← All vessels
VORIOS IPIROS HELLAS
VORIOS IPIROS HELLAS is a 1982 freight ship. The Coast Guard has recorded 29 inspections since 1985, most recently in July 2006, along with 65 deficiencies — 1 with no resolution recorded — and 4 operational controls.
Records from 1985 to 2006. Most recent: inspection, 1 July 2006.
- Built
- 1982
- Last inspected
- 1 July 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 65 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7433634 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H8RV
225295
Flag
PANAMA
—
Maury page id
psix-225295
Inspections, by type
…with no type recorded20
…past their stated due date1
Years with a record
8 calendar years (1985–2006)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it14029 - Regulatory (Subpart C or D), Net Ton
14029 - Convention (Subpart B), Net Ton
38097 - Dead Weight, Ton
22069 - Regulatory (Subpart C or D), Gross Ton
22069 - Convention (Subpart B), Gross Ton
14029 - Convention (Subpart B), Net Ton
38097 - Dead Weight, Ton
22069 - Regulatory (Subpart C or D), Gross Ton
22069 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
1 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2697111
12 June 2006
ISPS III Exam · PII Safety Exam · Deficiency Check · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2677200
11 September 2005
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2489588
2 September 2005
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2482768
28 March 2005
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2321902
25 March 2005
PI Safety Exam · ISPS III Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2316695
17 March 2005
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2312392
22 November 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2246317
13 October 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2220851
5 October 2004
PI Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2213662
11 August 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2163547
3 July 2004
ISPS II Exam · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2119791
24 May 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2078889
7 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2061678
7 May 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2061954
24 April 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2051487
21 April 2004
Deficiency Check · Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2048511
12 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419250
12 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394225
31 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 394030
31 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 760995
30 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 203237
18 January 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 386806
26 August 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 370022
8 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 870519
7 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367395
7 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 869457
26 November 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 362672
8 May 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 301860
Deficiency record · 65
Construction/Loadline › Structures › Door
Issued 25 March 2005
Resolved
Repair gasket and remove latch from the door between the engine room and the steering room. SOLAS 60 I/II. To the satisfaction of class.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 25 March 2005
Resolved
Fix rudder angle indicator to display correct readout as indicator is currently four degrees off. SOLAS 60 I/II. To the satisfaction of class.
Engineering › Steering Gear System › Pump
Issued 5 October 2004
Resolved
Steering gear is hunting port and starboard 3 degrees each way, Class to examine the steering gear.
Engineering › Steering Gear System › Ram
Issued 5 October 2004
Resolved
Steering gear bushings have worn due to the hunting, Class to examine bushings. Class issued requirement to be corrected no latter than 08NOV04.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 5 October 2004
Resolved
Shaft seal for emergency fire pump is leaking excessively, Class to examine the seal.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 5 October 2004
Resolved
Pipe lagging in the lower level engine room port side overhead is soaked with oil, replace to the satisfaction of Class.
Deck/Cargo › Ballast › Pumps
Issued 5 October 2004
Resolved
Ballast pump #2 shaft seal is leaking excessively, Class to examine the seal.
Electrical › Electric Generation Source (service) › Generator
Issued 5 October 2004
Resolved
Auxiliary generator #3 shaft seal is leaking an excessive amount of oil, Class to examine the seal.
Construction/Loadline › Hull › Weld
Issued 5 October 2004
Resolved
Port and starboard anchor hawser pipes are cracked; make repairs to the satisfaction of Class.
Fire Fighting › Fire Hydrants › Location/Position
Issued 5 October 2004
Resolved
Crew has removed the fire hydrant in the engine room, starboard side, and upper platform deck, in way of frame 35-40, replace the hydrant.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 5 October 2004
No resolution recorded
Prior to entry of the US Port after 8 November 2004, provide proof of dry-dock to the satisfaction of Flag administration and Class.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 5 October 2004
Resolved
While entering the Port of New York and New Jersey, the vessel is required to have tugs equal to or greater than 3785 horsepower after buoys 1nad 2.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 May 2004
Resolved
ISSUED LOD FOR INOP GYROCOMPASS
Personnel › Certificates/Documents/Licenses › License, Designated Duty Engineer
Issued 21 April 2004
Resolved
Provide Certificate of Competency from Flag State for 3rd Engineer IAW STCW.
Construction/Loadline › Markings › Load Line Mark
Issued 21 April 2004
Resolved
Loadline certificate presented to USCG Inspectors did not match marking on the hull. Provide proof that loadline survey was conducted and provide correct Load Line certificate IAW ICLL 66 reg 9.
Construction/Loadline › Structures › Ventilators
Issued 21 April 2004
Resolved
Prove proper installation of double bottom and tank side vents IAW ICLL 66 Reg 20.
Lifesaving › Launching Appliances › Block
Issued 21 April 2004
Resolved
Make permanent repairs to starboard side lifeboat davit sheeve IAW SOLAS 74 III 36(f).
