← All vessels
WISDOM C
WISDOM C is a 1980 freight ship. The Coast Guard has recorded 18 inspections since 1984, most recently in October 2004, along with 70 deficiencies and 2 operational controls.
Records from 1984 to 2004. Most recent: inspection, 26 October 2004.
- Built
- 1980
- Last inspected
- 26 October 2004
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 70 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7433464 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HPUU
225280
Flag
GREECE
—
Maury page id
psix-225280
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it12534 - Convention (Subpart B), Net Ton
12534 - Regulatory (Subpart C or D), Net Ton
49857 - Displacement, Ton
40274 - Dead Weight, Ton
23381 - Convention (Subpart B), Gross Ton
23381 - Regulatory (Subpart C or D), Gross Ton
12534 - Regulatory (Subpart C or D), Net Ton
49857 - Displacement, Ton
40274 - Dead Weight, Ton
23381 - Convention (Subpart B), Gross Ton
23381 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
26 October 2004
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2228319
20 October 2004
ISPS II Exam · PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2224675
23 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432460
24 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 417238
19 February 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 60393
19 February 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 441619
3 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 61716
24 February 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 400803
26 March 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 389307
28 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383431
21 September 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383124
29 September 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 650028
26 September 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 361223
12 February 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 348788
1 October 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339608
9 September 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 332458
14 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 306325
22 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 297664
Deficiency record · 70
Lifesaving › Launching Appliances › Winch Brake
Issued 20 October 2004
Resolved
Starboard lifeboat break not holding, demonstrate proper operation to the satisfaction of the attending Classification surveyor.
Electrical › Electric Supply System (service) › Cable
Issued 20 October 2004
Resolved
Electrical junction box hanging looses in the engine room bilge, in way of the starboard diesel generator saltwater pump; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 20 October 2004
Resolved
Electrical water level control panel for boiler covered by tin cans; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Engineering › Lubricating Oil Service System › Piping
Issued 20 October 2004
Resolved
Jacket water seawater cooling lines for the lube oil coolers for the generators have soft patches and leaking water; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 20 October 2004
Resolved
Generators #1, #2, and #3 saltwater cooling lines for air coolers are thinned and leaking; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2004
Resolved
Deck plates in engine room are loose and not secured; properly secure all deck plates throughout the engine room to the satisfaction of the attending Classification surveyor.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 October 2004
Resolved
Install guard over the moving machinery parts that are missing; bilge pumps and main engine camshaft; to the satisfaction of the attending Classification surveyor.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 October 2004
Resolved
Reefer cooling water overboard lines have soft patches and leaking; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Construction/Loadline › Structures › Manhole
Issued 20 October 2004
Resolved
Sea chest strainer cover is leaking seawater, starboard side forward engine room; properly secure to the satisfaction of the attending Classification surveyor.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 October 2004
Resolved
Properly install droplight in the bilge by shaft, light is installed using general wiring; to the satisfaction of the attending Classification surveyor.
Engineering › Freshwater Generation System › Piping
Issued 20 October 2004
Resolved
Seawater outlet of the freshwater generator is thinned and leaking; make permanent and proper repairs to the satisfaction of the attending Classification surveyor.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 20 October 2004
Resolved
Many of the cabins that are listed on the fire control plan are being used as storerooms. Classification surveyor is to examine these areas to ensure that they meet the structural fire protection requirements, and the fire control plan is to be updates to show these changes.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 20 October 2004
Resolved
Vessel has many work list items still outstanding from dry dock of September 2004. Vessel is to provide a complete work list to the Cosmoship and then provide to the US Coast Guard Activities New York a copy of this list and Cosmoship's plans and response to this list.
