIFE BOAT DAVIT LIMIT SWITCHES, CURRENTLY THE STBD SIDE WILL NOT SHUT OFF POWER TO THE WINCH, AND THE PORT SIDE IS VERY STIFF AND HARD TO MOVE. _x001C_ SOLAS 60 REG. 36 K
Condition: Unknown
Due 10 June 1996
Resolved 14 June 1996
Construction/Loadline
Issued 5 June 1996 Resolved
MAKE PROPER AND PERMANENT REPAIRS TO THE VESSEL'S HULL ON THE STBD SIDE BOWA 2 FT BY 1 TO 1.5 INCH GASH CAUSED BY A COLLISION AT THE 13.7M DRAFT MARK.TO BE VERIFIED BY CLASS PRIOR TO DEPARTURE PORT OF NOLA.
Condition: Unknown
Due 10 June 1996
Resolved 14 June 1996
Navigation
Issued 25 April 1985 Resolved
VESSES FAILED TO MAINTAIN CURRENT COAST PILOT PUBLICATION ONBOARD.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985
Navigation
Issued 25 April 1985 Resolved
VESSEL FAILED TO MAINTAIN CURRENT LIGHT LIST PUBLICATION ONBOARD.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985
Navigation
Issued 25 April 1985 Resolved
VESSEL FAILED TO MAINTAIN CURRENT TIDAL CURRENT TABLE PUBLICATION ONBOARD.
Condition: Unknown
Due 25 April 1985
Resolved 25 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.