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 April 2004
Resolved
Provide verification from attending Class surveyor to the fire integrity of the accommodation spaces IWO fire screen doors, door closures, and broken port bridge window IAW SOLAS 74 II-2 Reg 20.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 April 2004
Resolved
Provide additional International Shore Connection as per Fire Control Plan or update plan to reflect only one shore connection IAW SOLAS 74/78 II/2 A Reg 20.
Fire Fighting › Fire Pumps
Issued 21 April 2004
Resolved
Make permanent repairs to piping on suction side of emergency fire pump IAW SOLAS 74 I B Reg 11 and II-2 Reg 5. LEGACY COMPONENT DESC: Patches on suction side of pump
Fire Fighting › Fire Main › Condition
Issued 21 April 2004
Resolved
Make permanent repairs to fire main (numerous leaks and soft patches) IAW SOLAS 74 I-B Reg 11 and II-2 Reg 5.
Fire Fighting › Fire Pumps
Issued 21 April 2004
Resolved
Make permanent repairs to piping on the discharge side of the GS(fire) pump IAW SOLAS 74 I-B Reg 11. LEGACY COMPONENT DESC: Soft patch discharge side of piping
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 21 April 2004
Resolved
Provide operational EEBD in engine room.
Fire Fighting › Ventilation Systems › Ducts
Issued 21 April 2004
Resolved
Make permanent repairs to ventilation ducting leading to engineering spaces IAW SOLAS 74 II-2 C 45. To be completed at next drydocking. LEGACY COMPONENT DESC: Ducts
Engineering
Issued 21 April 2004
Resolved
Engine room had excessive fire hazards IWO excessive oil near purifiers and in bilge, numerous 5 gallon paint cans stowed in engine room, and improper parts cleaning containers. Remove all fire hazards. LEGACY COMPONENT DESC: General housekeeping
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 21 April 2004
Resolved
Provide Oil Transfer Procedures for vessel IAW 33 CFR 155.720.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 21 April 2004
Resolved
Provide "Discharge of Oil Prohibited" placard IAW 33 CFR 155.450.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 April 2004
Resolved
Provide records of proper maintanence for MSD and discontinue transfering sewage to #7 ballast tank IAW MARPOL Annex IV.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 21 April 2004
Resolved
Make permanent repairs and provide proper plugs for all fuel oil/lube oil containment IAW 33 CFR 155.320. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 21 April 2004
Resolved
Provide proof of pre arrival/departure tests prior to shifting from anchorage to Stockton, CA.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 21 April 2004
Resolved
Prove proper operation of ARPA IAW 33 CFR 164.38(b)(i).
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 21 April 2004
Resolved
Prove proper operation of Echo Depth Sounder and recorder IAW 33 CFR 164.35 (h).
Lifesaving › Lifeboat
Issued 21 April 2004
Resolved
Provide stays for port lifeboat mast IAW SOLAS 74 III Reg II (a)(vi) LEGACY COMPONENT DESC: Stays for mast port boat
Lifesaving › Lifeboat Equipment › Food Ration
Issued 21 April 2004
Resolved
Provide 5 food rations of 10,000 Kj ea for port lifeboat IAW SOLAS 74/78 III C 41.8.12.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 April 2004
Resolved
Provide proof of quarterly lowering and operation of lifeboats IAW SOLAS 74/78 III B 18.3.6.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 April 2004
Resolved
Make permanent repairs and prove proper operation/installation of wiring for accommodation ladder and washing machines in officers laundry IAW SOLAS 74 II-1 C 27(a)(i)(1).
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 April 2004
Resolved
Provide Class Surveyor report attesting to approved installation of bilge piping/pumping arrangement IAW MARPOL Annex I Reg 17(3).
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 April 2004
Resolved
Provide Class Surveyor report on operation of steering eductor system IAW MARPOL Annex I Reg 17(3).
Deck/Cargo › Mooring/Anchoring › Winch
Issued 21 April 2004
Resolved
Provide Class Surveyor report attesting to safe working condition of all winches IAW SOLAS 74/78 I B Reg 11.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 21 April 2004
Resolved
Make permanent repairs to all hydraulic fittings on deck IAW SOLAS 74/78 I B Reg 11. To be completed at next drydocking. LEGACY COMPONENT DESC: Other
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 21 April 2004
Resolved
Objective evidence discovered in an expanded exam revealed that the company/vessel has failed to fuly implement the requirements of the ISM Code through the Safety Management System. External audit required IAW SOLAS 74/78 IX.
Deck/Cargo
Issued 12 August 1998
Resolved
Provide class society report attesting to the satisfactory fulfillment of the outstanding requirement to effect permanent repairs to computer hardware/software in way of ability to conduct onboard calculations of cargo loading states/stresses.
