← All vessels
ELXIS
ELXIS is a 1976 freight ship. The Coast Guard has recorded 11 inspections since 1988, most recently in July 2003, along with 11 deficiencies and 1 operational control.
Records from 1988 to 2003. Most recent: inspection, 1 July 2003.
- Built
- 1976
- Last inspected
- 1 July 2003
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7435474 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FKU9
225310
Flag
GREECE
—
Maury page id
psix-225310
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it8832 - Convention (Subpart B), Net Ton
22669 - Dead Weight, Ton
28346 - Displacement, Ton
13661 - Convention (Subpart B), Gross Ton
22669 - Dead Weight, Ton
28346 - Displacement, Ton
13661 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
1 July 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1838845
10 June 2003
Annual Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1814272
5 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1811586
14 January 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 495833
27 January 1993
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 356190
19 August 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 645304
16 August 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 352567
10 August 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 332002
14 March 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 520657
1 July 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 507954
27 June 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324166
Deficiency record · 11
Engineering › Diesel Engine (auxiliary)
Issued 10 June 2003
Resolved
No. 1 diesel auxiliary generator sea water cooling pump gasket/seal leaking excessively. LEGACY COMPONENT DESC: Sea water cooling pump
Fire Fighting › Fire Pumps
Issued 10 June 2003
Resolved
Emergency fire pump, priming pump gasket leaking excessively. LEGACY COMPONENT DESC: Pressure
Pollution Prevention/Response › Prevention Equipment
Issued 10 June 2003
Resolved
Oily water separator system piping has been altered from original design. Oily-water mixture of greater than 15ppm is being pumped directly into engineroom bilges vice the bilge holding tank. Prohibit use of the Oily water separator in U. S. water until repaired to the satisfaction of class. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Pollution Prevention/Response › Prevention Equipment
Issued 10 June 2003
Resolved
Oily water separator monitor does not function as per system design. During test of the oily water separator unit, when the light and audible alarm sound to indicate greater than 15ppm the graphic display indicates 0ppm. When the monitor indicates less than 15ppm, display indicates 20ppm. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Navigation
Issued 16 August 1992
Resolved
VESSEL FAILED TO RECORD PRE-ARRIVAL TESTS IN SHIPS DECK LOG
Navigation
Issued 27 June 1988
Resolved
VESSEL'S CHART 18521 HAD NO CORRECTIONS.
Navigation
Issued 27 June 1988
Resolved
VESSEL'S CHART 18523 HAD NO CORRECTIONS.
Navigation
Issued 27 June 1988
Resolved
VESSEL'S CHART 18524 HAD NO CORRECTIONS.
Navigation
Issued 27 June 1988
Resolved
VESSEL'S LIGHT LIST HAD NO CORRECTIONS.
Navigation
Issued 27 June 1988
Resolved
VESSEL FAILED TO NOTIFY THE COTP OF IT'S INOP RADAR.
Documentation
Issued 27 June 1988
Resolved
VESSEL'S O.T.P. WERE INCOMPLETE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National