MAURY USCG vessel records Sign in
← All vessels

SEA ATHINA

SEA ATHINA is a 1978 freight ship. The Coast Guard has recorded 13 inspections since 1986, most recently in June 2002, along with 7 deficiencies.

Records from 1986 to 2002. Most recent: inspection, 7 June 2002.

Built
1978
Last inspected
7 June 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7431246 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225247
Flag
GREECE
—
Maury page id
psix-225247

Inspections, by type

…with no type recorded11
Years with a record 7 calendar years (1986–2002)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it7633 - Regulatory (Subpart C or D), Net Ton
18020 - Dead Weight, Ton
12230 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

7 June 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1627882
13 May 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1614790
22 June 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 60244
22 June 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86131
18 June 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 291057
10 April 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 414698
9 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 414700
13 December 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646812
14 November 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 384863
19 December 1994 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 373484
12 December 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 373217
25 February 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 349014
24 November 1986 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 312849

Deficiency record · 7

Fire Fighting › Emergency Fire Pumps
Issued 13 May 2002 Resolved
Suction and delivery gauges on the emergency fire pump to be replaced. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 7 June 2002
Resolution: Guages were replaced.
Electrical › Lighting (service)
Issued 13 May 2002 Resolved
Repair one explosion proof light in paint locker and provide safety cages for both lights. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 1 June 2002
Resolved 7 June 2002
Resolution: Light globe and cages were replaced.
Navigation › Piloting/Steering
Issued 13 May 2002 Resolved
Failure to have charts and US light list for Great Lakes voyage. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2002
Navigation
Issued 18 June 2001 Resolved
VESSEL DID NOT HAVE THE APPROPRIATE CHART TO NAVIGATE THE SAVANNAH RIVER.
Condition: Unknown
Due 19 June 2001
Resolved 22 June 2001
Navigation
Issued 14 November 1995 Resolved
MISSING CHARTS 1081 AND 1082, BOTH WERE PROVIDED TO THE VESSEL BEFORE DEPARTURE.
Condition: Unknown
Due 14 November 1995
Resolved 14 November 1995
Engineering
Issued 12 December 1994 Resolved
A VIOLATION OF SOLAS IN THAT THE FLAME SCREENS ON THE FUEL OIL AND LUBE OILTANK VENTS WERE WASTED.
Condition: Unknown
Due 19 December 1994
Resolved 19 December 1994
Lifesaving
Issued 12 December 1994 Resolved
A VIOLATION OF SOLAS CHAPTER II-2-6.2 IN THAT THE PORT LIFERAFT DID NOT HAVE A WEAKLINK._x001C_
Condition: Unknown
Due 15 December 1994
Resolved 19 December 1994