← All vessels
PANAMAX LEADER
PANAMAX LEADER is a 1976 freight ship. The Coast Guard has recorded 11 inspections since 1985, most recently in August 1998, along with 46 deficiencies and 2 operational controls.
Records from 1985 to 1998. Most recent: inspection, 27 August 1998.
- Built
- 1976
- Last inspected
- 27 August 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 46 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7509902 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HRK5
225440
Flag
LIBERIA
—
Maury page id
psix-225440
Inspections, by type
…with no type recorded11
Years with a record
9 calendar years (1985–1998)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it19853 - Regulatory (Subpart C or D), Net Ton
61804 - Dead Weight, Ton
34393 - Regulatory (Subpart C or D), Gross Ton
61804 - Dead Weight, Ton
34393 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
27 August 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 419786
9 August 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 393687
4 March 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 376275
8 October 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 353606
17 July 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 508017
16 January 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 341441
10 January 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 327847
5 July 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 324316
2 June 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 308839
28 October 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 534775
2 April 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 301148
Deficiency record · 46
Fire Fighting
Issued 9 August 1996
Resolved
Prominetly mark fire control plan weathertight enclosures._x001C_ See SOLAS 74 (Amended) II-2/20.2
Lifesaving
Issued 9 August 1996
Resolved
Conduct a satisfactory fire drill._x001C_ See SOLAS 74 (Amended) III/18.3
Fire Fighting
Issued 9 August 1996
Resolved
Provide batteries for fire lamp for upper deck fire suit storage station._x001C_ See SOLAS 60 II/63(a)
Lifesaving
Issued 9 August 1996
Resolved
Repair and prove proper operation of port lifeboat davits._x001C_ See SOLAS 74 (Amended) III/19.2
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew/repair the deteriorated/holed sewage treatment tank._x001C_ See SOLAS 74 (Amended) I/11(a)
Lifesaving
Issued 9 August 1996
Resolved
Make permenant repairs to both lifeboats or renew deteriorated lifeboats and re-install onboard vessel._x001C_ See SOLAS 74 (Amended) III/19.2
Lifesaving
Issued 9 August 1996
Resolved
Provide one additional hatchet for both lifeboats._x001C_ See SOLAS 60 III/11(a)(IV)
Engineering
Issued 9 August 1996
Resolved
Renew as original the sea water cooling pipe servicing the generators. Pipeis located on the port side lower level of the engine room outboard of the turning gear control pannel._x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original the deterioreted sewage overboard piping located on the port side lower level of the engine room outboard of the turning gear control pannel. A cement box is currently installed as a temporary repair._x001C_See SOLAS 74 (Amended) I/11(a)
Fire Fighting
Issued 9 August 1996
Resolved
Repair defective/leaking valve stem on the fire hydrant located on the starboard side forward of the #1 hold._x001C_ See SOLAS 74 (Amended) II-2/21
Deck/Cargo
Issued 9 August 1996
Resolved
Renew as original deteriorated service air piping located on the starboard side between #1 and #3 holds._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Repair/renew the deteriorated exaust piping for the emergency diesel fire pump.
