MAURY USCG vessel records Sign in
← All vessels

IBN QUTAIBAH

IBN QUTAIBAH is a 1976 freight ship. The Coast Guard has recorded 12 inspections since 1987, most recently in August 2000, along with 7 deficiencies and 2 operational controls.

Records from 1987 to 2000. Most recent: operational control imposed, 17 August 2000.

Built
1976
Last inspected
17 August 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7428964 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225221
Flag
SAUDI ARABIA
—
Maury page id
psix-225221

Inspections, by type

…with no type recorded12
Years with a record 8 calendar years (1987–2000)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8816 - Convention (Subpart B), Net Ton
23618 - Dead Weight, Ton
15455 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 12

17 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281214
8 April 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 480929
1 April 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426927
27 October 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 421754
23 April 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 414852
14 April 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 414757
21 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400680
16 May 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391247
16 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 368614
9 March 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 454466
1 March 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 349077
28 May 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 316366

Deficiency record · 7

Lifesaving
Issued 17 August 2000 Resolved
INADEQUATE PROVISIONS FOR LIFEBOATS ON BOARD. MUST PROVIDE ENOUGH PROVISIONS FOR LIFEBOATS FOR 45 PERSONS EACH SIDE NO LATER THAN 17SEP00. (SOLAS 74/III REG 8.2 A.S.)
Condition: Unknown
Due 17 September 2000
Resolved 22 August 2000
Engineering
Issued 17 August 2000 Resolved
LEAKS IN FUEL DISTRIBUTION PIPING TO #3 GENERATOR. REPAIR FUEL LEAKS IN FUEL LINE TO SATISFACTION OF FLAG STATE OR REP NO LATER THAN 17SEP00.
Condition: Unknown
Due 25 February 2001
Resolved 25 February 2001
Fire Fighting
Issued 17 August 2000 Resolved
FIRE MAIN LINE AND VALVES IN ENGINE ROOM LEAKING. REPAIR LEAKS IN FIREMAINLINE AND SHAFT PACKING ON FIRE PUMPS AND VALVES FOR FIRE MAIN IN ENGINE ROOM TO THE SATISFACTION OF CERTIFICATE ISSUING AUTHORITY, BUT NO LATER THAN 17SEP00. (SOLAS 74 AMMENDED/II-2 REGULATION 21 A.S.)
Condition: Unknown
Due 25 February 2001
Resolved 25 February 2001
Lifesaving
Issued 14 April 1998 Resolved
Temporary, wooden structure built on the aft poopdeck not of proper design or construction. No fire suppression capabilities. Solas 60/Reg 45, Solas74
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Lifesaving
Issued 14 April 1998 Resolved
Several light covers missing throughout ship (eng rm, galley, & crews living areas) ILO 147/PWSA 33 USC 1223(b)
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Lifesaving
Issued 16 May 1996 Resolved
LIFERAFT EXPIRED AND IS DUE FOR SERVICING.
Condition: Unknown
Due 21 February 1997
Resolved 21 February 1997
Navigation
Issued 16 July 1994 Resolved
provide the vessel with a copy of the current U.S. Coast Pilot for the areato be transitted.
Condition: Unknown
Due 23 May 1996
Resolved 23 May 1996

Ownership record