← All vessels
AMAZONA
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named AMAZONA
AMAZONA is a 1977 freight ship. The Coast Guard has recorded 11 inspections since 1984, most recently in January 2000, along with 42 deficiencies and 2 operational controls.
Records from 1984 to 2000. Most recent: inspection, 26 January 2000.
- Built
- 1977
- Last inspected
- 26 January 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7431234 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225246
Flag
GREECE
—
Maury page id
psix-225246
Inspections, by type
…with no type recorded11
Years with a record
9 calendar years (1984–2000)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6409 - Regulatory (Subpart C or D), Net Ton
15665 - Dead Weight, Ton
9814 - Regulatory (Subpart C or D), Gross Ton
15665 - Dead Weight, Ton
9814 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
26 January 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 274107
17 October 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 421642
3 March 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 401102
22 May 1996
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 391018
15 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 677234
9 May 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 390971
9 June 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 367671
2 December 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 362675
19 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343897
18 September 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 311487
1 November 1984
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 298637
Deficiency record · 42
Engineering
Issued 3 March 1997
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Engineering
Issued 3 March 1997
Resolved
REPAIR LEAKING MAIN ENGINE SALTWATER PUMP AND JACKET WATER PUMP.
Lifesaving
Issued 3 March 1997
Resolved
CLEAN EXCESSIVE OIL FROM ENGINE CASING AND AROUND DECK AND GENERATORS.
Engineering
Issued 3 March 1997
Resolved
EMPTY OPEN BUCKETS AND DRUMS OF OIL IN ENGINE ROOM.
Navigation
Issued 3 March 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 3 March 1997
Resolved
DEMOSTRATE PROPER OPERATION OF EMERGENCY FIRE PUMP.
Construction/Loadline
Issued 9 May 1996
Resolved
Renew deteriorated knife edge on battery locker door frame._x001C_ ICLL 66 REG. 18_x001C_ _x001C_ _x001C_
Engineering
Issued 9 May 1996
Resolved
Provide protection guards for all exposed moving parts in the following areas which is not all inclusive. A) A/C blower in engine room control_x001C_ room. B) A/C blower units units in compressor room. C)Where main engine &shaft gear connect lower engine room.
Electrical
Issued 9 May 1996
Resolved
Repair/Renew light fixture in paint locker. Ensure light fixture is of an approved explosion proof type.
Fire Fighting
Issued 9 May 1996
Resolved
Ensure all vent closures move freely. Unseize galley vent closure._x001C_ SOLAS 60 II/47
Fire Fighting
Issued 9 May 1996
Resolved
Stow all paints onboard the vessel in the paint locker._x001C_ SOLAS 74 (Amended) II-2/18
Engineering
Issued 9 May 1996
Resolved
Renew/Repair exhaust pipe and leaking radiator on the emergency fire pump._x001C_SOLAS 74 (Amended) II-2/22
Fire Fighting
Issued 9 May 1996
Resolved
Prove operation of all general fire alarms. The bell in the accommodation space port side was inoperable._x001C_ SOLAS 74 (Amended) II-2/21
Fire Fighting
Issued 9 May 1996
Resolved
Provide onboard an up to date fire control plan._x001C_ SOLAS 74 (Amended) II-2/20
Navigation
Issued 9 May 1996
Resolved
Remove all oil and oily residues from the steering room, cranes, tank tops and containers throughout the vessel.
Construction/Loadline
Issued 9 May 1996
Resolved
Renew/Repair deteriorated aft bulkhead in galley in way of fire box.
Engineering
Issued 9 May 1996
Resolved
Provide suitable means for stopping/shutting off oil fuel suction pipes from storage, setting or daily service tank from a remote location outside the space. (This applies to the engine room remote cutoff valves that werewired in the open position.) SOLAS 60 II/69(c)
Engineering
Issued 9 May 1996
Resolved
Prove operation of the ships oily water separating equipment._x001C_ 33 C.F.R. 155.370 or MARPOL 73/78 Annex 1/16
Engineering
Issued 9 May 1996
Resolved
Remove all rubber hoses on fuel oil lines and make permanent repairs in theengine room etc pipe in way of #17 D/O setting tank.
