MAURY USCG vessel records Sign in
← All vessels

EXPLORER S

EXPLORER S is a 1978 freight ship. The Coast Guard has recorded 20 inspections since 1985, most recently in August 2001, along with 34 deficiencies — 4 with no resolution recorded — and 3 operational controls.

Records from 1985 to 2001. Most recent: operational control imposed, 10 August 2001.

Built
1978
Last inspected
10 August 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7433567 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225288
Flag
LIBERIA
—
Maury page id
psix-225288

Inspections, by type

…with no type recorded20
…past their stated due date4
Years with a record 12 calendar years (1985–2001)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13822 - Regulatory (Subpart C or D), Net Ton
380000 - Dead Weight, Ton
77 - Displacement, Ton
22252 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

10 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292434
8 August 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36957
4 October 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 46793
4 October 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 420996
1 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415326
18 October 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 408994
16 April 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 402255
31 January 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 399983
12 January 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 399401
28 September 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 395752
4 June 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 378926
22 April 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 648563
15 April 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 365977
10 March 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 356626
21 February 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 493143
22 July 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 533656
1 October 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 346291
20 September 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 339373
24 March 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 329206
17 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 299779

Deficiency record · 34

Fire Fighting
Issued 10 August 2001 Resolved
#1 and #2 Fire main suction valves are wasted and seeping. Provide class report attesting to the intefrity of #1 and #2 Fire pump suction valves prior to departing port.
Condition: Unknown
Due 11 August 2001
Resolved 13 August 2001
Engineering
Issued 10 August 2001 No resolution recorded
#1 generator jacket water cooling pump seal is leaking. Replace prior to 17Aug 01.
Condition: Unknown
Due 17 August 2001 — due date passed with no resolution recorded
Engineering
Issued 10 August 2001 Resolved
#2 generator oil line to turbo is leaking. Do not operate #2 generator until oil line is repaired to the satisfaction of class.
Condition: Unknown
Due 11 August 2001
Resolved 13 August 2001
Engineering
Issued 10 August 2001 No resolution recorded
#2 cylinder of #2 generator has a rubber drain hose for the injector drain.R eplace with metallic tube prior to 17 Aug 01.
Condition: Unknown
Due 17 August 2001 — due date passed with no resolution recorded
Engineering
Issued 10 August 2001 No resolution recorded
#3 generator jacket water cooling pump seal is leaking. Replace prior to 17 Aug 01.
Condition: Unknown
Due 17 August 2001 — due date passed with no resolution recorded
Engineering
Issued 10 August 2001 No resolution recorded
The main engine exhaust manifold has a leak. Repair to the satisfaction ofclass prior to 17 Aug 01.
Condition: Unknown
Due 17 August 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 4 October 1998 Resolved
BUGS FOUND IN RICE AND DRY STORAGE AREA.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Engineering
Issued 16 April 1997 Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF PROPULTION ENGINE.
Condition: Unknown
Due 16 April 1997
Resolved 17 April 1997
Lifesaving
Issued 31 January 1997 Resolved
Replace lifebuoys on main deck as needed. (unserviceable)
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 31 January 1997 Resolved
Re-place seapainter lines on port and starboard lifeboats. (dry rotted)
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Lifesaving
Issued 31 January 1997 Resolved
Update emergency station bill. (outdated)
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Navigation