Electrical
Issued 23 August 1999
Resolved
GROUNDING MAT FOR ELECTRIAL PANEL IN ENG. CONTROL ROOM TO SHORT OF LENGTH
Fire Fighting
Issued 23 August 1999
Resolved
FIRE HYDRANTS IN ENGINEERING SPACE LEAKING FROM VALVES
Accommodation/Occupational Safety
Issued 23 August 1999
Resolved
SUPPLY VENTS IN ENGINE ROOM, COVERS MISSING, NEEDS CLEANING OR REPAIRED
Navigation
Issued 23 August 1999
Resolved
RUDDER ANGLE INDICATOR ON PORT BRIDGE WING OFF 4 TO 5 DEG
Lifesaving
Issued 23 August 1999
Resolved
AIR LIFTING MOTOR INOPERTABLE
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 23 August 1999
Resolved
ARPA UNIT NOT WORKING PROPERLY. SHOWING NO VECTORS
Deck/Cargo
Issued 23 August 1999
Resolved
#2 PORT CARGO HATHC PUMP HAS EXCESSIVE HYDRO OIL LEAK
Accommodation/Occupational Safety
Issued 23 August 1999
Resolved
EXCESSIVE OIL, SLIP HAZARD ON ENGINE ROOM LADDERS
Deck/Cargo
Issued 23 August 1999
Resolved
PORT ANCHOR NOT ATTACHED TO CHAIN AND WINDLESS PUMP OUT FOR REPAIR
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 23 August 1999
Resolved
REPAIR AND PROVE PROPER OPERATION OF #2 SSG _x001C_ PROVIDE CLASS REPORT
Electrical
Issued 23 August 1999
Resolved
EXPOSED WIRING IN STEERING ROOM
Fire Fighting
Issued 23 August 1999
Resolved
UNABLE TO CONDUCT PROPER FIRE DRILL
Engineering
Issued 23 August 1999
Resolved
BOILER WATER JACKET HAS PIN HOLE LEAK
Electrical
Issued 23 August 1999
Resolved
# 1 SSG EXHUST SYSTEM NEEDS TO BE REPAIRED/ EXHUSTS TO ENGINE ROOM
Electrical
Issued 23 August 1999
Resolved
IMPROPER GEAR STORED BEHIND ELECTRICAL PANELS
Electrical
Issued 24 June 1998
Resolved
Repair and prove proper operation of the port ship's service generator.
Navigation
Issued 24 June 1998
Resolved
Install rudder angle indicator in After Steering prior to next U.S. port.
Electrical
Issued 24 June 1998
Resolved
Repair excessive fuel and lube oil leaks in way of all three ship's servicegenerators prior to next U.S. port.
Electrical
Issued 24 June 1998
Resolved
Permanently repair holed/cracked raw water line for port ship's service generator prior to next U.S. port.
Fire Fighting
Issued 24 June 1998
Resolved
Remove the non-combination nozzles and provide combination nozzles at all engineering space fire stations prior to next U.S. port.
Construction/Loadline
Issued 24 June 1998
Resolved
Remove excessive fuel and lube oils from bilges in way of generator compartment.
Fire Fighting
Issued 24 June 1998
Resolved
Repair and prove proper operation of the #2 Main Fire Pump.
Fire Fighting
Issued 24 June 1998
Resolved
Repair as required and prove proper operation of the Emergency Fire Pump.
Navigation
Issued 24 June 1998
Resolved
Repair and prove proper operation of the Automatic Radar Plotting Aid (ARPA).
Engineering
Issued 24 February 1997
Resolved
REMOVE OIL, EXCESSIVE, FROM ENGINEERING SPACES BILGES AND FROM ENGINEROOM EQUIPMENT. 33CFR155.470
Lifesaving
Issued 26 March 1996
Resolved
AT NEXT U.S. PORT PROVE SATISFACTORY TEST OF PORT SIDE LIFEBOAT DAVIT PNUEMATIC SYSTEM. UNABLE TO TEST DUE TO VSL MOORED PORTSIDE.
