MAURY USCG vessel records Sign in
← All vessels

JOIDES RESOLUTION

JOIDES RESOLUTION is a 1978 research vessel. The Coast Guard has recorded 26 inspections since 1983, most recently in November 2019, along with 40 deficiencies.

Records from 1983 to 2019. Most recent: inspection, 20 November 2019.

Built
1978
Last inspected
20 November 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7423081 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225178
Flag
CYPRUS
—
Maury page id
psix-225178

Inspections, by type

…with no type recorded17
Years with a record 18 calendar years (1983–2019)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3084 - Convention (Subpart B), Net Ton
9586 - Dead Weight, Net Ton
14421 - Displacement, Net Ton
10282 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

20 November 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6859145
10 October 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6832491
16 September 2019 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6809279
12 December 2016 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6056043
8 December 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6039312
27 February 2012 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4251999
6 February 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3414276
28 May 2005 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2370596
19 June 2004 MTSA/ISPS Verification · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2100843
1 February 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1725684
25 October 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 294856
9 September 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 281892
23 May 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 278129
11 August 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 406725
23 July 1997 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 405828
17 October 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 396519
19 February 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 388069
18 March 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 349553
28 February 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 342181
9 August 1990 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 338747
30 March 1990 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 335537
22 November 1989 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 333817
16 February 1989 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 328545
12 April 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 301316
8 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975023
20 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277162

