MAURY USCG vessel records Sign in
← All vessels

GUR MASTER

GUR MASTER is a 1978 freight ship. The Coast Guard has recorded 15 inspections since 1984, most recently in May 1997, along with 25 deficiencies.

Records from 1984 to 1997. Most recent: inspection, 29 May 1997.

Built
1978
Last inspected
29 May 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7519751 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225543
Flag
GREECE
—
Maury page id
psix-225543

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (1984–1997)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6570 - Regulatory (Subpart C or D), Net Ton
15769 - Dead Weight, Ton
10100 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

29 May 1997 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 404257
26 May 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 403998
1 April 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390044
20 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388197
2 May 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 377829
26 July 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 455927
26 July 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412679
31 March 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 365606
17 October 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 361633
28 August 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 352828
21 May 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 337221
8 August 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 502110
1 August 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 331772
25 November 1987 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 319821
30 May 1984 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 299114

Deficiency record · 25

Lifesaving
Issued 29 May 1997 Resolved
Need to have instruction for use of new life jackets. SOLAS 74, III/18.4
Condition: Unknown
Due 30 July 1997
Resolved 2 June 1997
Accommodation/Occupational Safety
Issued 29 May 1997 Resolved
Crew shower, first deck starboard side inappropriate. ILO 147
Condition: Unknown
Due 30 May 1997
Resolved 2 June 1997
Lifesaving
Issued 29 May 1997 Resolved
Life raft service inspection expired. SOLAS 73, III/19.8.1_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 October 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 29 May 1997 Resolved
Lights in engine room escape trunk burned out. SOLAS 60, Reg II
Condition: Unknown
Due 30 May 1997
Resolved 2 June 1997
Fire Fighting
Issued 29 May 1997 Resolved
Biennial test of engine room CO2 system expired. SOLAS 74, II/2
Condition: Unknown
Due 8 October 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 May 1997 Resolved
Ring Bouy quick release not working. SOLAS 74 reg 111/19.2
Condition: Unknown
Due 29 May 1997
Resolved 2 June 1997
Electrical
Issued 29 May 1997 Resolved
Excessive water leak on stbd fire pump seal. SOLAS 74 II/2
Condition: Unknown
Due 30 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 29 May 1997 Resolved
Ring Bouy light batteries were expired, SOLAS 74 REG 111/21e, 60 REG 111/21e._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 26 May 1997 Resolved
Fire hoses missing from all weather deck fire stations.
Condition: Unknown
Due 26 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 26 May 1997 Resolved
Lighting fixture in paint locker not working, taken apart.
Condition: Unknown
Due 27 May 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 1 April 1996 Resolved
A VIO OF SOLAS 74 AMENDED CH III REF. 26.3 IN THAT THE VESSEL IS REQUIRED TO PROVIDE A 6 MAN LIFERAFT AT THE BOW IN PLACE OF 10 MAN LIFERAFT. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 1 April 1996 Resolved
A VIO OF SOLAS 74 AMENDED CH II-2 REG 17.3 IN THAT THE VESSEL IS REQUIRED TO PROVIDE FUNCTIONAL BATTERIES FOR THE FIREMAN OUTFITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 April 1996
Resolved 11 April 1996
Lifesaving
Issued 1 April 1996 Resolved
A VIO OF SOLAS 74 AMENDED CH-3 REG 19.8.1 IN THAT THE VESSEL IS REQUIRED_x001C_ TO PROVIDE A NEW HYDROSTATIC RELEASE FOR THE 25 MAN LIFEBOAT.
Condition: Unknown
Due 3 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 1 April 1996 Resolved
A VIO OF SOLAS 74 AMENDED CH 11-2 REG 21 IN THAT THE VESSEL IS REQUIRED TO PROVIDE REQUIRED AMOUNT OF FIRE HOSES AND NOZZELS TO OUTFIT THE ENTIRE SHIP. NOZZELS AND HOSES MUST MATCH FITTINGS._x001C_ _x001C_
Condition: Unknown
Due 3 April 1996
Resolved 11 April 1996
Lifesaving
Issued 1 April 1996 Resolved
A VIO OF SOLAS 60 CH III REG 11 IN THAT THE VESSEL MUST REPAIR THE PORT LIFEBOAT'S MAST.
Condition: Unknown
Due 3 April 1996
Resolved 11 April 1996
Navigation
Issued 20 March 1996 Resolved
A violation of 33 cfr 164.33(a)(2)(i) in that the vessel must have on boarda currently corrected U.S. Coast Pilot or foreign equivalent. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1996
Resolved 28 March 1996
Documentation
Issued 1 August 1989 Resolved
NO CARGO INSPECTIONS MADE AND OR LOGGED FOR BULK CARGO SHIPMENT. CITE: 46 CFR 148.03-7
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Documentation
Issued 1 August 1989 Resolved
IDENTIFICATION NUMBER FOR SODIUM NITRATE WAS NOT CORRECT. CITE: 49 CFR 176.30(A)(3)
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Documentation
Issued 1 August 1989 Resolved
NO CERTIFICATION STATEMENT ON SHIPPING PAPERS. CITE: 46 CFR 148.02-1(A)(4)
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989 Resolved
1988 BRITISH ADMIRALTY LIGHT LIST VOL J HAD NO CORRECTIONS. THERE ARE SEVERAL NTM CORRECTIONS FOR THE AREA OF TRANSIT. CITE: 33 CFR 164.33(A)(2)(II)
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 1 August 1989 Resolved
NO COPY OF THE U.S. INLAND NAVIGATION RULES ONBOARD. CITE: 33 CFR 88.05
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Documentation
Issued 1 August 1989 Resolved
ITEMS NO 1, 2, AND 3 ON DCM MISSING HAZARD CLASS DESIGNATION. CITE: 49 CFR 176.30(A)(5)
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Documentation
Issued 1 August 1989 Resolved
ITEM NO 3 ON DCM MISSING WIEGHT PER PACKAGE. CITE: 49 CFR 176.30(A)(4)
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Navigation
Issued 25 November 1987 Resolved
CHARTS NOT UPDATED WITH LOCAL NOTICE TO MARINERS
Condition: Unknown
Due 25 November 1987
Resolved 25 November 1987
Documentation
Issued 30 May 1984 Resolved
VSL HAD NO VALID IOPP CERTIFICATE ON BOARD.
Condition: Unknown
Due 1 June 1984
Resolved 30 May 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.