MAURY USCG vessel records Sign in
← All vessels

CLIPPER ATLANTIC

CLIPPER ATLANTIC is a 1975 freight ship. The Coast Guard has recorded 46 inspections since 1984, most recently in January 2001, along with 59 deficiencies — 17 with no resolution recorded — and 2 operational controls.

Records from 1984 to 2001. Most recent: operational control imposed, 29 January 2001.

Built
1975
Last inspected
29 January 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7506974 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225387
Flag
GERMANY
—
Maury page id
psix-225387

Inspections, by type

…with no type recorded46
…past their stated due date17
Years with a record 17 calendar years (1984–2001)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3004 - Regulatory (Subpart C or D), Net Ton
7951 - Dead Weight, Ton
6157 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 46

29 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286272
14 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279998
14 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 766347
13 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279941
12 July 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 204864
20 January 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 273671
20 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 430736
2 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426009
7 October 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 421121
12 August 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 419097
9 April 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 414560
15 February 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 412836
12 February 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412789
9 February 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 412531
14 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405817
9 July 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 186565
1 March 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401062
5 January 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 129594
20 August 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 394286
8 August 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 394068
20 April 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 390453
27 February 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 705584
26 February 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 388096
24 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381949
29 June 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 380025
29 March 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 376586
18 September 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 370583
12 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493190
9 June 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 367537
9 June 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1323328
6 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359287
14 March 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 356948
25 November 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354589
24 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 523312
17 March 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 538678
19 November 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 347104
23 July 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 338448
4 October 1989 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 332859
3 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328778
2 November 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 319380
18 August 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 506938
5 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314642
7 July 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 309929
15 November 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 455572
29 May 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302220
11 May 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 449278