Deficiency record · 40

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2019 Resolved
SOLAS 60, CH 11, REG 58(b) Piping for fire smothering gas shall be arranged to provide effective distribution of the gas. Co2 pipes were observed bearing loads that could compromise the ability to distribute gas. 0725
Action required: 10 - Deficiency Rectified
Resolved 16 September 2019
Resolution: Crew removed loads from piping for fire smothering gas.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 September 2019 Resolved
1 LLC, ANNEX 1, REG 8 40 AC THE ADMINISTRATION SHALL SATISFY ITSELF THAT THE GENERAL STRUCTUAL STRENGTH OF THE HULL IS SUFFICIENT. OBSERVED 02 FRACTURES BY CHOCKS, FORWARD ON PORT SIDE. 0930
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2019
Resolved 20 November 2019
Resolution: Fractures chocks on the port side have been repaired and welded.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2019 Resolved
ILLC, ANNEX 1, REG 8 LOAD LINE MARKINGS SHALL BE PAINTED IN A COLOR TO CONTRAST WITH THEIR BACKGROUND. LOAD LINE MARKING OBSERVED PAINTED THE SAME COLOR AS THE BACKGROUND. 1220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 10 October 2019
Resolution: Load Line markings have been painted.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 16 September 2019 Resolved
SOLAS 60, CH 1, REG 10 SURVEYS SHALL ENSURE THAT ALL ARRANGMENTS, MATERIALS, BOILERS, MAIN AND AUX MACHINERY ARE IN ALL RESPECTS SATISFACTORY FOR THE INTENDED SERVICE. OBSERVED EXCESSIVE OIL ACCUMULATION BENEATH MACHINERY IN ENGINE ROOM, INDICATING UNSATISFACTORY CONDITION. 0750
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2019
Resolution: Received pictures of the engine room indicating the excess oil accumulation under the machinery had been removed.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 8 December 2016 Resolved
Def 1) 2555 – Documentation – The company and ship shall comply with the requirements of the ISM Code. The Document of Compliance should be issued by the administration for a duration not to exceed five years. ISM DOC does not have an expiration date nor does it have a completion date of the audit on which the certificate is based. 74SOLAS14 IV Reg 3.1 / ISM Code(2000) Reg 13.2
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2016
Resolved 12 December 2016
Resolution: Vessel provided a new ISM - Document of Compliace from their classification society that complies with ISM Code.
Fire Fighting
Issued 25 October 2001 Resolved
Provide proof of servicing for the fixed CO2 firefighting system IAW SOLAS 74 Amended, Chapter I, Regulation 8(b)(iii).
Condition: Unknown
Due 19 January 2002
Resolved 19 January 2002
Resolution: Received proof of servicing for the fixed CO2 system.
Documentation
Issued 9 September 2000 Resolved
Update Fire Control Plan to include fire boundary (including doors) information. SOLAS 74 AM II-2/20
Condition: Unknown
Due 7 November 2000
Resolved 7 November 2000
Fire Fighting
Issued 23 May 2000 Resolved
Fire Control Plan does not have proper IMO symbology. SOLAS 74 amended II-2/20 and resolution A.654(16).
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Fire Fighting
Issued 23 May 2000 Resolved
Fire screen doors in stair towers need self-closing devices and hold-back devices must be removed. SOLAS 60 II/42(a)(iii).
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Documentation
Issued 23 May 2000 Resolved
IOPP Certificate has erroneous information. Should state auto stopping device vice manual for the OWS. MARPOL Annex I reg 5.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Construction/Loadline
Issued 23 May 2000 Resolved
Weathertight doors to mud room and sack room have worn or loose weather stripping. ICLL 1966 reg 17(b).
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Lifesaving
Issued 23 July 1997 Resolved
EXPIRED FOOD AND WATER ON LIFEBOATS. SOLAS74.
Condition: Unknown
Due 11 August 1997
Resolved 11 August 1997
Engineering
Issued 19 February 1996 Resolved
OWS AUTOMATIC STOPPING DEVICE WAS NOT OPERATING PROPERLY. PROVIDE COPY OF SURVEYORS ROPERT TO MSO SAN JUAN ATTESTING TO THE PERMINATE REPAIRS TO OWS PRIOR TO NEXT US PORT.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Deck/Cargo
Issued 30 March 1990 Resolved
VESSEL DID NOT HAVE EXPLOSIVES PROPERLY LABELED OR MARKED AS REQUIRED BY 49 CFR 172.300.
Condition: Unknown
Due 9 August 1990
Resolved 30 March 1990
Deck/Cargo
Issued 30 March 1990 Resolved
EACH PACKAGE OF EXPLOSIVES MUST BE SECURED, BRACED, AND DUNNAGED TO PREVENTMOVEMENT IN ANY DIRECTION AS REQUIRED BY 49 CFR 176.130
Condition: Unknown
Due 9 August 1990
Resolved 30 March 1990
Deck/Cargo
Issued 30 March 1990 Resolved
