MAURY USCG vessel records Sign in
← All vessels

ILONA

ILONA is a 1979 tank ship. The Coast Guard has recorded 44 inspections since 1985, most recently in January 2006, along with 27 deficiencies and 10 operational controls.

Records from 1985 to 2006. Most recent: inspection, 18 January 2006.

Built
1979
Last inspected
18 January 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7504079 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225367
Flag
LIBERIA
—
Maury page id
psix-225367

Inspections, by type

…with no type recorded30
Years with a record 13 calendar years (1985–2006)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11975 - Convention (Subpart B), Net Ton
30990 - Dead Weight, Ton
38250 - Displacement, Ton
18101 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 44

18 January 2006 Deficiency Check · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2568714
17 January 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2568512
13 October 2005 PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2513548
17 July 2005 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2422681
14 May 2005 ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2357434
14 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2309919
9 March 2005 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2306719
8 March 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2305783
7 March 2005 Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2304889
7 March 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2305039
6 March 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2304477
4 March 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2303416
30 November 2004 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2250226
21 November 2004 Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2245224
12 October 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2215619
12 October 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2219578
3 May 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 502083
17 August 1993 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 846548
1 December 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 648057
5 October 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 648058
5 October 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 648059
5 August 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 97822
5 August 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 188303
1 August 1992 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 352455
1 August 1992 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1253029
27 September 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 457431
4 March 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 342256
4 March 1991 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 933416
27 February 1990 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1214791
16 February 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 335367
15 September 1989 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 521871
14 February 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 328489
14 February 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347719
30 November 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 327094
14 October 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 326138
18 July 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 451582
17 February 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 321359
17 February 1988 Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328584
22 July 1987 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 317467
30 June 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 470324
24 November 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 312920
24 November 1986 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1328760
29 March 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 448515
13 November 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305333

