Records from 1984 to 2001. Most recent: operational control imposed, 29 January 2001.
Inspection history · 46
29 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286272
14 July 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279998
14 July 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766347
13 July 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279941
12 July 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 204864
20 January 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 273671
20 July 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430736
2 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426009
7 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 421121
12 August 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 419097
9 April 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 414560
15 February 1998
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 412836
12 February 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412789
9 February 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 412531
14 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405817
9 July 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 186565
1 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401062
5 January 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 129594
20 August 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 394286
8 August 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 394068
20 April 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 390453
27 February 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 705584
26 February 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 388096
24 August 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381949
29 June 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 380025
29 March 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 376586
18 September 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 370583
12 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493190
9 June 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 367537
9 June 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1323328
6 July 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359287
14 March 1993
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 356948
25 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354589
24 July 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 523312
17 March 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 538678
19 November 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 347104
23 July 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 338448
4 October 1989
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 332859
3 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328778
2 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 319380
18 August 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 506938
5 March 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314642
7 July 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 309929
15 November 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 455572
29 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302220
11 May 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 449278
Accommodation/Occupational Safety
Issued 29 January 2001
No resolution recorded
REPAIR LADDER RAIL IN UPPER ENGINE ROOM. ILLC ANNEX I/15
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 29 January 2001
No resolution recorded
REPLACE WASTED DECK PLATING IN WAY OF #3 GENERATOR SET AND AFT OF OILY WATER SEPERATOR IN ENGINE ROOM. ILLC ANNEX I/15
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001
No resolution recorded
REPAIR AS ORIGINAL WASTED AREA IN OVERHEAD INSIDE EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 29 January 2001
No resolution recorded
REPLACE/REPAIR SOFT PATCH ON AIR CONDITIONING PIPING IN ENGINE ROOM. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001
No resolution recorded
REPAIR LEAK ON SMALL DIAMETER FILL LINE FOR OILY WATER SEPARATOR. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Electrical
Issued 29 January 2001
No resolution recorded
REPAIR SOFT HOSE ON #3 GENERATOR SET IN WAY OF JACKET WATER COOLING PIPING.SOLAS 60 I/11
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001
No resolution recorded
REPAIR LEAK ON OILY WATER SEPERATOR INLET PIPING. SOLAS 60 I/11
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001
No resolution recorded
REPAIR SOFT PATCH ON MAIN FIRE PUMP SUCTION. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001
No resolution recorded
REPAIR LEAK IN #1 PISTON BILGE PUMP. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Electrical
Issued 29 January 2001
No resolution recorded
REPLACE CRACKED LIGHT COVER IN UPPER ENGINE ROOM LIGHT SHINES DOWN ON CYLINDER BLOCK. SOLAS 60 II/27
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001
No resolution recorded
#2 SALTWATER COOLING PUMP FOR MAIN ENGINE HAS CEMENT PATCH ON INTAKE PIPE LOCATED AT BASE OF PUMP. PATCH IS SPLIT AND LEAKING EXCESSIVELY, YET, NOT FOUND TO BE A DIRECT HAZARD TO OPERATION OF MAIN ENGINE. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001
No resolution recorded
SALTWATER COOLING LINES EXCESSIVELY CORRODED, SOME HAVE JUBILEE PATCHES. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001
