MAURY USCG vessel records Sign in
← All vessels

OCEAN BEAUTY

OCEAN BEAUTY is a 1976 freight ship. The Coast Guard has recorded 55 inspections since 1984, most recently in July 2007, along with 33 deficiencies and 7 operational controls.

Records from 1984 to 2007. Most recent: inspection, 19 July 2007.

Built
1976
Last inspected
19 July 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7509263 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225424
Flag
SOUTH KOREA
—
Maury page id
psix-225424

Inspections, by type

…with no type recorded41
Years with a record 24 calendar years (1984–2007)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it8239 - Convention (Subpart B), Net Ton
24741 - Dead Weight, Ton
14984 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 55

19 July 2007 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2991936
4 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2850084
4 October 2006 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2790545
19 September 2005 Random ISPS/MTSA/PSC · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2496198
26 July 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2444238
25 July 2005 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2440405
28 April 2005 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2345231
2 November 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2230519
30 June 2004 PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2106165
18 May 2004 MTSA/ISPS Verification · Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2066953
30 December 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1980665
5 October 2003 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1914825
2 April 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1764655
20 February 2003 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1750280
1 November 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1695708
30 August 2002 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1667761
28 August 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1686635
27 February 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1490406
2 January 2002 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1722140
3 October 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294179
24 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 293090
28 August 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281436
26 July 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430950
10 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426032
18 June 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 416859
28 September 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 408318
7 December 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398098
17 October 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 396376
5 September 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394552
3 July 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 392930
26 January 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387175
2 December 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 385192
10 October 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 383600
19 August 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382100
7 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376911
10 August 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 369031
10 August 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 372270
2 June 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 358692
23 March 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 480541
5 May 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350743
30 December 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347856
1 March 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 513633
29 May 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337401
6 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 330162
28 November 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 327055
6 July 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 494611
23 November 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 319774
7 April 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 462270
29 January 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313939
18 December 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313344
25 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311558
26 March 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 444299
12 October 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 304628
1 May 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 524429
11 October 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 298492

