MAURY USCG vessel records Sign in
← All vessels

DON CONSTANTINO

DON CONSTANTINO is a 1976 freight ship. The Coast Guard has recorded 21 inspections since 1985, most recently in January 2001, along with 27 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 21 January 2001.

Built
1976
Last inspected
21 January 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7430668 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225242
Flag
GREECE
—
Maury page id
psix-225242

Inspections, by type

…with no type recorded21
Years with a record 12 calendar years (1985–2001)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27789 - Convention (Subpart B), Net Ton
25500 - Regulatory (Subpart C or D), Net Ton
63159 - Dead Weight, Ton
31803 - Convention (Subpart B), Gross Ton
33200 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

21 January 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286300
25 September 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282536
19 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282324
19 September 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282336
25 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413565
18 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 146988
14 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424779
5 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 647039
19 March 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377005
28 October 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 539410
20 December 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 347985
16 May 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 524248
6 August 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 338587
12 May 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 438672
26 July 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 331667
24 January 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 320753
8 July 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 317148
30 January 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 487875
21 October 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 304846
1 July 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 302972
9 January 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 299769

Deficiency record · 27

Electrical
Issued 19 September 2000 Resolved
WIRE END NOT PROPERLY TERMINATED ON #2 STEERING PUMP BARE WARE EXPOSED AND NOT CONNECTED 220 VOLTS
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Navigation
Issued 19 September 2000 Resolved
AMP METER BROKEN AND NOT WORKING
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Navigation
Issued 19 September 2000 Resolved
STEERING ELECTRICAL CONTROL BOX BLOCKED OFF BY SCRAP METAL RACK INSTALLED BY CREW
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Navigation
Issued 19 September 2000 Resolved
STEERING GEAR HAS MULTIPLE HYDRQULIC LEAKS FROM BLOKS PIPES PUMPS AND MAIN RAM SEALS.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Fire Fighting
Issued 19 September 2000 Resolved
FIRE PLUG FOR STEERING FIRE STATION NOT ACCESABLE 18' UP OFF DECK WITH NO LADDER. STEERING IS IN COMMON SPACE WITH ENGINE ROOM
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 19 September 2000 Resolved
SEA WATER SUPPLY TO OWS HAS SOFT PATCH NOT LEAKING.
Condition: Unknown
Due 19 October 2000
Resolved 25 September 2000
Lifesaving
Issued 19 September 2000 Resolved
EXCESSIVE FUEL IN PURIFER ROOM BILGE
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Engineering
Issued 19 September 2000 Resolved
#2 GENERATOR HAS MAJOR F/O LEAKS ON ALL CYLINDERS
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Engineering
Issued 19 September 2000 Resolved
#2 GENERATOR HAS MAJOR WATER LEAK FROM #5 CYLINDER AND A SOFT PATCH ON JACKET WATER COOLER LINE THAT IS LEAKING.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Engineering
Issued 19 September 2000 Resolved
#3 GENERATOR HAS MAJOR FUEL LEAKS FROM ALL CYLINDERS AND FUEL PUMPS.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Engineering
Issued 19 September 2000 Resolved
#3 GENERATOR LEAKING JACKET WATER FROM ALL CYLINDER HEADS.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Engineering
Issued 19 September 2000 Resolved
#1 GENERATOR HAS MAJOR FUEL LEAKS FROM ALL CYLINDERS AND FUEL INJECTORS.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Electrical
Issued 19 September 2000 Resolved
EMERGENDY GENERATOR DID NOT START FOR INSPECTION.
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 19 September 2000 Resolved
SEWAGE TANK HAS BONDO PATCHES AND IS LEAKING ON BACK SIDE. SYSTEM IS NOT WORKING
Condition: Unknown
Due 19 September 2000
Resolved 25 September 2000
Accommodation/Occupational Safety
Issued 25 February 1998 Resolved
ENGINE ROOM EMERGENCY ESCAPE TRUNK DOOR DOEWS NOT CLOSE COMPLETELY_x001C_ _x001C_ _x001C_ SOLAS 60 REG II/38_x001C_
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Accommodation/Occupational Safety
Issued 25 February 1998 Resolved
MSD NOT PROPERLY LABELED_x001C_ _x001C_ _x001C_ 33 CFR 159.59
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Engineering
Issued 25 February 1998 Resolved
OIL POLLUTION PLACARD BY OILYWATER SEPARATOR MISSING_x001C_ _x001C_ _x001C_ 33 CFR 155.450_x001C_
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Navigation
Issued 19 March 1995 Resolved
VESSELS PORT STEERING GEAR PUMP WAS LEAKING HYDRAULIC FLUID.
Condition: Unknown
Due 22 March 1995
Resolved 3 May 1995
Navigation
Issued 19 March 1995 Resolved
VESSELS OVER 10,000 GT, SECOND MARINE RADAR WAS NOT OPERATING.
Condition: Unknown
Due 22 March 1995
Resolved 3 May 1995
Navigation
Issued 19 March 1995 Resolved
VESSELS MARINE CHART FOR THE AREA TO BE TRANSITED (11370) WAS NOT CURRENTLYCORRECT.
Condition: Unknown
Due 22 March 1995
Resolved 3 May 1995
Lifesaving
Issued 19 March 1995 Resolved
FLAMMABLE LIQUIDS STORED IN IMPROPER LOCATION.
Condition: Unknown
Due 19 April 1995
Resolved 10 May 1995
Electrical
Issued 19 March 1995 Resolved
VESSEL MISSING PROTECTIVE LIGHT COVERS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Navigation
Issued 8 July 1987 Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. COAST PILOT,VOL.3,OR ITS FOREIGN EQUIV,WHICH WAS REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPENTO MORRISVILLE,PA.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Documentation
Issued 8 July 1987 Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQ BY 33CFR155.720 AND FURTHER DISCRIBED BY REF TO 33CFR154.310 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN PROCEDURES FOR TOPPING OFF TANKS,REPORTING OIL DISCHARGES INTO THE WATER,CLOSING AND OPENING VSL OPENINGS,AND # OF PERSONS REQ.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Navigation
Issued 8 July 1987 Resolved
A VIO OF 33CFR164.30 IN THAT U.S. CHARTS 12214,12304,12311,12312,12313,AND 12314 USED BY THE VSL WERE CORRECTED TO NTM 52/86,WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO MORRISVILLE,PA.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Accommodation/Occupational Safety
Issued 1 July 1985 Resolved
NO SMOKING WARNING SIGN WAS NOT POSTED AT GANGWAY AS REQUIRED BY 49CFR176.60
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Fire Fighting
Issued 9 January 1985 Resolved
MISSING DUPLICATE COPY OF FIRE CONTROL PLAN OUTSIDE THE DECK HOUSE SOLAS 74 REG.20.2
Condition: Unknown
Due 9 January 1985
Resolved 9 January 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.