Electrical
Issued 9 May 1996
Resolved
Install electrical juction boxes were needed to prevent electrical shock topersonnel in the engine room. Provide all electrical outlets on the weather decks w/ covers. All dead ended wires should be removed or properly capped. SOLAS 60 II/27
Lifesaving
Issued 9 May 1996
Resolved
Perform a satisfactory abandon ship drill and fire drill to the satisfaction of the attending U.S. Coast Guard Marine Inspectors.
Lifesaving
Issued 9 May 1996
Resolved
Provide/Renew all lifejackets on board with a light which is within the experation date of the light._x001C_ SOLAS 74 (Amended) III/19.2/27.2
Fire Fighting
Issued 9 May 1996
Resolved
Remove all worn/deform fire hose couplings throughout the vessel. Ensure all hoses and nozzles are in good working condition and readly accessable._x001C_SOLAS 74 (Ameended) II-2/21
Construction/Loadline
Issued 9 May 1996
Resolved
Renew all missing dog bolts to water tight doors, hatches and vent covers throughout the vessel.
Accommodation/Occupational Safety
Issued 9 May 1996
Resolved
Make permanent repairs to sanitary piping on bridge look out deck.
Electrical
Issued 9 May 1996
Resolved
Renew/Repair weather deck light fixture on main deck above co2 room._x001C_ SOLAS 60 II/27
Lifesaving
Issued 9 May 1996
Resolved
Renew all expired medications in ships hospital.
Electrical
Issued 9 May 1996
Resolved
Renew/Repair all non-working emergency light fixtures throughout vessel.
Lifesaving
Issued 9 May 1996
Resolved
Renew deteriorated tricing pendant on the port side aft lifeboat._x001C_ SOLAS 74 (Amended) III/19.2
Fire Fighting
Issued 9 May 1996
Resolved
Renew/Repair seized up anchor wash valves.
Engineering
Issued 9 May 1996
Resolved
Make permanent repairs to deteriorated piping to distilling unit in engine room.
Engineering
Issued 9 May 1996
Resolved
Renew as original deteriorated/holed fresh water generator piping.
Lifesaving
Issued 9 May 1996
Resolved
Ppoperly install quick release lifebuoys on bridge wings._x001C_ SOLAS 60 III/21(g)
Fire Fighting
Issued 9 May 1996
Resolved
Provide on board for review, instructions for maintenance and operations ofall equipment and installations on board for fighting and containment of fire. These instructions shall be kept under one cover._x001C_ SOLAS 74 (Amended) II-2/20
Fire Fighting
Issued 9 May 1996
Resolved
Repair/Renew fire hydrant coupling on starboard side forecastle._x001C_ SOLAS 74 (Amended) II-2/21
Construction/Loadline
Issued 9 May 1996
Resolved
Renew/Repair deteriorated watertight door frame in way of #4 cargo hold port side._x001C_ ICLL 66 Reg 18
Accommodation/Occupational Safety
Issued 2 December 1993
Resolved
MARINE SAFETY DEVICE FOR M/V AMAZONIA WAS NOT LABELED PROPERLY NOR WAS A COAST GUARD APPROVAL LETTER ON BOARD.
Construction/Loadline
Issued 2 December 1993
Resolved
POLLUTION PLACARDS FOR THE M/V AMAZONIA WERE NOT POSTED IN THE ENGINE ROOM AND THE CONTROL ROOM.
Engineering
Issued 19 May 1991
Resolved
INSTALL FLAME SCREENS IN ALL LUBE/DIESEL/FUEL OIL DECK TANK VENTS.
Engineering
Issued 19 May 1991
Resolved
THE 15PPM OILY WATER SEPARATOR AND ALARM IS INOPERABLE.
Navigation
Issued 19 May 1991
Resolved
PROVIDE A BLOCK DIAGRAM OF THE STEERING GEAR FOR THE BRIDGE AND ONE FOR THESTEERING GEAR COMPARTMENT.
Navigation
Issued 19 May 1991
Resolved
PROVIDE A MANEUVERING FACT SHEET FOR THE BRIDGE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.