MAURY USCG vessel records Sign in
← All vessels

KENMARE

KENMARE is a 1975 freight ship. The Coast Guard has recorded 25 inspections since 1984, most recently in December 2002, along with 39 deficiencies and 2 operational controls.

Records from 1984 to 2002. Most recent: inspection, 9 December 2002.

Built
1975
Last inspected
9 December 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7501819 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225338
Flag
CYPRUS
—
Maury page id
psix-225338

Inspections, by type

…with no type recorded22
Years with a record 15 calendar years (1984–2002)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2891 - Regulatory (Subpart C or D), Net Ton
8110 - Dead Weight, Ton
11244 - Displacement, Ton
5306 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

B-12 Tank Barge · MISLE 50459 · 20 April 1994 · activity 513622

Inspection history · 25

9 December 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1717098
6 November 2002 Annual Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1701883
5 June 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1626726
28 September 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293949
20 September 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 280757
20 October 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 434310
12 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426426
4 June 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 416619
30 November 1997 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 410450
12 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398417
6 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398346
24 April 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 390317
22 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 648460
18 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381959
30 January 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 374643
12 August 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 369238
20 April 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 513622
20 April 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 648461
21 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355792
23 January 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 341492
9 November 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 333622
18 December 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 521212
23 February 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 321547
2 July 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 310045
16 August 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 297402