No resolution recorded
ALL FIRE FIGHTING NOZZLES IN ENGINE ROOM ARE STRAIGHT STREAM AND NEED TO BEREPLACED WITH MULTI-PURPOSE NOZZLES. SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001
Resolved
FIRE EXTINGUSHER MISSING FROM STATION #17. SOLAS 74 (AMENDED) II-2
Condition: Unknown
Due 1 March 2001
Resolved 31 January 2001
Navigation
Issued 29 January 2001
No resolution recorded
PERMANENTLY REPAIR ECHO DEPTH SOUNDING DEVICE TO SATISFACTION OF ATTENDING CLASS SOCIETY SURVEYOR. TO BE COMPLETED NO LATER THAN MARCH 2002 IN DRYDOCKTEMPORARY ECHO DEPTH SOUNDING DEVICE TO REMAIN OPERATIONAL IN U.S. WATERS.33CFR 164.35(i)
Condition: Unknown
Due 1 March 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001
No resolution recorded
REPAIR AS ORIGINAL CEMENT PATCH IN WAY OF DECK IN REAR OF CO2 ROOM. ILLC 66ANNEX I/1
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001
No resolution recorded
REPAIR AS ORIGINAL EXCESSIVE WASTAGE ON STARBOARD GUNWALES. ILLC 66 ANNEX I/15
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001
No resolution recorded
REPAIR AS ORIGINAL REMOTE FUEL SHUTOFF TO EMERGENCY GENERATOR. SOLAS 60 II/69
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Navigation
Issued 13 July 2000
Resolved
MISSING BLOCK DIAGRAM IN STEERING CONTROL ROOM.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Lifesaving
Issued 13 July 2000
Resolved
MISSING RETRO-REFLECTIVE TAPE ON RING BOUYS FOR PORT AND STBD.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Documentation
Issued 13 July 2000
Resolved
SAFETY EQUIPMENT CERTIFICATE EXPIRED.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 13 July 2000
Resolved
REMOVE FLAMMABLES IN ENGINE ROOM TO FLAMMABLE LOCKER.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 13 July 2000
Resolved
VENT CLOSURES RUSTED.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Fire Fighting
Issued 13 July 2000
Resolved
SEMI-PORTABLE FIE EXTINGUSHERS IN ENGINE ROOM EXPIRED.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Navigation
Issued 13 July 2000
Resolved
MISSING COMMUNICATIONSFROM STEERING CONTROL ROOM TO BRIDGE.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Construction/Loadline
Issued 13 July 2000
Resolved
DOORS NOT WATERTIGHT. PROVIDE CLASS SOCIETY REPORT TO THIS COTP PRIOR TO DEPARTURE.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 12 August 1998
Resolved
Ship's service fire pump has a leaking valve on the pump's supply side._x001C_
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 12 August 1998
Resolved
Ship's deck on the port side of fantail, over the steering space, is in wasted condition.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 12 August 1998
Resolved
Excess oil located in emergency generator space, steering space, and engineroom.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Documentation
Issued 9 February 1998
Resolved
NO CARGO SECURING MANUAL AVAILABLE. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 9 February 1998
Resolved
EMERGENCY GENERATOR WOULD NOT START THE REQUIRED THREE TIMES.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Engineering
Issued 9 February 1998
Resolved
NO FLAME SCREENS PRESENT IN FUEL OIL VENTS. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 9 February 1998
Resolved
S/S GENERATOR LUBE OIL COOLING LINE HAS TEMPORARY REPAIRS. PROVIDE CLASS ATTESTATION AS TO CONDITION PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Engineering
Issued 9 February 1998
Resolved
MAIN ENGINE SALTWATER COOLING LINE HAS MULTIPLE REPAIRS. PROVIDE CLASS ATTESTAION AS TO CONDITION PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Lifesaving
Issued 9 February 1998
Resolved
NUMEROUS MEDICAL SUPLIES OUTDATED. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 8 August 1996
Resolved
PROVIDE OPERABLE WATERLIGHT P/S BRIDGE WING PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 8 August 1996
Resolved
REPAIR/REPLACE PORT SIDE LIFEBOAT GRABRAIL PRIOR TO DEPARTURE PORT OF MOREHEAD CITY, NC._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996
Resolved
PROVIDE WRITTEN CLASS ATTESTATION AS TO GENERAL CONDITION OF FIRE MAIN PIPING THROUGHOUT VESSEL PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Construction/Loadline
Issued 8 August 1996
Resolved
REPAIR/REPLACE WATER TIGHT DOOR MAIN DECK FWD OF HOUSE PRIOR TO RETURN TO NEXT U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Fire Fighting
Issued 8 August 1996
Resolved
REPAIR/REPLACE FIREMAIN PIPING MAIN DECK AT FOSCLE AND AT PORT SIDE AND STARBOARD SIDE AHEAD OF HOUSE PROVIDE WRITTEN CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996
Resolved
INSURE FIREHOSES ARE IN APPROPRIATE PLACES ACCORDING TO FIRE PLAN PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996
Resolved
VALVE (FIRE PROTECTION) TO PAINT LOCKER SYSTIM NOT OPERATIONAL, REPAIR/REPLACE AND PROVIDE WRITTEN CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 8 August 1996
Resolved
REPAIR/REPLACE FWD LIMIT SWITCH ON P/S LIFEBOAT DAVIT AND PROVIDE CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 26 February 1996
Resolved
Vessel to provide a quick release arrangement for the bridgewing lifebuoys as required by Solas chapter 3, Regulation 7. Compliance date of 15 APR 96 issued.
