Records from 1984 to 2005. Most recent: operational control imposed, 8 August 2005.
Inspection history · 55
8 August 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2456385
19 May 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2369812
6 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2328811
4 April 2005
MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2326144
3 July 2004
NPV Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2118992
15 May 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2068376
12 June 2003
Type not recorded
No type recorded · USCGC VIGOROUS (WMEC 627) · Activity 1822365
28 April 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1782243
16 January 2003
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1731359
15 October 2002
Re-Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1689870
3 July 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1640593
27 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1643603
15 May 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616917
15 May 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1616977
1 April 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599594
29 March 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1598990
8 September 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 420092
20 May 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 670686
12 May 1998
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 415823
10 June 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 404523
21 May 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 403796
3 April 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 402336
22 May 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 391390
21 May 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 378541
21 November 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372540
23 September 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 41836
19 May 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 366947
9 March 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 365134
6 November 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 651391
5 November 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 452016
31 October 1993
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 121368
14 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 651390
9 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 31435
9 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 354936
6 October 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 451389
1 April 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 349777
15 October 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 509135
23 April 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 343319
10 January 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 483561
14 June 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 455685
5 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 336285
15 September 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 469076
31 March 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 329422
13 December 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 438686
17 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323355
12 April 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 322581
15 December 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 457946
14 April 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 315430
25 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 507053
27 April 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 308444
16 December 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 305933
6 August 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 540581
3 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 441284
19 October 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 298481
16 July 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 297161
Documentation › Certificates/Documents
Issued 16 January 2003
Resolved
VESSEL INSPEDTED IN BALTIMORE 15OCT02 WITH 9 DEFICIENCIES ISSUED ACTIVITY #1609870. CLASS TO ATTEST TO REPAIR BY 15NOV02. VESSEL ARRIVED BALTIMORE 16JAN03 WITH ALL ITEMS STILL OUTSTANDING. CLASS TO ATTEST TO ABOVE DEFICIENCIES PRIOR TO DEPARTURE PORT OF BALTIMORE.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 January 2003
Resolved 16 January 2003
Resolution: RECEIVED CLASS REPORT ATTESTING TO THE DEFICIENCIES.
Lifesaving › Launching Appliances
Issued 15 October 2002
Resolved
REPAIR WASTED CHECK PLATE ON DAVIT SYSTEM WINCH DRUM, STBD SIDE AFT. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: CHECK PLATE HAS BEEN REINFORCED.
Engineering › Compressed Air System (control)
Issued 15 October 2002
Resolved
REMOVE AIR HOSE FROM BOSN STORE ROOM FWD AND REPLACE WITH PIPE. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: HOSE HAS BEEN REPLACED WITH PIPE.
Deck/Cargo › Holds/Tanks
Issued 15 October 2002
Resolved
NUMEROUS STANCHIONS AND BRACKETS ASSOCIATED WITH HATCH COAMINGS FOUND WASTED AND FRACTURED, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Coaming
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: CLASS HAS ATTESTED TO THE PROPER REPAIR OF WASTED METAL.
Fire Fighting › Fire Main
Issued 15 October 2002
Resolved
CLASS TO ATTEST TO PROPER REPAIR OF FIRE MAIN SYSTEM. DOUBLERS FOUND AT VARIOUS LOCATIONS ALONG CARGO BLOCK. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: WASTED SECTION HAS BEEN REPLACED.
Construction/Loadline › Penetrations
Issued 15 October 2002
Resolved
DECK SCUPPER OVBD PIPE HAS CEMENT PATCH IN STEERING GEAR ROOM, REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: PIPE HAS BEEN REPLACED.
Pollution Prevention/Response › Prevention Equipment
Issued 15 October 2002
Resolved
SOFT PATCH FOUND ON DISCHARGE PIPE FOR OWS INBOARD OF OVBD VALVE. MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: WASTED SECTION HAS BEEN REPLACED.
Accommodation/Occupational Safety › Potable Water System
Issued 15 October 2002
Resolved
SOFT PATCH AND DOUBLER FOUND ON FRESH WATER GENERATOR. MAKE REPAIRS TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: WASTED PIPE HAS BEEN REPLACED.
Engineering › Diesel Engine (auxiliary)
Issued 15 October 2002
Resolved
STBD SIDE SSDG SALT WATER COOLING PUMP LEAKS AT FLANGE. MAKE REPAIRS TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: GASKET HAS BEEN REPLACED.
Engineering › Compressed Air System (control)
Issued 15 October 2002
Resolved
MAIN CONDENSOR LEAKS ON DISCHARGE PIPE. MAKE REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 16 January 2003
Resolution: PIPE HAS BEEN REPLACED.
Fire Fighting › Fixed Fire Detection System
Issued 1 April 2002
Resolved
Replace smoke detector above fuel oil filter (heater) adjacent to main switchboard. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 April 2002
Resolved 14 May 2002
Resolution: SMOKE DETECTOR REPLACED AND APPEARED TO BE SATISFACTORY.