Deficiency record · 59

Accommodation/Occupational Safety
Issued 29 January 2001 No resolution recorded
REPAIR LADDER RAIL IN UPPER ENGINE ROOM. ILLC ANNEX I/15
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 29 January 2001 No resolution recorded
REPLACE WASTED DECK PLATING IN WAY OF #3 GENERATOR SET AND AFT OF OILY WATER SEPERATOR IN ENGINE ROOM. ILLC ANNEX I/15
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001 No resolution recorded
REPAIR AS ORIGINAL WASTED AREA IN OVERHEAD INSIDE EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 29 January 2001 No resolution recorded
REPLACE/REPAIR SOFT PATCH ON AIR CONDITIONING PIPING IN ENGINE ROOM. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001 No resolution recorded
REPAIR LEAK ON SMALL DIAMETER FILL LINE FOR OILY WATER SEPARATOR. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Electrical
Issued 29 January 2001 No resolution recorded
REPAIR SOFT HOSE ON #3 GENERATOR SET IN WAY OF JACKET WATER COOLING PIPING.SOLAS 60 I/11
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001 No resolution recorded
REPAIR LEAK ON OILY WATER SEPERATOR INLET PIPING. SOLAS 60 I/11
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001 No resolution recorded
REPAIR SOFT PATCH ON MAIN FIRE PUMP SUCTION. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001 No resolution recorded
REPAIR LEAK IN #1 PISTON BILGE PUMP. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Electrical
Issued 29 January 2001 No resolution recorded
REPLACE CRACKED LIGHT COVER IN UPPER ENGINE ROOM LIGHT SHINES DOWN ON CYLINDER BLOCK. SOLAS 60 II/27
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001 No resolution recorded
#2 SALTWATER COOLING PUMP FOR MAIN ENGINE HAS CEMENT PATCH ON INTAKE PIPE LOCATED AT BASE OF PUMP. PATCH IS SPLIT AND LEAKING EXCESSIVELY, YET, NOT FOUND TO BE A DIRECT HAZARD TO OPERATION OF MAIN ENGINE. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001 No resolution recorded
SALTWATER COOLING LINES EXCESSIVELY CORRODED, SOME HAVE JUBILEE PATCHES. SOLAS 60 I/11
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001 No resolution recorded
ALL FIRE FIGHTING NOZZLES IN ENGINE ROOM ARE STRAIGHT STREAM AND NEED TO BEREPLACED WITH MULTI-PURPOSE NOZZLES. SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 29 January 2001 Resolved
FIRE EXTINGUSHER MISSING FROM STATION #17. SOLAS 74 (AMENDED) II-2
Condition: Unknown
Due 1 March 2001
Resolved 31 January 2001
Navigation
Issued 29 January 2001 No resolution recorded
PERMANENTLY REPAIR ECHO DEPTH SOUNDING DEVICE TO SATISFACTION OF ATTENDING CLASS SOCIETY SURVEYOR. TO BE COMPLETED NO LATER THAN MARCH 2002 IN DRYDOCKTEMPORARY ECHO DEPTH SOUNDING DEVICE TO REMAIN OPERATIONAL IN U.S. WATERS.33CFR 164.35(i)
Condition: Unknown
Due 1 March 2002 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001 No resolution recorded
REPAIR AS ORIGINAL CEMENT PATCH IN WAY OF DECK IN REAR OF CO2 ROOM. ILLC 66ANNEX I/1
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 29 January 2001 No resolution recorded
REPAIR AS ORIGINAL EXCESSIVE WASTAGE ON STARBOARD GUNWALES. ILLC 66 ANNEX I/15
Condition: Unknown
Due 1 March 2001 — due date passed with no resolution recorded
Engineering
Issued 29 January 2001 No resolution recorded
REPAIR AS ORIGINAL REMOTE FUEL SHUTOFF TO EMERGENCY GENERATOR. SOLAS 60 II/69
Condition: Unknown
Due 12 February 2001 — due date passed with no resolution recorded
Navigation
Issued 13 July 2000 Resolved
MISSING BLOCK DIAGRAM IN STEERING CONTROL ROOM.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Lifesaving
Issued 13 July 2000 Resolved
MISSING RETRO-REFLECTIVE TAPE ON RING BOUYS FOR PORT AND STBD.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Documentation
Issued 13 July 2000 Resolved
SAFETY EQUIPMENT CERTIFICATE EXPIRED.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 13 July 2000 Resolved
REMOVE FLAMMABLES IN ENGINE ROOM TO FLAMMABLE LOCKER.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 13 July 2000 Resolved
VENT CLOSURES RUSTED.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Fire Fighting
Issued 13 July 2000 Resolved
SEMI-PORTABLE FIE EXTINGUSHERS IN ENGINE ROOM EXPIRED.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Navigation
Issued 13 July 2000 Resolved
MISSING COMMUNICATIONSFROM STEERING CONTROL ROOM TO BRIDGE.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Construction/Loadline
Issued 13 July 2000 Resolved
DOORS NOT WATERTIGHT. PROVIDE CLASS SOCIETY REPORT TO THIS COTP PRIOR TO DEPARTURE.
Condition: Unknown
Due 13 July 2000
Resolved 27 July 2000
Fire Fighting
Issued 12 August 1998 Resolved
Ship's service fire pump has a leaking valve on the pump's supply side._x001C_
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 12 August 1998 Resolved
Ship's deck on the port side of fantail, over the steering space, is in wasted condition.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Lifesaving
Issued 12 August 1998 Resolved
Excess oil located in emergency generator space, steering space, and engineroom.
Condition: Unknown
Due 7 October 1998
Resolved 7 October 1998
Documentation
Issued 9 February 1998 Resolved
NO CARGO SECURING MANUAL AVAILABLE. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 9 February 1998 Resolved
EMERGENCY GENERATOR WOULD NOT START THE REQUIRED THREE TIMES.
Condition: Unknown
Due 10 February 1998
Resolved 10 February 1998
Engineering