Issued 28 September 1996 Resolved
PROVIDE ARPA LABEL PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Fire Fighting
Issued 28 September 1996 Resolved
PRIOR TO NEXT U.S. VISIT UPDATE FIRE CONTROL PLANS.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Accommodation/Occupational Safety
Issued 28 September 1996 Resolved
PRIOR TO RETURNING TO U.S. REPAIR VARIOUS LADDER STEPS LOCATED THROUGHOUT MAIN DECK WHERE WASTED OR WEAK.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO NEXT U.S. VISIT DISPLAY LEGIBLE PLANS OF VESSEL WHERE POSTED IN THE SHIP ACCOMMODATIONS.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Navigation
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE REPAIR STEERING GEAR ROOM COMMUNICATIONS. PROVIDE CLASSREPORT.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE REPLACE HYDROSTATIC RELEASES ON BOTH PORT AND STARBOARD LIFE RAFTS.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO RETURNING TO U.S. REPAIR 2 BROKEN SEATS LOCATED IN STARBOARD LIFE BOAT AND PROVIDE CLASS REPORT OF REPAIRS.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Engineering
Issued 28 September 1996 Resolved
PRIOR TO BUNKERING IN U.S. WATERS PROVIDE BUNKER PIPE TEST TO 1 1/2 TIMES MAX ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Engineering
Issued 28 September 1996 Resolved
PRIOR TO BUNKERING IN U.S. WATERS MAKE PERMANENT REPAIR TO WASTAGE OF THE FUEL TANK CONTAINMENT LOCATED ON THE STBD SIDE OF THE POOP DECK ADJACENT TOAFTER END OF ACCOMMODATION HOUSE AREA. DETERMINE ADEQUACY OF STANDPIPE FOR PATCHED VENT IN SAME CONTAINMENT. PROVIDE CLASS REPORT OF REPAIRS.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Electrical
Issued 28 September 1996 Resolved
PRIOR TO RETURNING TO U.S. REPAIR EXTERIOR ACCOMMODATIONS HOUSE PORT AFT 02DECK LIGHT FIXTURE.
Condition: Unknown
Due 12 January 1997
Resolved 12 January 1997
Construction/Loadline
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT DETERMINING STRUCTURAL ADEQUACY OF AFTER DECK.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Electrical
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT CONFIRMING BATTERIES ARE PROVIDED FOR EMERGENCY GENERATOR AND DEMONSTRATE START UP OF GENERATOR AFTER LOSS OFNORMAL POWER.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Navigation
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE CLASS REPORT DETERMINING REQUIREMENTS OR EXEMPTIONS FOR POWER FAILURE (AUDIBLE) ALARM FOR STEERING MOTOR IN WHEEL HOUSE.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Navigation
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE PROOF OF PROPER OPERATION AND RECEIPT FOR REPAIROF ECHO DEPTH RECORDING DEVICE.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Navigation
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE PROOF OF PROPER RADAR OPERATION AND TECHNICIAN REPORT.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Fire Fighting
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE REPAIR FIRE DOORS IN STAIRTOWER THAT DO NOT CLOSE (1 DOOR HAS NO LATCH OR HANDLE). PROVIDE CLASS REPORT.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PERFORM FIRE AND BOAT DRILL FOR ATTENDING USCG INSPECTOR
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE PROVIDE NEW BATTERIES FOR ALL LIFE PRESERVERS.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Lifesaving
Issued 28 September 1996 Resolved
PRIOR TO DEPARTURE REPLACE MISSING RING BUOY WATERLIGHT.
Condition: Unknown
Due 28 September 1996
Resolved 1 October 1996
Navigation
Issued 4 June 1995 Resolved
THE VESSEL DOES NOT HAVE A CORRECTED BA SAILING DIRECTION NO. 69 AND NEED SUPPLEMENT NO. 8. VESSEL ALSO NEEDS ONBOARD US COAST PILOT NO. 3. CORRECT PRIOR TO VESSEL' DEPARTURE. 33CFR164.33(a)(2)(i)
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Lifesaving
Issued 4 June 1995 Resolved
REPLACE LIFEBUOY ON THE STBD. SIDE MAIN DECK AFT OF THE PILOT HOUSE. CORRECT PRIOR TO VESSEL'S DEPARTURE. SOLAS 74_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Navigation
Issued 15 April 1994 Resolved
WHEN INSPECTED BY THE BOARDING OFFICER IT WAS NOTED THAT THE VESSEL'S MANEUVERING FACT SHEET DID NOT CONTAIN A PORT TURNING CIRCLE DIAGRAM.
Condition: Unknown
Due 18 August 1995
Resolved 18 August 1995
Navigation
Issued 20 September 1990 Resolved
THE VESSEL'S MANEUVERING FACT SHEET DID NOT HAVE THE PORT AND STARBOARD TURNING CIRCLE DIAGRAMS FOR 90 DEGREE TURNS WHICH IS REQUIRED BY 33CFR164.35(G)(1).
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.