Documentation
Issued 12 August 1998
Resolved
Provide evidence of written reports of non-conformities identified in the ship's Safety Management System over the audit of 15AUG98 conducted by the Safety Management Certificate issuing authority (Lloyd's Register) as required by SOLAS CH IX.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 August 1998
Resolved
Prior to return to U.S. waters, provide evidence of compliance with the requirements of Marpol V, REG 9(2) in way of Garbage Management Plan.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 August 1998
Resolved
Prior to return to U.S. waters, provide evidence of compliance with Marpol V, REG 9(3) in way of record keeping for discharge of garabage to receptionfacilities.
Engineering
Issued 12 August 1998
Resolved
Provide class society report attesting to the satisfactory completion and testing of repairs to the main diesel engine cooling water pump motor and pump packing gland assembly as per SOLAS, CH 1, REG 11.
Electrical
Issued 12 August 1998
Resolved
Prior to return to U.S. waters, provide class society report attesting to satisfactory completion and testing of repairs to Number Two Ship's ServiceGenerator as required by SOLAS CH 1, REG 11.
Deck/Cargo
Issued 12 August 1998
Resolved
In the interim period of time between now and the correction of cargo load computer hardware/software (Loadicator) as specified in PSDR Number 14 thiscase, provide onboard a means for conducting hand calculations as appropriate for safe loading and maintain all such records on file.
Electrical
Issued 12 August 1998
Resolved
All ship service generators have fuel leaks from the high pressure fuel lines.
Electrical
Issued 12 August 1998
Resolved
The number 3 ship's service generator is not to be put into service until permanent repairs are made and verified.
Electrical
Issued 12 August 1998
Resolved
The emergency generator is inoperable.
Lifesaving
Issued 12 August 1998
Resolved
Make repairs to life boat davits and provide class society certification IAW the unresolved and overdue condition of class.
Fire Fighting
Issued 12 August 1998
Resolved
Prior to return to U.S. waters, make permanent repairs and prove operation of the main fire pump in way of the burned out motor.
Lifesaving
Issued 12 August 1998
Resolved
Remove the excessive fuel oil from the ship service generator space bilges.
Fire Fighting
Issued 12 August 1998
Resolved
Provide steel core lifelines for fireman's outfits.
Lifesaving
Issued 12 August 1998
Resolved
No expiration dates or service reports for bridge wing smoke signals.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 August 1998
Resolved
Upon entry next U.S. port, provide evidence of conducting and logging steering system pre-arrival testing as required by SOLAS, CH V, REG 19.2.
Navigation
Issued 12 August 1996
Resolved
VESSEL'S ONE OF TWO RADARS IN NOT ADJUSTED PROPERLY (33CFR 164.11(r)). CORRECT PRIOR TO DEPARTURE FROM NEW ORLEANS/13AUG96.
Navigation
Issued 12 August 1996
Resolved
PROVIDE ISOLATION SWITCH ON BRIDGE FOR AUTOPILOT TO THE SATISFACTION OF CLASSIFICATION SOCIETY. (SOLAS 74 CHAPII-1 REG 29). CORRECT PRIOR TO NEXT U.S. PORT AFTER FOREIGN VOYAGE OR BY 12SEP96.
Navigation
Issued 31 July 1996
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE SREERING GEAR OPERARING AND CHANGE OVER INSTRUCTION REQ. 33 CFR 164.35 (k) WERE NOT POSRED ON THE BRIDGE._x001C_ _x001C_
Fire Fighting
Issued 31 July 1996
Resolved
A VIO SOLA 74 AMENDED CHAP 2-2 REG 4 (3) 3-2 THAT THE EMERGENCY FIRE PUMP COOLING SYSTEN AND EXHAUST SYSTEM WERE NOT IN PROPER WORKING CONDITION._x001C_ _x001C_ CORRECTED PRIOR TO DEPARTURE.
Navigation
Issued 18 January 1996
Resolved
MAKE PERMANENT REPAIRS TO THE STEERIN GEAR RAM WHERE IT HAS PULLED FROM THERUDDER STOCK COUPLING._x001C_ _x001C_ SOLAS 74 II-I/29
Navigation
Issued 8 May 1985
Resolved
FAILURE TO PROVIDE A WORKING MARINE SURFACE RADAR SYSTEM UPON ENTRY INTO THE PORT OF GEORGETOWN SC WHICH IS IN THE COTP OF CHARLESTON ZONE. 33CFR164.35(A)
Navigation
Issued 8 May 1985
Resolved
FAILURE TO NOTIFY THE COTP THAT SECONDARY RADAR WAS NOT OPERATING PROPERLY BEFORE ENTERING THE PORT OF GEORGETOWN SC,WHICH IS IN THE COTP OF CHARLESTON ZONE.33CFR164.53(B)
Navigation
Issued 8 May 1985
Resolved
FAILURE TO PROVIDE MOST RECENT OR CURRENTLY CORRECTED US COAST PILOT VOL.4 OR EQUIVALANT.33CFR164.33(A)(2)(I)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.