Records from 1984 to 2004. Most recent: inspection, 13 May 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
13 May 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2253067
25 January 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 647992
23 December 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 423969
4 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412705
25 December 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 398749
24 December 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 386174
19 April 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 336614
15 February 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328320
28 January 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 321029
10 September 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311324
17 June 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 302688
18 June 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 296704
Lifesaving
Issued 23 December 1998
Resolved
VESSEL WAS MISSING LIGHTS ON THERE LIFE JACKETS ON THE BRIDGE. ADVISED MASTER THAT THEY WERE REQUIRED TO HAVE LIGHTS ON LIFE JACKETS.
Condition: Unknown
Due 24 December 1998
Resolved 24 December 1998
Documentation
Issued 23 December 1998
Resolved
VESSEL'S PRE-ARRIVAL TESTS WERE LOGGED IMPROPERLY.
Condition: Unknown
Due 24 December 1998
Resolved 24 December 1998
Documentation
Issued 23 December 1998
Resolved
VESSEL HAD NO GARBAGE RECIEPTS ONBOARD. MASTER WAS ADVISED OF THE POLICIESCONCERNING GARBAGE.
Condition: Unknown
Due 24 December 1998
Resolved 24 December 1998
Navigation
Issued 23 December 1998
Resolved
VESSEL MISSING INLAND NAVIGATION RULES. VESSEL CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 December 1998
Resolved 24 December 1998
Fire Fighting
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE SPANNER WRENCHES AT ALL HYDRANTS/HOSE STATIONS, PER SOLAS CHPT II-2 REG 4(7.1)._x001C_
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Construction/Loadline
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, REPAIR PIPING AS FOLLOWS: COOLING WATER INLET TOCONDENSER, COOLING WATER TO F/W EVAP, WASTE WATER TO GALLEY, OFFICER'S MESSDRAIN, SEWAGE DRAIN FROM TANK.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Fire Fighting
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE AUTOMATIC CLOSING DEVICE FOR FIREDOOR BETWEEN ENGINEROOM AND STEERING GEAR ROOM.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Fire Fighting
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE AUTOMATIC CLOSING DEVICE FOR FIREDOOR BETWEEN PASSAGEWAY AND STEERING GEAR ROOM PER SOLAS CHPT II-2 REG 47.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Lifesaving
Issued 24 December 1995
Resolved
PRIOR TO DEPARTURE, PROVE PROPER OPERATION OF LIFEBOAT RADIOS PER SOLAS CHPT III REG 6(2.1.1).
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Lifesaving
Issued 24 December 1995
Resolved
PRIOR TO DEPARTURE, PROVIDE LETTER FROM ADMINISTRATION EXTENDING ANNUAL SERVICING REQUIREMENT OR SERVICE LIFERAFTS PER SOLAS CHPT III REG 19(8).
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Lifesaving
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE AMEND OIL TRANSFER PROCEDURES TO INCLUDE CARGO INFORMATION REQUIRED IN 33 CFR 155.750(A)(1)(II), & 33 CFR 154.310(A)(5)(II).
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Accommodation/Occupational Safety
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, REPLACE WASTED AND LEAKING "T" PIPING AT MANIFOLD NEXT TO DISCHARGE PUMP BY COLLECTION TANK, PER ILO147.
Condition: Unknown
Due 29 December 1995
Resolved 29 December 1995
Fire Fighting
Issued 24 December 1995
Resolved
PRIOR TO NEXT U.S. VOYAGE, REPAIR/REPLACE NO. 7 FIRE HOSE STATION CABINET TO MAKE READY ACCESS PER SOLAS CHPT II-2.
Condition: Unknown
Due 29 December 1995