Issued 9 February 1998 Resolved
NO FLAME SCREENS PRESENT IN FUEL OIL VENTS. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 9 February 1998 Resolved
S/S GENERATOR LUBE OIL COOLING LINE HAS TEMPORARY REPAIRS. PROVIDE CLASS ATTESTATION AS TO CONDITION PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Engineering
Issued 9 February 1998 Resolved
MAIN ENGINE SALTWATER COOLING LINE HAS MULTIPLE REPAIRS. PROVIDE CLASS ATTESTAION AS TO CONDITION PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 April 1998
Resolved 11 April 1998
Lifesaving
Issued 9 February 1998 Resolved
NUMEROUS MEDICAL SUPLIES OUTDATED. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 13 February 1998
Resolved 13 February 1998
Lifesaving
Issued 8 August 1996 Resolved
PROVIDE OPERABLE WATERLIGHT P/S BRIDGE WING PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 8 August 1996 Resolved
REPAIR/REPLACE PORT SIDE LIFEBOAT GRABRAIL PRIOR TO DEPARTURE PORT OF MOREHEAD CITY, NC._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
PROVIDE WRITTEN CLASS ATTESTATION AS TO GENERAL CONDITION OF FIRE MAIN PIPING THROUGHOUT VESSEL PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Construction/Loadline
Issued 8 August 1996 Resolved
REPAIR/REPLACE WATER TIGHT DOOR MAIN DECK FWD OF HOUSE PRIOR TO RETURN TO NEXT U.S. PORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
REPAIR/REPLACE FIREMAIN PIPING MAIN DECK AT FOSCLE AND AT PORT SIDE AND STARBOARD SIDE AHEAD OF HOUSE PROVIDE WRITTEN CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
INSURE FIREHOSES ARE IN APPROPRIATE PLACES ACCORDING TO FIRE PLAN PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Fire Fighting
Issued 8 August 1996 Resolved
VALVE (FIRE PROTECTION) TO PAINT LOCKER SYSTIM NOT OPERATIONAL, REPAIR/REPLACE AND PROVIDE WRITTEN CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 8 August 1996 Resolved
REPAIR/REPLACE FWD LIMIT SWITCH ON P/S LIFEBOAT DAVIT AND PROVIDE CLASS ATTESTATION PRIOR TO DEPARTURE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1996
Resolved 19 August 1996
Lifesaving
Issued 26 February 1996 Resolved
Vessel to provide a quick release arrangement for the bridgewing lifebuoys as required by Solas chapter 3, Regulation 7. Compliance date of 15 APR 96 issued.
Condition: Unknown
Due 21 April 1996
Resolved 21 April 1996
Documentation
Issued 26 February 1996 Resolved
Vessel personnel could not provide a oil record book with proper entries recording the incineration of bilge slops. Vessel's O.R.B. indicated bilgespumped to slop tank, no reference to draining slop tank. Vessel given compliance date of 15 APR 96 to establish a history of proper log entries.
Condition: Unknown
Due 21 April 1996
Resolved 21 April 1996
Engineering
Issued 29 June 1995 Resolved
VSL TO PROVIDE FLAME SCREENS FOR FUEL OIL VENTS ON DECK.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Navigation
Issued 29 June 1995 Resolved
VSL HAS NO LARGE SCALE CHART FOR AREA TRANSITTED.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Documentation
Issued 29 June 1995 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE TRANSFER PROCEDURES IN CREW'S_x001C_ NATIVE LANGUAGE. (E.G. RUSSIAN)_x001C_
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Accommodation/Occupational Safety
Issued 29 June 1995 Resolved
PROVIDE CLASS/FLAG STATE APPROVAL OF MSD PRIOR TO RETURN NEXT U.S. VOYAGE.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Engineering
Issued 29 June 1995 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, PROVIDE CLASS SOCIETY ATTESTATION OF_x001C_ TEMP REPAIR (CEMENT BOX PATCH) TO M/E FRESHWATER COOLING LINE DISCHARGE.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Fire Fighting
Issued 29 June 1995 Resolved
PRIOR TO RETURN NEXT U.S. VOYAGE, INSTALL PRESS GUARGE TO #2 FIRE PUMP.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Fire Fighting
Issued 29 June 1995 Resolved
BEFORE SAILING FOREIGN A RECENT SERVICE REPORT (WITHIN 2 YEARS) OF VSL'S_x001C_ FIXED/PORTABLE F/F SYSTEMS.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Documentation
Issued 14 March 1993 Resolved
The Atlantic Clipper, a vessel with a capacity of greater than 250 barrels of il, failed to have complete oil transfer procedures in that the piping diagram was not posted.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Documentation
Issued 2 November 1987 Resolved
33CFR155.720 THE OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS WERE INCOM- PLETE.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 2 November 1987 Resolved
33CFR164.33(A)(2)(II) NO LIGHT LIST VOLUME IV ONBOARD.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 2 November 1987 Resolved
33CFR164.33(A)(3)(II) NO TIDAL CURRENT TABLES ONBOARD.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Navigation
Issued 7 July 1986 Resolved
THE VESSEL DID NOT HAVE A COPY OF THE U.S. TIDAL CURRENT TABLES OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986
Navigation
Issued 7 July 1986 Resolved
THE VESSEL DID NOT HAVE MANUEUVERING INFORMATION FOR FULL AND HALF SPEEDS POSTED ON THE BRIDGE
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986
Navigation
Issued 7 July 1986 Resolved
THE VESSELS DID NOT HAVE OPERATING INSTRUCTIONS AND SIMPLE BLOCK DIAGRAM FOR EMERGENCY STEERING CHANGEOVER PROCEEDURES POSTED ON THE BRIDGE
Condition: Unknown
Due 7 July 1986
Resolved 7 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.