Condition: Unknown
Due 21 April 1996
Resolved 21 April 1996
Documentation
Issued 26 February 1996
Resolved
Vessel personnel could not provide a oil record book with proper entries recording the incineration of bilge slops. Vessel's O.R.B. indicated bilgespumped to slop tank, no reference to draining slop tank. Vessel given compliance date of 15 APR 96 to establish a history of proper log entries.
Condition: Unknown
Due 21 April 1996
Resolved 21 April 1996
Engineering
Issued 29 June 1995
Resolved
VSL TO PROVIDE FLAME SCREENS FOR FUEL OIL VENTS ON DECK.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Navigation
Issued 29 June 1995
Resolved
VSL HAS NO LARGE SCALE CHART FOR AREA TRANSITTED.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Documentation
Issued 29 June 1995
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE TRANSFER PROCEDURES IN CREW'S_x001C_ NATIVE LANGUAGE. (E.G. RUSSIAN)_x001C_
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Accommodation/Occupational Safety
Issued 29 June 1995
Resolved
PROVIDE CLASS/FLAG STATE APPROVAL OF MSD PRIOR TO RETURN NEXT U.S. VOYAGE.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Engineering
Issued 29 June 1995
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION OF_x001C_ TEMP REPAIR (CEMENT BOX PATCH) TO M/E FRESHWATER COOLING LINE DISCHARGE.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Fire Fighting
Issued 29 June 1995
Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, INSTALL PRESS GUARGE TO #2 FIRE PUMP.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Fire Fighting
Issued 29 June 1995
Resolved
BEFORE SAILING FOREIGN A RECENT SERVICE REPORT (WITHIN 2 YEARS) OF VSL'S_x001C_ FIXED/PORTABLE F/F SYSTEMS.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Documentation
Issued 14 March 1993
Resolved
The Atlantic Clipper, a vessel with a capacity of greater than 250 barrels of il, failed to have complete oil transfer procedures in that the piping diagram was not posted.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Documentation
Issued 2 November 1987
Resolved
33CFR155.720 THE OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS WERE INCOM- PLETE.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 2 November 1987
Resolved
33CFR164.33(A)(2)(II) NO LIGHT LIST VOLUME IV ONBOARD.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 2 November 1987
Resolved
33CFR164.33(A)(3)(II) NO TIDAL CURRENT TABLES ONBOARD.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 7 July 1986
Resolved
THE VESSEL DID NOT HAVE A COPY OF THE U.S. TIDAL CURRENT TABLES OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986
Navigation
Issued 7 July 1986
Resolved
THE VESSEL DID NOT HAVE MANUEUVERING INFORMATION FOR FULL AND HALF SPEEDS POSTED ON THE BRIDGE
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986
Navigation
Issued 7 July 1986
Resolved
THE VESSELS DID NOT HAVE OPERATING INSTRUCTIONS AND SIMPLE BLOCK DIAGRAM FOR EMERGENCY STEERING CHANGEOVER PROCEEDURES POSTED ON THE BRIDGE
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986