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated fuel tank overflow pipe located aft of the #6 hold on the center line of the main deck._x001C_ See SOLAS 74 (Amended) I/11(a)
Fire Fighting
Issued 9 August 1996
Resolved
Repair/renew deteriorated ventilation closure located on the aft bridge deck._x001C_ See SOLAS 60 II/47(a)
Fire Fighting
Issued 9 August 1996
Resolved
Renew all defective fire hoses throughout vessel. Noted over 90% of those checked were holed. All fire hoses throughout the vessel shall be renewed and/or pressure tested in the presence of the attending U.S. Coast Guard Marine Inspector. SOLAS 74 (Amended) II-2/21
Fire Fighting
Issued 9 August 1996
Resolved
Repair defective /leaking fire hydrant located on the starboard 03 deck aft._x001C_ See SOLAS 74 (Amended) II-2/21
Construction/Loadline
Issued 9 August 1996
Resolved
Install closure dog for provision hatch located on the starboard side of the 02 deck._x001C_ See SOLAS 60 II/17
Construction/Loadline
Issued 9 August 1996
Resolved
Repair/renew the deteriorated water tight hatch on the aft center line poopdeck._x001C_ See SOLAS 60 II/17
Fire Fighting
Issued 9 August 1996
Resolved
Repair/renew inoperable closure located on starboard bridge wing._x001C_ See SOLAS 60 II/47(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated/fractured sea water supply piping for the air conditioning system located on the port side lower level of the engine room outboard of the air conditioning cooling pump._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated sea water cooling pipe servicing the main engine located on the starboard side outboard of the jacket water cooling pump._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated sea water cooling pipe for the main engine located on the on the starboard side lower level of the engine room outboard of the jacket water cooling pump. _x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original the deteriorated sewage overboard piping located on the starboard side lower level of the engine room outboard of the #1 fuel oil purifier. A cement box is presently installed._x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original the deteriorated sea water supply pipe for the sewage system located on the #2 deck of the engine room the starboard side outboard of #1 generator._x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original the deteriorated fresh water supply pipe to the hot watertank located on the port side upper level of the engine room._x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original the deteriorated piping for the sewage treatment tank located above and in immediate viscinity of the treatment tank on the upperlevel of the engine room._x001C_ See SOLAS 74 (Amended) I/11(a)
Accommodation/Occupational Safety
Issued 9 August 1996
Resolved
Renew as original all deteriorated sewage piping located above the engine room control room on the port side upper level ofthe engine room._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated sea water discharge piping from the auxiliary fresh water cooler located on the #2 deck of the engine room on the starboard side outboard of the #1 generator._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original the deteriorated/leaking fitting on the sea water supply piping for the lube oil cooler located on the starboard side out board of the main engine._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 9 August 1996
Resolved
Renew as original deteriorated piping for the main condenser sea water system servicing the boiler located above lube oil and main fresh water coolers on the #2 deck starboard side of the engine room._x001C_ See SOLAS 74 (Amended) I/11(a)
Fire Fighting
Issued 9 August 1996
Resolved
Renew missing fire hydrant for station located on the starboard side of theengine room on the #2 level outboard of the main engine._x001C_ See SOLAS 74 (Amended) I/11(a)
Engineering
Issued 4 March 1995
Resolved
OILY WATER SEPARATER INOPERABLE.
Fire Fighting
Issued 4 March 1995
Resolved
FIRE HYDRANT ON FOCSLE INOPERABLE.
Lifesaving
Issued 4 March 1995
Resolved
STRUCTURAL INTEGRITY OF LIFEBOAT NOT SEAWORTHY.
Fire Fighting
Issued 4 March 1995
Resolved
CO2 ROOM CYLINDERS NOT INSPECTED.
Fire Fighting
Issued 4 March 1995
Resolved
EMERGENCY FIREPUMP INOPERABLE.
Documentation
Issued 4 March 1995
Resolved
OIL TRANSFER PROCEDURES NOT ONBOARD.
Fire Fighting
Issued 4 March 1995
Resolved
FIRE CONTROL PLAN NOT UPDATED.
Lifesaving
Issued 4 March 1995
Resolved
FIREMAN'S SUIT MISSING FLASHLIGHT AND AX.
Lifesaving
Issued 4 March 1995
Resolved
SURVIVAL MANUAL MISSING FROM STARBOARD LIFEBOAT.
Fire Fighting
Issued 4 March 1995
Resolved
ADJUSTABLE NOZZLES MISSING FROM INSIDE FIRESTATIONS.
Lifesaving
Issued 4 March 1995
Resolved
NOT ALL LIFEBUOYS SEAWORTHY.
Electrical
Issued 4 March 1995
Resolved
STANDBY GENERATOR INOPERABLE.
Documentation
Issued 10 January 1989
Resolved
VESSEL DID NOT HAVE A CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO ENTRY INTO HONOLULU ANCHORAGE, A NAVIGABLE WATERWAY OF THE UNITED STATES. THE VESSEL WAS DETAINED FROM BUNKERING OPS UNTIL A CONFIRMED APPLICATION FOR A CFR WAS REQUESTED BY HONMS.
Navigation
Issued 5 July 1988
Resolved
THE VESSEL'S CHARTS OF THE AREA WERE NOT CURRENTLY CORRECTED.
Navigation
Issued 5 July 1988
Resolved
THE VESSEL'S TIDE TABLES WERE OUTDATED (87) AND WERE NOTE CURRENTLY CORRECTED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.