Records from 1984 to 2002. Most recent: inspection, 28 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
28 January 2002
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1478719
19 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 407003
29 January 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 387197
9 January 1995
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 374009
23 September 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 371117
15 February 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 364533
31 August 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 360556
22 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 174469
19 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 160550
12 June 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 358840
15 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 356840
24 December 1992
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 355296
10 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 354906
17 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352627
27 January 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348334
17 September 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 345911
28 September 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 524057
2 May 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 518611
27 November 1989
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 333931
26 June 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 511617
27 December 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 327546
11 July 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 527637
27 December 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 320315
12 December 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 313221
6 January 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 306173
10 December 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 299357
Engineering › Bilge Water Management System
Issued 28 January 2002
Resolved
BA10 - REPAIR SOFT PATCH WITH PERMANENT REPAIRS TO SALT WATER BILGE WATER RETURN PIPE TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 31 January 2002
Resolution: CLASS REPORT
Navigation › Piloting/Steering
Issued 28 January 2002
Resolved
BA01 - VESSEL IS MISSING SAILING DIRECTIONS (ASD 68 & 69) PUBLICATIONS. FAX RECEIPT TO USCG ACTIVITIES BALTIMORE. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 28 January 2002
Resolved 29 January 2002
Resolution: RECEIVED RECEIPT VIA FAX.
Engineering
Issued 28 January 2002
Resolved
BA11 - REPAIR #2 DECK CONTAINMENT (WASTED) TO THE SATISFACTION OF USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS SOCIETY.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 January 2002
Resolved
BA09 - PROVIDE 6 PC. OF FOOD RATIONS (10,000 KJ) (1-PORT, 5-STBD)
Condition: Unknown
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat
Issued 28 January 2002
Resolved
BA02 - PORT LIFEBOAT-RUDDER ARM MOUNT WASTED. REPAIR TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Rudder/Tiller/Steering
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 28 January 2002
Resolved
BA03 - PORT LIFEBOAT-RUBRAIL WITH LIFELINES IS ROTTED. REPLACE TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat
Issued 28 January 2002
Resolved
BA04 - PORT LIFEBOAT - SAIL MOUNT IS FROZEN. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat
Issued 28 January 2002
Resolved
BA05 - PORT LIFEBOAT - BRAKE WILL NOT OPERATE WHEN RELEASED. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat
Issued 28 January 2002
No resolution recorded
BA06 - PORT LIFEBOAT-SAFETY LIMIT SWITCH WILL NOT OPERATE. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002 — due date passed with no resolution recorded
Resolution: CLEARED BY CLASS.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 28 January 2002
Resolved
BA07 - PORT LIFEBOAT-PROVE PROPER OPERATION OF ROTTERMER GEAR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Lifesaving › Launching Appliances › Winch
Issued 28 January 2002
Resolved
BA08 - PORT LIFEBOAT-AFT WINCH DRUM INBOARD CHEEK PLATE WASTED. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 31 January 2002
Resolution: CLEARED BY CLASS.
Deck/Cargo
Issued 23 September 1994
Resolved
Vessel had no containment around lube oil and cylinder oil fill pipe.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Documentation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 AND FURTHER DESCRIBED BY REFERENCE TO 33 CFR 155.310 WERE INCOMPLETE IN THAT THEY DID NOT CONTAIN DUTIES BY TITLE OF EACH OFFICER, PERSON IN CHARGE, TANKERMAN, DECKHAND, ETC.,REQ FOR EACH OIL TRANSFER OPERATION.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Documentation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 155.450 IN THAT THE VSL DID NOT HAVE ONBOARD A DISCHARGE OFOIL PROHIBITED PLACARD POSTED IN EITHER EACH MACHINERY SPACE OR AT THE BILGE AND BALLAST CONTROL STATION.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Navigation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST, OLD VOL I USED BY THE VSL, WAS NOT CURRENTLY CORRECTED TO NTM 32/86 WHICH WAS REASONABLY AVAIL- ABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO ELIZABETH RIVER TERMINALS, NORFOLK,VA. NO FOREIGN EQUIV ONBOARD.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Navigation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT, VOL 3, USED BY THE VSLWAS NOT CORRECTED TO NTM 19/86, WHICH WAS REASONABLY AVAILABLE AND CON- TAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO ELIZABETHRIVER TERMINALS, NORFOLK, VA. NO FOREIGN EQUIV ONBOARD.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Navigation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES, OR ITS FOREIGN EQUIV, AS REQ BY 33 CFR 164.33(A)(3)(II) WERE NOT ONBOARD. THE VSL DID NOT HAVE ANY U.S. TIDAL CURRENT TABLES OR ITS FOREIGN EQUIV ONBOARD. THE MOST CURRENT ED IS DATED 1987.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986
Navigation
Issued 12 December 1986
Resolved
A VIO OF 33 CFR 164.11(Q) IN THAT THE TESTS REQ BY 33 CFR 164.25(A) WERE CONDUCTED BUT NOT RECORDED IN THE VESSEL'S LOG.
Condition: Unknown
Due 12 December 1986
Resolved 12 December 1986