Engineering › Generator (propulsion-electric)
Issued 1 April 2002
Resolved
Gasket on diesel oil filter of generator #2 causing minor leaking. Gasket needs to be replaced.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 28 April 2002
Resolved 14 May 2002
Resolution: GASKET AND OIL FILTER UNIT WAS REPLACED. ITEM APPEARED TO BE IN NEW CONDITION. ITEM SATISFACTORY TO THE ATTENDING INSPECTOR.
Engineering › Lubricating Oil Service System
Issued 1 April 2002
Resolved
Section of insulation worn, missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 14 May 2002
Resolution: INSULATION WAS REPLACED AND OBSERVED IN EXCELLENT CONDITION. ITEM SATISFACTORY TO THE ATTENDING INSPECTOR.
Fire Fighting
Issued 12 May 1998
Resolved
Insulation/lagging around exhaust for emergency fire pump not flame retardent - during test of fire pump engine the exhaust caused the lagging to heat so much it almost caught fire - new flame retardent lagging put in place - engine ran to temp and no further problems noted.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Fire Fighting
Issued 12 May 1998
Resolved
Vsl's fire control plans need updated to denote firemans outfit box IWO _x001C_ the CO2 room.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Deck/Cargo
Issued 12 May 1998
Resolved
Pesticide, Liquid, toxic, N.O.S., 6.1, UN2902 container #TRIU4414573 did_x001C_ not have the required Marine pollutant marks.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Deck/Cargo
Issued 12 May 1998
Resolved
Wrote requirement for container IEAU4113312 to be inspected upon discharge in New Orleans. Container has some noted damage & splicing on doors. CSC plate id number does not match container id number. Cargo is UN1474, Magnesium Nitrate.
Condition: Unknown
Due 15 May 1998
Resolved 20 May 1998
Navigation
Issued 12 May 1998
Resolved
Vessel's echo depth sounding device/recorder not operating properly.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Electrical
Issued 12 May 1998
Resolved
#1 s/s generator f/o hose was being drained directly into bilge.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Electrical
Issued 12 May 1998
Resolved
Both s/s generators leaking f/o. Excessive amount of this fuel not being drained properly & leakihg down engines into the bilges.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Engineering
Issued 12 May 1998
Resolved
In forward stbd side of e/r - overhead of l/l. Steam leak noted from flange. Requirement written to have corrected prior to returning from_x001C_ next overseas voyage.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Accommodation/Occupational Safety
Issued 21 May 1997
Resolved
WEATHERTIGHT DOOR DRYROTTED ON CAPTAIN'S BRIDGE DECK LEVEL._x001C_ ILO 147
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Lifesaving
Issued 21 May 1997
Resolved
BOTH LIFEBOAT SYSTEMS (PNEUMATIC) REPLACED WITH ELECTRICAL SYSTEMS. LIMIT SWITCHES NOT YET CONNECTED. CORRECT PRIOR TO NEXT U.S. VOYAGE. VESSEL'S_x001C_ CLASS TO ATTEST TO REPAIRS MADE. SOLAS 74 III/19.2
Condition: Unknown
Due 10 June 1997
Resolved 10 June 1997
Engineering
Issued 22 May 1996
Resolved
Make permanent repairs/replace main sea water line suction "strainer body" of NO. 2 main sea water cooling pump. (Is presently wasted and temporarilypatched with cement.) Make repairs to the satisfaction of the Classification Society. SOLAS 74 AMENDED I/11
Condition: Unknown
Due 5 April 1997
Resolved 5 April 1997
Fire Fighting
Issued 22 May 1996
Resolved
Remove blank in bilge/ballast water pump piping going to main fire pump line (This is a designated fire pump) thus allowing flow to firemain line._x001C__x001C_ SOLAS 60 II/56
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Documentation
Issued 12 April 1988
Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE DATE IT WAS PREPARED AS REQUIRED BY 49 CFR 176.30(B).
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Navigation
Issued 12 April 1988
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH U. S. COAST PILOT NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33 (A)(2)(I) OR AN EQUIVALENT FOREIGN GOVERNMENT PUBLICATION IAW 33 CFR 164.33 (B).
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Documentation
Issued 12 April 1988
Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE PROPER SHIPPING NAME AS REQUIRED BY 49 CFR 176.30(A)(3).
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Navigation
Issued 16 December 1985
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE STEERING GEAR OPERATING AND CHANGEOVER INSTRUCTIONS AND DIAGRAM REQ BY 33 CFR 164.35 (K) WERE NOT POSTED ON THE BRIDGE.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Deck/Cargo
Issued 16 December 1985
Resolved
A VIO OF 49 CFR 172.102 (TABLE) IN THAT 6 DRUMS OF HYDROBROMIC ACID, SOLUTION (UN 1788) WAS STOWED UNDER DECK. THE STOWAGE FOR THIS CARGO IS ON DECK ONLY.
Condition: Unknown
Due 16 December 1985
Resolved 16 December 1985
Navigation
Issued 16 July 1984
Resolved
3 CM. RADAR FOUND TO BE INOPERATIVE PRIOR TO VESSEL DEPARTURE. COPT ISSUED A LETTER OF DEVIATION DUE TO DEPARTURE TIME OF THE VSL.
Condition: Unknown
Due 20 August 1984
Resolved 16 July 1984