EACH VENTILATOR'S WEATHERDECK OPENING MUST BE COVERED WITH A 30X30 OR FINERWIRE SCREEN IF IT LEADS INTO A MAGAZINE AS REQUIRED BY 49 CFR 176.144
Condition: Unknown
Due 9 August 1990
Resolved 30 March 1990
Documentation
Issued 16 February 1989 Resolved
VESSEL DID NOT HAVE A CERTIFICATE OF FINANCIAL RESPONSIBILITY AS REQUIRED BY 33 CFR 130.3.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Navigation
Issued 16 February 1989 Resolved
VESSEL DID NOT PREFORM AND LOG THE PRE-ARRIVAL TEST PRIOR TO ENTERING PORT AS REQUIRED BY 33 CFR 164.25.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Documentation
Issued 16 February 1989 Resolved
VESSEL DID NOT HAVE A POLLUTION PLACARD POSTED AS REQUIRED BY 33 CFR 155.450. CORRECTED ON THE SPOT.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Documentation
Issued 16 February 1989 Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN A LINE DIAGRAM OF THE PIPING SYSTEM AS REQUIRED BY 33 CFR 155.750 (A)(2)(I).
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Documentation
Issued 16 February 1989 Resolved
VESSEL HAD FAILED TO LOG IN THE OIL RECORD BOOK EACH TIME BILGES WERE PUMPED AS REQUIRED BY 33 CFR 151.25 (D)3, AND 4.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Documentation
Issued 16 February 1989 Resolved
PERSON IN CHARGE OF OPERATION AND MASTER HAD NOT SIGNED OIL RECORD BOOK ENTRIES AS REQUIRED BY 33 CFR 151.25(H).
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Engineering
Issued 16 February 1989 Resolved
VESSEL'S OILY WATER SEPARATOR WAS NOT WORKING AS REQUIRED BY 33 CFR 151.09 (A)(6).
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Engineering
Issued 16 February 1989 Resolved
VESSEL DID NOT HAVE A STANDARD DISCHARGE CONNECTION AS REQUIRED BY 33 CFR 155.430.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Deck/Cargo
Issued 16 February 1989 Resolved
VESSEL HAD RADIOACTIVE MATERIAL AND EXPLOSIVES AS PART OF SHIPS STORES THATWERE NOT CERTIFIED AS REQUIRED BY 46 CFR 147.01-4(2) AND 147.01-7.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Navigation
Issued 16 February 1989 Resolved
EMERGENCY STEERING ROOM RUDDER ANGLE INICATOR DOES NOT SHOW CORRECT RUDDER ANGLE AS REQUIRED BY SOLAS REG.#19.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Navigation
Issued 16 February 1989 Resolved
VESSEL'S STEERING GEAR POWER FAILURE ALARM DID NOT WORK AS REQUIRED BY SOLAS REG.#19.
Condition: Unknown
Due 22 November 1989
Resolved 16 February 1989
Unknown
Issued 8 May 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU SEDCO/BP 471 VIN:LN6151
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Lifesaving
Issued 8 May 1984 Resolved
REPAIR OR REPLACE ALL WATER COMPARTMENTS AS NECESSARY IN ALL MOTOR LIFE BOATS.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Construction/Loadline
Issued 8 May 1984 Resolved
FREE UP AND MAKE WATERTIGHT ALL WATERTIGHT DOORS ON THE MAIN DECK AS NECESSARY.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Construction/Loadline
Issued 8 May 1984 Resolved
REPAIR POWER WATERTIGHT DOOR TO MUD PITS FOR PROPER OPERATION IN A HAZARDOUS AREA.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Unknown
Issued 8 May 1984 Resolved
PROVIDE APPROVED STABILITY LETTER, OPERATING MANUAL, LIFESAVING, FIRE CONTROL, AND HAZARDOUS LOCATION PLANS ON BOARD THE SHIP.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Construction/Loadline
Issued 8 May 1984 Resolved
REPAIR THE QUICK ACTING WATERTIGHT DOOR TO THE CONTROL ROOM.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Lifesaving
Issued 8 May 1984 Resolved
LAUNCH AND OPERATE #2 AND #4 MOTOR LIFEBOATS IN THE WATER.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Lifesaving
Issued 8 May 1984 Resolved
CONDUCT TEST OF THE LINE THROWING GUN.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Electrical
Issued 8 May 1984 Resolved
REPAIR OR REPLACE GENERAL ALARM BELLS ON THE HELIPORT AND THE POOP DECK.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Electrical
Issued 20 April 1983 Resolved
IN MUD PIT AREA PROVIDE EYS SEALS ON GERMAN JUNCTION BOX ON AFT BULKHEAD, FORWARD COMPARTMENT CENTERLINE PRIOR TO 1 APR83.
Condition: Unknown
Due 20 April 1983
Resolved 20 April 1983
Documentation
Issued 20 April 1983 Resolved
PROVIDE STABILITY LETTER AND ACCEPTED OPERATIONS MANUAL ON BOARD PRIOR TO 1 AUG 83
Condition: Unknown
Due 20 April 1983
Resolved 20 April 1983
Unknown
Issued 20 April 1983 Resolved
PROVIDE AN ASME APPROVED RELIEF VALVE SET AT 150 PSIG OR LOWER FOR TAUT LINE TENSIONER AIR RECEIVER PRIOR TO 01APR 83.
Condition: Unknown
Due 20 April 1983
Resolved 20 April 1983
Unknown
Issued 20 April 1983 Resolved
MAKE DRILL FLOOR AIR RECIEVER AVAILABLE FOR INTERNATIONAL EXAM AND TESTING OF RELIEF VALVE AT THE NEXT RIG MOVE.
Condition: Unknown
Due 20 April 1983
Resolved 20 April 1983

Ownership record