Records from 1984 to 1998. Most recent: inspection, 23 July 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
23 July 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418845
17 February 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 412860
13 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400612
20 March 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 710377
14 March 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 376132
23 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340831
30 July 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 310498
15 August 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 297516
Navigation
Issued 23 July 1998
Resolved
GYRO COMPASS REPEATERS NOT OPERATING PROPERLY._x001C_ _x001C_ 33 CFR 164.35(d)_x001C_
Condition: Unknown
Due 25 July 1998
Resolved 3 August 1998
Lifesaving
Issued 17 February 1998
Resolved
CORRECT PRIOR TO DEPARTURE THIS PORT LIFEBOAT PROVISIONS NOT SUITABLE FOR CONSUMPTION.
Condition: Unknown
Due 24 February 1998
Resolved 19 February 1998
Fire Fighting
Issued 17 February 1998
Resolved
PRIOR TO NEXT U.S. VOYAGE PROVIDE CLASS ATTESTATION TO INSTALLED FIXED FIREFIGHTING SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 17 March 1998
Resolved 19 February 1998
Fire Fighting
Issued 17 February 1998
Resolved
CORRECT PRIOR TO DEPARTURE THIS PORT HOLE IN FIRE MAIN BY FOREPEAK HYDRANT.
Condition: Unknown
Due 24 February 1998
Resolved 19 February 1998
Fire Fighting
Issued 17 February 1998
Resolved
OBTAIN CLASS ATTESTATION AS TO PERMANENT REPAIRS TO FIRE MAIN BY WAY OF FOREPEAK HYDRANT.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Navigation
Issued 17 February 1998
Resolved
PRIOR TO NEXT U.S. VOYAGE MAKE REPAIRS TO RESERVE LUBE OIL SIGHT GUAGE IN STEERING COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Electrical
Issued 17 February 1998
Resolved
CORRECT PRIOR TO DEPARTURE THIS PORT INSTALL BLANKS OR SWITCHES IN OPEN SLOTS ON ELECTRICAL CONTROL PANEL IN ENGINE CONTROL ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1998
Resolved 19 February 1998
Lifesaving
Issued 17 February 1998
Resolved
CORRECT PRIOR TO DEPARTURE THIS PORT INSTALL GUARDS ON 3 OF 4 COMPRESSORS IN COMPRESSOR ROOM.
Condition: Unknown
Due 24 February 1998
Resolved 19 February 1998
Fire Fighting
Issued 17 February 1998
Resolved
PRIOR TO NEXT U.S. VOYAGE MAKE REPAIRS TO #1 FIRE PUMP PRESSURE GUAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Navigation
Issued 14 March 1995
Resolved
The vessel was missing a copy of the Tidal Current tables or it's foreignequivalent.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Navigation
Issued 30 July 1986
Resolved
VESSEL'S LORAN-C WAS INOPERATIVE.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Navigation
Issued 30 July 1986
Resolved
VESSEL FAILED TO HAVE CURRENTLY CORRECTED CHARTS OF THE AREA TO BE TRANSIT-ED.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Navigation
Issued 30 July 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997