Engineering
Issued 21 September 1995
Resolved
STBD. SIDE CONTAINMENT (BUNKERS) WASTED AND LEAKING FUEL. (33 CFR 155.310)
Navigation
Issued 21 September 1995
Resolved
COMMUNICATION BETWEEN AFT STEERING AND BRIDGE INOPERABLE. (SOLAS CH. II-1 REG. 29.10
Fire Fighting
Issued 21 September 1995
Resolved
FIREMAIN STBD. SIDE FORWARD LEAKING EXCESSIVELY. (SOLAS CH. II-2 REG.4)
Lifesaving
Issued 21 September 1995
Resolved
LIFEJACKETS WASTED/WORN. (SOLAS CH. III REG. 19.2)
Lifesaving
Issued 21 September 1995
Resolved
(2) OF (2) BREATHING APPARATUS ARE NON-FUNCTIONAL (NO-AIR). (SOLAS CH. II-2REG. 17.3)
Engineering
Issued 21 September 1995
Resolved
MAIN ENGINE AIR-START SYSTEM IMPROPER, SYSTEM CAN NOT BE STARTED FROM THE CONTROL ROOM, CAN ONLY BE STARTED IN THE EMERGENCY MODE.
Navigation
Issued 21 September 1995
Resolved
STEERING GEAR PUMP(S) COUULD NOT BE SWITCH-OVER FROM THE BRIDGE. (SOLAS CH.II-1 REG.29.5.2)
Lifesaving
Issued 21 September 1995
Resolved
AIR SYSTEM (FOR RAISING LIFEBOATS) FOR PORT/STBD LIFEBOATS INOPERABLE. (SOLAS CH. III REG.15.2)
Accommodation/Occupational Safety
Issued 21 September 1995
Resolved
SCREENS ABOVE GALLEY STOVE MISSING. (ILO 147)
Engineering
Issued 26 September 1993
Resolved
THE VESSELS CONTAINMENT FOR THE #1 FUEL OIL TANK VENT WAS WASTED. PERMANENT REPAIR REQUIRED PRIOR TO DEPARTURE FROM PORT.
Navigation
Issued 26 September 1993
Resolved
VESSELS EMERGENCY STEERING GEAR WAS INOPERABLE. PERMANENT REPAIR REQUIRED PRIOR TO DEPARTURE FROM PORT.
Fire Fighting
Issued 26 September 1993
Resolved
THE VESSELS PACKING AROUND THE PUMP SHAFT ON THE EMERGENCY FIRE PUMP WAS LEAKING EXCESSIVE AMOUNTS OF WATER. CORRECTION REQUIRED PRIOR TO DEPARTUREFROM PORT.
Documentation
Issued 26 September 1993
Resolved
VESSELS MANNING CERTIFICATE WAS EXPIRED. CORRECTION REQUIRED PRIOR TO DEPARTURE FROM PORT.
Electrical
Issued 26 September 1993
Resolved
VESSEL HAD FAULTY WIRING AND LIGHTING THROUGHOUT THE VESSEL (BARE AND FRAYED WIRES, LIGHT COVERS MISSING). PERMANENT REPAIR REQUIRED PRIOR TO DEPARTURE FROM PORT.
Engineering
Issued 26 September 1993
Resolved
FLAME SCREENS IN THE FUEL OIL TANK VENTS WERE WASTED. PERMANENT REPAIR REQUIRED PRIOR TO DEPARTURE FROM PORT.
Construction/Loadline
Issued 26 September 1993
Resolved
THE VESSELS #5 PORT BALLAST TANK IS CONTAMINATED WITH OIL. THE VESSEL IS PROHIBITED FROM DOING BALLAST OPS INVOLVING THAT TANK AND IT IS REQUIRED TOBE CLEANED PRIOR TO RETURING TO THE U.S.
Engineering
Issued 26 September 1993
Resolved
THE VESSEL HAD EXCESSIVE AMOUNTS OF FUEL OIL IN ITS MAIN TUNNEL. THE LOCATION OF THE LEAK IS UNKNOWN. PERMANENT REPAIR IS REQUIRED PRIOR TO THEVESSELS NEXT U.S. VOYAGE.