Deficiency record · 33

Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 18 May 2004 Resolved
Repair as original the exhaust gas temperature sensors on the diesel generators. SOLAS 60 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2004
Resolution: Visually inspected new exhaust gas temperature sensors installed.
Engineering › Bilge Water Management System › Piping
Issued 18 May 2004 Resolved
Update the bilge piping diagram and/or piping arrangement to the satisfaction of the class society. SOLAS 60 I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 June 2004
Resolution: Viewed bilge piping diagram updates from Class Society.
Fire Fighting › Structural - A Class Divisions
Issued 1 November 2002 Resolved
Re-issued DF from Activity #1667761. Provide class report approving the modification to the serving window between galley and crews mess room. Also ensure modifications meet the requirements of SOLAS CH II/54. Correct to the satisfaction of attending class surveyor. LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 January 2003
Resolution: Korean Register of Shipping provided Class report stating the serving window between galley and crew mess room was closed with steel permanently and in accordance with SOLAS 60 CH II Reg. 54.
Documentation › Safety/Response Plans/Programs
Issued 24 October 2002 Resolved
Re-issued DF from Activity #1667761. See Activity #1695708 Narrative for DF details, not enough room in the deficiency details field. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 January 2003
Resolution: Korean Register of Shipping issued class report stating the modifications made to the fire boundry around the galley are now reflected on the Fire Control Plan.
Documentation › Safety/Response Plans/Programs
Issued 30 August 2002 Resolved
Update fire control plan to reflect changes/modifications made to galley doors and bulkheads. Prior to next U.S. port after sailing foreign. SOLAS 74 II-2.20 LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 1 November 2002
Resolution: Deficiency re-issued.
Fire Fighting › Structural - A Class Divisions
Issued 30 August 2002 Resolved
Make all bulkheads in galley comply w/applicable structural fire protection construction standards out lined in SOLAS. Correct prior to next U.S. port after sailing foreign. SOLAS 60 II.36 LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 1 November 2002
Resolution: Re-issued deficiency 01NOV02.
Lifesaving › Lifeboat
Issued 30 August 2002 Resolved
Provide embarkation ladders on Port and Starboard sides at life boat stations that are sufficent length to reach water in all possible conditions of vessel trim. Complete prior to next U.S. port after sailing foreign. SOLAS 60 III.19 LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 1 November 2002
Resolution: Vsl replaced both port and starboard life boat embarkation ladders with ladders that are of sufficient length to reach the water in all possible conditions of vessel trim.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 August 2002 Resolved
Vsl issued Letter of Deviation for inoperative radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2002
Resolution: Necessary repairs made. Vsl cleared to sail.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 February 2002 Resolved
Master requested a Letter of Deviation for inop radar prior to light ship Columbia River. Letter of Deviation issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2002
Resolution: Rcvd tech report verifying repair and normal operation of radar.
Documentation
Issued 24 August 2001 Resolved
Update fire control plan to reflect engine room fire fighting equipment andchanges to cargo hold CO2 system. Solas 74 AMD II-2/20 _x001C_ _x001C_ Make corrections prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 3 October 2001
Resolved 10 October 2001
Fire Fighting
Issued 24 August 2001 Resolved
Repair or renew fire fighters suit and SCBA. #2 firesuit has excessive wearon protective coating and SCBA regulator is not functioning properly. SOLAS 60 II/63_x001C_ Make corrections prior to next U.S. Port after sailing foreign.
Condition: Unknown
Due 3 October 2001
Resolved 10 October 2001
Documentation
Issued 28 August 2000 Resolved
Update IOPP certificate where manual stopping device block is marked. MARPOL 73/78 annex I._x001C_ Correct prior to next US port after sailing foreign.
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Fire Fighting
Issued 28 August 2000 Resolved
Fabricate and install handles to activate the CO2 hose reel system located near the incinerator. SOLAS 74amd II-2/21._x001C_ _x001C_ Corrected on the spot.
Condition: Unknown
Due 28 August 2000
Resolved 31 August 2000
Electrical
Issued 18 June 1998 Resolved
Repair cabinet latch on emergency switchboard. SOLAS 60 II/27
Condition: Unknown
Due 27 February 1999
Resolved 27 February 1999
Navigation
Issued 18 June 1998 Resolved
Install switch handles to steering gear controllers both port and stbd and make indicator lights on steering gear controllers operable. SOLAS 60 II/27
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Navigation
Issued 17 October 1996 Resolved
Make permanent repairs to the defective ARPA and prove proper operation, prior to the next U.S. port call. 33 CFR 164
Condition: Unknown
Due 7 December 1996
Resolved 7 December 1996
Navigation
Issued 17 October 1996 Resolved
Make permanent repairs to the defective gyrocompass and provide technician's report of proper operation, prior to departure from port._x001C_ 33 CFR 164
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Deck/Cargo
Issued 5 September 1996 Resolved
Make permanent repairs to the hydraulic leaks at the hatch cover controls for the #3 and #5 cargo holds, prior to the next U.S. port call._x001C_ 33 CFR 151.10
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Construction/Loadline
Issued 5 September 1996 Resolved
Make permanent repairs to the defective port side overboard discharge skin valve for the MSD, prior to the next U.S port call._x001C_ Solas 60, Ch II/13
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Accommodation/Occupational Safety
Issued 5 September 1996 Resolved
Return the MSD to proper operation or provide adequate arrangements for sewage storage, prior to to departure._x001C_ 33 CFR 159.53
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Accommodation/Occupational Safety
Issued 5 September 1996 Resolved
Prove proper operation of the motor to the MSD discharge pump; make repairsas needed, prior to the vessel's departure from port._x001C_ 33 CFR 159.53
Condition: Unknown
Due 6 September 1996
Resolved 6 September 1996
Navigation
Issued 26 January 1996 Resolved
Make permanent repairs to malfunctioning gyrocompass prior to port departure._x001C_ _x001C_ 33 CFR 164
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Engineering
Issued 2 December 1995 Resolved
MAKE PERMANENT REPAIRS TO MAIN ENGINE LUBE OIL COOLER DISCHARGE LINE AT TEMP PATCH. ITEM TO BE COMPLETED AT VESSELS NEXT SCHD DRYDOCK 30JAN96. SOLAS CH II-2, REG15
Condition: Unknown
Due 26 January 1996
Resolved 26 January 1996
Navigation
Issued 10 October 1995 Resolved
Make repairs to the gyrocompass to correct the 9 degree westerly error noted.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Lifesaving
Issued 19 August 1995 Resolved
Prove proper operation of starboard lifebaot engine prior to departure fromport._x001C_ _x001C_ SOLAS CH III, REG 41 (6.3)_x001C_
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 19 August 1995 Resolved
Install guard on main engine jacking gear prior to next U.S. port call._x001C_ _x001C_ _x001C_ SOLAS CH II-1, REG 26 (1)
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Fire Fighting
Issued 19 August 1995 Resolved
Make permanenet repairs to fire main coupling located at #3 cargo hold (minor leakage) prior to next U.S. port call._x001C_ _x001C_ SOLAS CH II-2, REG 2_x001C_
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Accommodation/Occupational Safety
Issued 19 August 1995 Resolved
MAKE REPAIRS TO WEATHER TIGHT DOORS 01 DECK AFT SUPERSTRUCTURE AND RENEW DOG HATCH TO EMERGENCY FIRE PUMP COMPARTMENT PRIOR TO DEPARTURE FROM PORT._x001C__x001C_ SOLAS CH II-1, REG 18_x001C_
Condition: Unknown
Due 25 August 1995
Resolved 25 August 1995
Engineering
Issued 19 August 1995 Resolved
Make permanent repairs to #1 main air compressor head casing (inter cooler)prior to next U.S. port call._x001C_ _x001C_ SOLAS CH II-2, REG 15
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Engineering
Issued 19 August 1995 Resolved
Make permanent repairs to main engine lube oil cooler discharge line (pin hole leaks and patches) prior to next U. S. port call._x001C_ _x001C_ SOLAS CH II-2, REG 15_x001C_
Condition: Unknown
Due 5 December 1995
Resolved 5 December 1995
Navigation
Issued 18 December 1986 Resolved
VESSEL'S LORAN-C RECEIVER DOES NOT HAVE THE REQUIRED LABEL ATTACHED.
Condition: Unknown
Due 18 December 1986
Resolved 18 December 1986
Navigation
Issued 25 September 1986 Resolved
VESSEL FAILED TO HAVE POSTED ON THE NAVIGATING BRIDGE A SIMPLE BLOCK DIAGRAM AND INSTRUCTIONS FOR THE STEERING GEAR.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Navigation
Issued 25 September 1986 Resolved
VESSEL FAILED TO NOTIFY THE COTP OF AN INOPERABLE LORAN-C PROIR TO ENTERING U.S. WATERS.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.