Deficiency record · 27

Lifesaving › Launching Appliances › Davit
Issued 30 November 2004 Resolved
PORT LIFEBOAT DAVIT HAS SEVERE WASTAGE AT THE AFT ROUND BAR ATTACHED TO HOUSE AND FORWARD ROUND BAR DAVIT STOP
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Lifesaving › Launching Appliances › Davit
Issued 30 November 2004 Resolved
STARBOARD LIFEBOAT DAVIT HAS SEVERE WASTAGE IN THE DAVIT ARM HEAD AT THE FALLS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Fire Fighting › Fire Main › Condition
Issued 30 November 2004 Resolved
FIREMAIN IN THE FORECASTLE HAS MULTIPLE HOLES AND ONE SOFT PATCH. IN ADDITION THERE ARE MULTIPLE AREAS OF SEVERE WASTAGE IN FIREMAIN ON DECK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Lifesaving › Launching Appliances › Davit
Issued 30 November 2004 Resolved
PORT AND STARBOARD LIFEBOAT DAVIT LIMIT SWITCHES ARE MISSING/INOPERABLE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 30 November 2004 Resolved
RUDDER POST ON PORT LIFEBOAT IS WASTED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 30 November 2004 Resolved
HATCH TO THE BOSUN HOLE IS WASTED/HOLED ON FORWARD OUTBOARD CORNER.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 November 2004 Resolved
EMERGENCY FIRE PUMP EXHAUST IS LEAKING INTO BOSUN HOLE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Fire Fighting › Fire Hydrants › Condition
Issued 30 November 2004 Resolved
ALL FIRE HYDRANTS ON DECK ARE LEAKING AT VALVE STEMS AND/OR SEATS. .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Construction/Loadline › Structures › Door
Issued 30 November 2004 Resolved
FIREDOORS ON MAIN STAIRTOWER DO NOT CLOSE. ADJUST AS NECESSARY TO PROVIDE FOR PROPER CLOSURE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 30 November 2004 Resolved
MOORING LINES WASTED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Construction/Loadline › Structures › Ventilators
Issued 30 November 2004 Resolved
VENT PIPE FOR NO. 1 PORT CARGO TANK IS SOFT PATCHED/HOLED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Engineering › Freshwater Generation System › Piping
Issued 30 November 2004 Resolved
FRESHWATER GENERATOR OVERBOARD PIPE IS LEAKING AND HAS A TEMPORARY REPAIR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Resolution: Vessel issued condition of class for this item.
Engineering › Freshwater Generation System › Piping
Issued 30 November 2004 Resolved
FRESHWATER GENERATOR END COVER IS LEAKING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 30 November 2004 Resolved
OVERBOARD GREY WATER PIPE IN ENGINEROOM IS LEAKING NEAR ELECTRICAL BOX.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2004
Resolved 3 December 2004
Resolution: Vessel issued condition of class.
Lifesaving › Lifeboat › Hull
Issued 21 November 2004 Resolved
Replace self-bailing plug stoppers to satisfaction of class, prior to departure, both port and starboard lifeboats.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2004
Resolution: received class report verification.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 12 October 2004 Resolved
Have Minimum Safe Manning Document reviewed by flag administration to reflect new ship classification.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 21 November 2004
Resolution: New document was issued on 5Nov04. Original was onboard. Copy was added to file.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 12 October 2004 Resolved
Make repairs to the satisfaction of class surveyor of Main Bunkering Fuel Oil line rubber expansion located STBD side FWD of Boom.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Resolution: Received surveyor report attesting to satisfactory repairs.
Deck/Cargo › Cargo Heating › General
Issued 12 October 2004 Resolved
Make repairs to the satisfaction of class surveyor of cargo steam line wasted and holed located STBD side and aft of boom.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Resolution: Received surveyor report attesting to satisfactory repairs.
Lifesaving › Lifebuoys › Immediately Available
Issued 12 October 2004 Resolved
Replace lifebouy on STBD bow as per requirements and satisfaction of class surveyor.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Resolution: Received surveyors report attesting to satisfactory repairs.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 October 2004 Resolved
Repair or replace railing on STBD bow to satisfaction of class surveyor.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Resolution: Received surveyor report attesting to satisfactory repair.
Engineering › Fuel Oil Service System › Filter
Issued 12 October 2004 Resolved
Have class surveyor attest to proper repair work made by ship's crew to #1 Ship's Service Diesel Generator (SSDG) High Pressure Fuel Oil Strainer inlet pipe.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2004
Resolution: Received surveyors report attesting to satisfactory repairs.
Fire Fighting › Fire Hoses › Condition
Issued 12 October 2004 Resolved
Repair firehose box cover located portside on boat deck aft of port life boat to the satisfaction of class surveyor.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 November 2004
Resolved 21 November 2004
Resolution: Attended VSL and observed repairs that had been completed to rebuild the box.
Navigation
Issued 27 February 1990 Resolved
REPAIR ECHO DEPTH SOUNDER.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Unknown
Issued 16 February 1990 Resolved
33 CFR 164.53(B) IF THE VESSELS ECHO DEPTH SOUNDING DEVICE STOPS OPERATING PROPERLY, THE PERSON DIRECTING THE MOVEMENT OF THE VESSEL MUST REPORT OR CAUSE TO BE REPORTED THAT IT IS NOT OPERATING PROPERLY TO THE NEAREST COTP.(THE CAPTAIN OF THE VESSEL DID NOT REPORT INOPERABLE ECHO DEPTH SOUNDER).
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Unknown
Issued 16 February 1990 Resolved
33 CFR 164.35(H)(I) EACH VESSEL MUST HAVE THE FOLLOWING: AN ECHO DEPTH SOUNDING DEVICE. A DEVICE WHICH CAN CONTINUOUSLY RECORD THE DEPTH READING OF THE VESSLES ECHO DEPTH SOUNDING DEVICE. THE TRANSISTED COTP BOSTON ZONE WITHOUT AN OPERABLE ECHO DEPTH SOUNDING DEVICE.
Condition: Unknown
Due 16 February 1990
Resolved 16 February 1990
Navigation
Issued 14 October 1988 Resolved
33 CFR 164.37(A) THE VESSEL WICH WAS OVER 10,000 GROSS TONS, DID NOT HAVE ON BOARD AN OPERABLE SECOND MARINE RADAR SYSTEM.
Condition: Unknown
Due 14 October 1988
Resolved 14 October 1988
Deck/Cargo
Issued 13 November 1985 Resolved
RENEW FLAME SCREENS ON P/V'S ALL CARGO TANKS (21).
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.