Navigation
Issued 26 September 1993
Resolved
THE VESSELS AUTOMATIC RADAR PLOTTING AID REQUIRED BY 33 CFR 164.38(b)(3)(ii) WAS INOPERABLE. DEVIATION WAS GRANTED FOR THE VESSEL TO DEPART PORT. PERMANENT REPAIR REQUIRED PRIOR TO THE NEXT U.S. VOYAGE.
Electrical
Issued 26 September 1993
Resolved
THE VESSELS #3 SHIPS SERVICE GENERATOR WAS DOWN FOR OVERHAUL. PERMANENT REPAIR REQUIRED PRIOR TO NEXT U.S. VOYAGE.
Accommodation/Occupational Safety
Issued 26 September 1993
Resolved
THE VESSELS TYPE II MARINE SANITATION DEVICE WAS NOT CERTIFIED IAW 33 CFR 159.5(a)(1). CERTIFICATION REQUIRED PRIOR TO THE VESSELS NEXT U.S. VOYAGE.
Engineering
Issued 26 September 1993
Resolved
THE VESSELS MAIN ENGINE ROOM READOUTS FOR LUBE OIL PRESSURE, TEMPERATURE, MAIN ENGINE COOLING WATER TEMPERATURE WERE INOPERATIVE. PERMANENT REPAIR REQUIRED PRIOR TO NEXT U.S. VOYAGE.
Documentation
Issued 26 September 1993
Resolved
THE VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL OF THE INFORMATION REQUIRED BY 33 CFR 155.750. CORRECTION REQUIRED PRIOR TO THE VESSELS NEXT U.S. VOYAGE.
Accommodation/Occupational Safety
Issued 26 September 1993
Resolved
THE VESSELS HEATING SYSTEM FOR THE CREW ACCOMADATIONS WAS INOPERABLE. PERMANENT REPAIR REQUIRED PRIOR TO NEXT U.S. VOYAGE.
Documentation
Issued 12 February 1992
Resolved
POLUTION PLACARD NOT PROPERLY POSTED.
Accommodation/Occupational Safety
Issued 12 February 1992
Resolved
VESSEL FAILED TO HAVE CERTIFICATION LABEL AFFIXED TO MSD._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 12 February 1992
Resolved
VESSELS OIL TRANSFER PROCEDURES FAILED TO CONTAIN ALL THE REQUIRED_x001C_ INFORMATION._x001C_ _x001C_ _x001C_
Navigation
Issued 9 September 1989
Resolved
US COAST PILOT NOT CORRECTED TO DATE. A CORRECTED COAST PILOT IS A REQUIREMENT OF 33CFR164.33(A)(2)(I).
Documentation
Issued 9 September 1989
Resolved
THE OIL TRANSFER PROCEDURES REQUIRED BY 33CFR155.750 WERE NOT COMPLETE.
Navigation
Issued 14 January 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED U.S. LIGHT LIST,VOLI, OR ITS EQUIV AS REQ BY 33 CFR 164.33 (A)(2)(II) WAS NOT O/B. THE VSL HAD O/B U.S. LIGHT LIST,VOLI,DTD 1985 WITH NO CORRECTIONS.
Navigation
Issued 14 January 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR EQUIV OF THE AREA TRANSITED AS REQ BY 33 CFR 164.33 (A)(1)(II) WAS NOT O/B. THE VSL HAD O/B U.S. CHARTS #12222 DTD 1985 COR- RECTED TO 36/85,#12253 DTD 1984 WITH NO CORRECTIONS,AND #12221 NOT O/B.
Navigation
Issued 14 January 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED U.S. COAST PILOT,VOL3,OR ITS EQUIV AS REQ BY 33 CFR 164.33 (A)(2)(I) WAS NOT O/B. THE VSL HAD O/BU.S. COAST PILOT,VOL3,DTD 1985 WITH NO CORRECTIONS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.