MAURY USCG vessel records
← All vessels

CSL LAURENTIEN

CSL LAURENTIEN is a 1977 freight ship. The Coast Guard has recorded 43 inspections since 2016, most recently in July 2026, along with 9 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 12 July 2026.

Built
1977
Last inspected
12 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7423108
225180
Flag
CANADA
Maury page id
psix-225180

Documentation record

Tonnage as PSIX records it16338 - Regulatory (Subpart C or D), Net Ton
24024 - Convention (Subpart B), Gross Ton
33084 - Dead Weight, Ton
22674 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 43

12 July 2026 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8435988
4 May 2026 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8361362
19 April 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8352085
19 April 2026 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8353969
6 April 2026 PSC B · Administrative Inspection · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8340455
26 March 2026 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8332493
3 November 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8262320
26 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8218260
15 August 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8210655
11 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8207157
31 July 2025 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8199110
21 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8190847
11 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8110269
19 August 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7985172
20 May 2024 Canadian Vsl Safety Exam (D9 only) · PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7916054
28 November 2023 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7830117
6 August 2023 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7761483
10 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7685154
8 May 2023 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7683512
8 May 2023 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7683722
23 March 2023 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7655673
25 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7599546
25 October 2022 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7583546
26 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7566300
27 August 2022 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7544269
6 August 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7526106
6 August 2022 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7537142
31 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7422866
3 December 2021 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7361934
1 December 2021 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7360277
12 April 2021 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7173434
10 October 2020 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7075906
22 July 2020 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7013178
15 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6939610
21 March 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6930389
30 December 2019 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6881012
14 October 2019 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6834119
22 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6758090
1 May 2019 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6674632
12 October 2018 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6559327
14 April 2018 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6391413
6 October 2017 Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6282075
23 September 2016 Canadian Vsl Safety Exam (D9 only) · ISPS II Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6005723

Deficiency record · 9

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 July 2026 Resolved
Minimum requirements for vessel automated vital systems - General requirements for all vital systems automation. Vessel's Oil Mist detector on starboard main engine activated causing engine shutdown. Unclear reason as to why alarm, vessel to troubleshoot for cause with class rectification approval in Sarnia.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 July 2026
Resolved 13 July 2026
Resolution: Technician troubleshot issue and discovered defective oil mist detector measuring head. Replaced and fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 April 2026 Resolved
The Material design,construction, workmanship,and arrangement of main propulsion machinery and of each auxiliary directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS marine vessel rules. No pitch response from the stick on the bridge or engine control room and intermittent CPP alarms. Vessel shall be assisted by at least 01 harbor assist tug during transit into Duluth Harbor, including all maneuvering and mooring operations. 46 CFR 58.05-1(a) 15ac
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2026
Resolution: Class issued report stating malfunction was due to card failure. Card was replaced by crew and everything works now. See documents tab for more details.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 April 2026 Resolved
The Material design,construction, workmanship,and arrangement of main propulsion machinery and of each auxiliary directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS marine vessel rules. No pitch response from the stick on the bridge or engine control room and intermittent CPP alarms. 46 CFR 58.05-1(a) 10C
Action required: 10 - Deficiency Rectified
Due 6 April 2026
Resolved 6 April 2026
Resolution: Vessel made necessary repairs. Class report attached in Documents.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 August 2024 Resolved
In special cases a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements. Affect repairs to the crack in the starboard number 1 ballast tank. 46 CFR 92.01-10(a) / ac / 40
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 August 2024
Resolution: Received LR Survey report and St. [name withheld] inspection report. Corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 October 2022 Resolved
Vessel's hull is cracked near #1 port ballast tank
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2022
Resolved 26 October 2022
Resolution: Permanent repairs were made to the satisfaction of the RO
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 27 August 2022 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Vessel's load line has been scratched and worn and does not have contrasting colors. ICLL 66 (05 ED.) CH 1 / Regulation 8 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2022
Resolved 26 September 2022
Resolution: Senior vessel manager submitted picture proof that painting of load line and draft marks was conducted according to ICLL.
14 - Pollution Prevention › 147 - Anti-Fouling › Paint condition
Issued 27 August 2022 Resolved
Remove fouling organisms from the vessel's hull, piping and tanks on a regular basis. Vessel's hull has excessive growth below waterline and near discharge outlets. 33CFR151.2050 (f) 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2022
Resolved 26 September 2022
Resolution: Senior Vessel manager attested to hull being cleaned at last drydocking and that the growth is removed during the winter months on the lakes.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 December 2019 Resolved
A survey shall be made every time a defect is discovered which affects the safety of the vessel, two cracks were found in the hull in the portside ballast tank which caused water ingress. Effect permanent repairs to portside #5 ballast tank hull plating fracture in vicinity of frames 39 and 40. 46 CFR 91.30-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 March 2020
Resolution: corrected - via class report
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 May 2019 Resolved
Vessel grounded in St. Marys River, condition of hull is unknown. Conduct hull survey and provide documentation to the local OCMI from flag state or class stating condition of the hull and structural members; if needed, conduct appropriate repairs prior to returning to a US port, after sailing foreign.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 May 2019
Resolved 2 May 2019
Resolution: [name withheld] stating a satisfactory visual inspection of affected compartments and that a bottom visual examination will be completed next dry dock

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.