MAURY USCG vessel records Sign in
← All vessels

REDUTA ORDONA

REDUTA ORDONA is a 1978 freight ship. The Coast Guard has recorded 21 inspections since 1986, most recently in April 2003, along with 15 deficiencies.

Records from 1986 to 2003. Most recent: inspection, 21 April 2003.

Built
1978
Last inspected
21 April 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7515004 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225485
Flag
POLAND
—
Maury page id
psix-225485

Inspections, by type

…with no type recorded19
Years with a record 15 calendar years (1986–2003)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it12188 - Convention (Subpart B), Net Ton
12188 - Simplified, Net Ton
33490 - Dead Weight, Ton
20357 - Convention (Subpart B), Gross Ton
20357 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

21 April 2003 MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1771444
4 April 2002 Re-Inspection · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1600948
26 September 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 294130
22 February 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287234
10 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283154
20 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 434100
11 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425524
9 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96515
20 November 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 422780
20 November 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 410266
27 November 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 397945
7 February 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 387832
11 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365890
31 March 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 357257
12 September 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 481835
2 February 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348393
27 January 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 349031
25 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343988
14 January 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 327939
23 June 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 461577
6 November 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 312518

Deficiency record · 15

Pollution Prevention/Response › Prevention Equipment
Issued 21 April 2003 Resolved
Replace all oily water filters, and clean all oily water sensors. make sure all discharge (overboard) pipes are clean. Prove proper operation of OWS LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2003
Resolution: Installed new Oily Water Seperator and operated to Classification Society and USCG satisfaction.
Fire Fighting › Fire Pumps › Suction Valve
Issued 21 April 2003 Resolved
Prove working condition of the emergency fire pump.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 25 April 2003
Resolution: Classification society representative attested to the proper operation of the fire pump due to the suction being above the water line.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 21 April 2003 Resolved
Cannot provide sufficient proof of maintenamce of the Oily Water Separator. Perform external ISM audit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2003
Resolution: Classification society representative performed satisfactory external ISM Audit with 4 non-conformities identified.
Construction/Loadline › Markings › Load Line Mark
Issued 21 April 2003 Resolved
Loadline mark not of contrasting color/ not in accordance with certificate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2003
Resolution: Witnessed proper repair and painting of load line.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 April 2003 Resolved
Portside Lifebouy self igniting light inoperable (embarcation area)
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 25 April 2003
Resolution: Master purchased new self igniting light and replaced
Lifesaving
Issued 26 September 2001 Resolved
VESSEL'S EMBARKATION LADDER FOR THE PORT LIFEBOAT IS WASTED AND NEEDS TO BEREPLACED.
Condition: Unknown
Due 26 October 2001
Resolved 16 April 2002
Resolution: [name withheld] REPAIR OF PORT LIFEBOAT EMBARKATION LADDER.
Navigation
Issued 10 October 2000 Resolved
MAKE PROPER REPAIRS TO LEAKING STEERING PUMP VENT PLUGS AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Accommodation/Occupational Safety
Issued 10 October 2000 Resolved
MAKE PROPER REPAIRS TO TEMPORARY REPAIR ON SEWAGE OVERBOARD PIPE AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Accommodation/Occupational Safety
Issued 10 October 2000 Resolved
MAKE PROPER REPAIRS TO WASTED/BROKEN GUARDRAILS PORT SIDE IWO #4 CARGO HOLDAND AT STBD BOW.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Fire Fighting
Issued 7 February 1996 Resolved
EMERGENCY FIRE PUMP WAS UNABLE TO GAIN SUCTION.
Condition: Unknown
Due 10 February 1996
Resolved 12 February 1996
Lifesaving
Issued 7 February 1996 Resolved
REPAIR OR REPLACE MANUEL BILGE PUMPS FOR BOTH LIFEBOATS. CORRECT PRIOR TO NEXT U.S. PORT OR BY 07MAR96.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Accommodation/Occupational Safety
Issued 11 April 1994 Resolved
VESSEL MSD WAS NOT LABELED WITH APPROVAL NUMBER.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Unknown
Issued 6 November 1986 Resolved
VSL OPERATING IN U.S. WATERS WITHOUT APPROVED OILY WATER SEPARATING EQUIP- MENT.
Condition: Unknown
Due 23 June 1987
Resolved 6 November 1986
Documentation
Issued 6 November 1986 Resolved
VSL OPERATING IN U.S. WATERS WITH AN EXPIRED INTERNATIONAL OIL POLLUTION PREVENTION CXERTIFICATE.
Condition: Unknown
Due 23 June 1987
Resolved 6 November 1986
Unknown
Issued 6 November 1986 Resolved
VSL MISSING THE USCG CERTIFICATION LABEL ON IT'S MSD.
Condition: Unknown
Due 6 November 1986
Resolved 6 November 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.