Deficiency record · 39

Fire Fighting › Emergency Fire Pumps
Issued 6 November 2002 Resolved
The emergency fire pump could not produce two streams of water. LEGACY COMPONENT DESC: Pressure
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2002
Resolved 13 November 2002
Resolution: Received a class report from [name withheld] stating that the emergency fire pump and vacuum pump were overhauled and tested with satisfactory results. Cleared the deficiency and released the vessel from restriction.
Engineering › Generator (propulsion-electric)
Issued 6 November 2002 Resolved
The No. 2 generator has a spraying oil leak on the #4 injection pump- Cleared prior to Boading team departing vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 November 2002
Resolved 6 November 2002
Resolution: Boarding team witnessed repairs prior to departing the vessel.
Engineering › Bilge Water Management System
Issued 6 November 2002 Resolved
Both generator catch basins below fly wheels are filled with water and oil. Remove and clean.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 November 2002
Resolved 13 November 2002
Resolution: Received a class report from [name withheld] stating that oil and water were removed. Cleared the deficiency.
Engineering › Fuel Oil Service System
Issued 6 November 2002 Resolved
The purifier bilge is laden with fuel oil and oil soaked rags. Remove and clean.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2002
Resolved 9 December 2002
Resolution: Area cleaned by crew and inspected by attending USCG inspector- all sat.
Pollution Prevention/Response › Prevention Equipment
Issued 5 June 2002 Resolved
SOFT PATCH FOUND ON INLET PIPE TO OWS, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Boarding team witnessed repaired pipe.
Pollution Prevention/Response › Prevention Equipment
Issued 5 June 2002 Resolved
SEWAGE TANK WASTED AND LEAKING, REPAIR TO SATISFACTION OF FLAG STATE. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Received class report stating: MSD cleaned and repaired. Boarding team witnessed no leaks.
Pollution Prevention/Response › Prevention Equipment
Issued 5 June 2002 Resolved
SEWAGE TANK MISSING APPROVAL PLACKARD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper Installation
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating plackard had been cleaned.
Personnel › Certificates/Documents/Licenses
Issued 5 June 2002 Resolved
PROVIDE COPY OF 2ND MATES LICENSE. LEGACY COMPONENT DESC: License, Second Mate
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: PROVIDED
Engineering › Shafting/Propeller Arrangements
Issued 5 June 2002 Resolved
SHAFT SEAL LEAKING EXCESSIVELY, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Stern Gland
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR OF SHAFT SEAL.
Engineering › Lubricating Oil Service System
Issued 5 June 2002 Resolved
LUBE OIL COOLER WATER INLET PIPE HOLED AND WASTED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating pipe has been repaired. Boarding team witnessed pipe repair.
Accommodation/Occupational Safety › Potable Water System
Issued 5 June 2002 Resolved
COOLING WATER AND EVAP PUMP DISCHARGE VALVES WASTED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: EVAP
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating valve has been renewed. Boarding team witnessed new valve.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 June 2002 Resolved
GUARD RAIL ON MAIN SERVICE GENERATOR BROKEN, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating guard rail has been welded. Boarding team witnessed the repair.
Engineering › Freshwater System (jacketwater cooling)
Issued 5 June 2002 Resolved
MAIN COOLING WATER PUMPS 1 AND 2 LEAK EXCESSIVELY, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR.
Engineering › Sea-water System (primary cooling)
Issued 5 June 2002 Resolved
MAIN S/W COOLING PUMPS LEAK EXCESSIVELY AND FOUNDATION WASTED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Boarding team witnessed no leaks.
Engineering › Sea-water System (primary cooling)
Issued 5 June 2002 Resolved
SUPPORT SERVICE PUMP LEAKS EXCESSIVELY AND SEA STRAINER NEXT TO PUMP ALSO LEAKS, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Boarding team witnessed repair of pump.
Fire Fighting › Fire Pumps
Issued 5 June 2002 Resolved
GS/FIRE PUMP LEAKING EXCESSIVELY, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Gland Sealing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR AND OPERATION OF PUMP.
Deck/Cargo › Ballast
Issued 5 June 2002 Resolved
BALLAST DISCH OVBD VALVE LEAKS, CLASS TO INSPECT AND PROVIDE REPAIR PROPOSAL PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: CLASS ATTESTED TO THE PROPER REPAIR AND OPERATION.
Engineering › Freshwater System (jacketwater cooling)
Issued 5 June 2002 Resolved
DOUBLER FOUND ON JACKET WATER COOLER, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating pipe renewed. Boarding team witnessed repair.
Engineering › Compressed Air System (start air)
Issued 5 June 2002 Resolved
PIPE ABOVE MAIN AIR RESIVOIR HOLED AND WASTED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating pipe renewed. Boarding team witnessed pipe repair.
Engineering › Compressed Air System (start air)
Issued 5 June 2002 Resolved
PIPING NEXT TO MAIN AIR RESIVOIR HAS NUMEROUS DOUBLERS, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2002
Resolved 6 November 2002
Resolution: Rcvd'' class report stating pipe renewed. Boarding team witnessed new pipe.
Engineering › Bilge Water Management System
Issued 5 June 2002 Resolved
EXCESSIVE OIL IN BILGES. CLEAN PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Resolution: CLASS ATTESTED TO THE CLEANING OF THE BILGES AND ENGINE ROOM.
Navigation
Issued 28 September 2001 Resolved
RUDDER ANGLE INDICATOR ON BRIDGE DID NOT MATCH SAME POSITION IN STEERING ROOM. INDICATOR NEEDED TO BE ADJUSTED TO READ SAME ANGLE IN BOTH COMPARTMENTS. TRANSMITTER CLEANED AND GREASED. CLASS ATTESTED TO SATISFACTORY RESULTS.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Navigation
Issued 20 September 2000 Resolved
Rudder angle indicator not operating properly. Class society to attest to proper operation._x001C_ SOLAS 60 II/29(IV)
Condition: Unknown
Due 30 October 2000
Resolved 1 December 2000
Resolution: CLASS REPORT STATED TRANSMITTER WAS CLEANED AND GREASED.
Lifesaving
Issued 20 October 1999 Resolved
REMOVE ALL OILY RAGS FROM ENGINEROOM._x001C_ _x001C_ SOLAS 60 II/34.3
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Lifesaving
Issued 20 October 1999 Resolved
REMOVE ALL OIL FROM THE BILGES._x001C_ _x001C_ SOLAS 60 II/34.3
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Accommodation/Occupational Safety
Issued 20 October 1999 Resolved
CLEAN ENGINE ROOM DECK PLATES FREE OF OIL._x001C_ _x001C_ SOLAS 74 II-1/26.1
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Navigation
Issued 20 October 1999 Resolved
REMOVE EXCESS GREASE AND OIL FROM STEERING GEAR CONTAINMENT._x001C_ _x001C_ SOLAS 60 II/34.3_x001C_ _x001C_
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Fire Fighting
Issued 12 December 1996 Resolved
PERFORM TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR ASATISFACTORY FIRE AND ABANDON SHIP DRILL._x001C_ SEE SOLAS 74 (AMENDED) III/18.3.4-3,9 AND 18.3.10-3.13.
Condition: Unknown
Due 13 December 1996
Resolved 16 December 1996
Lifesaving
Issued 12 December 1996 Resolved
PROVIDE FOR STARBOARD LIFEBOAT AN APPROVED COVER OF A HIGHLY VISIBLE COLOR CAPABLEOF PROTECTING THE OCCUPANTS AGAINST EXPOSURE._x001C_ SEE SOLAS 60 III/11.
Condition: Unknown
Due 13 December 1996
Resolved 16 December 1996
Navigation
Issued 12 December 1996 Resolved
REPAIR / CALIBRATE THE RUDDER ANGLE INDICATOR LOCATED ON THE BRIDGE TO MATCH THE RUDDER ANGLE INDICATOR IN THE STEERING GEAR ROOM._x001C_ SEE SOLAS 74 (AMENDED) V/12(M)
Condition: Unknown
Due 13 December 1996
Resolved 16 December 1996
Fire Fighting
Issued 12 December 1996 Resolved
PROVIDE ADEQUATE RUBBER BOOTS FOR FIREMAN'S OUTFIT._x001C_ SEE SOLAS 74 AMENDED II-2/17.1.1
Condition: Unknown
Due 13 December 1996
Resolved 16 December 1996
Fire Fighting
Issued 12 December 1996 Resolved
RENEW THE HOLED FIREMAN'S OUTFIT._x001C_ SEE SOLAS 74 (AMENDED) II-2/17.1.1
Condition: Unknown
Due 13 December 1996
Resolved 16 December 1996
Fire Fighting
Issued 24 April 1996 Resolved
On deck vent from steering gear compartment holed. ICLL 66 RS. 19
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Engineering
Issued 24 April 1996 Resolved
FUEL OIL SUPPLY PIPING FOR MAIN ENGINE IN PURIFIER ROOM HAS A TEMPORARY REPAIR.
Condition: Unknown
Due 16 December 1996
Resolved 16 December 1996
Navigation
Issued 18 August 1995 Resolved
Provide Radiotephone capable of transmitting and receiving on VHF channel 22A.
Condition: Unknown
Due 19 August 1995
Resolved 22 August 1995
Documentation
Issued 21 January 1993 Resolved
VESSEL COULD NOT PRODUCE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 21 January 1993
Resolved 22 January 1993
Unknown
Issued 16 August 1984 Resolved
VESSEL DID NOT HAVE PROPER DICHARGE CONTAINMENT, A VIOLATION OF 33 CFR 155.320 (A)(2).
Condition: Unknown
Due 16 August 1984
Resolved 16 August 1984
Documentation
Issued 16 August 1984 Resolved
VESSEL DID NOT HAVE DESIGNATED PERSON-IN-CHARGE OF OIL TRANSFER PROCEDURES,A VIOLATION OF 33 CFR 155.700/33 USC 1321 (J)(1).
Condition: Unknown
Due 16 August 1984
Resolved 16 August 1984
Documentation
Issued 16 August 1984 Resolved
THE PROPER RECORDS REQUIRED WERE NOT AVAILABLE FOR INSPECTION, A VIOLATION OF 33 CFR 155.820/33 USC 1321(J)(1).
Condition: Unknown
Due 16 August 1984
Resolved 16 August 1984

Ownership record