Records from 1987 to 1998. Most recent: inspection, 8 May 1998.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
8 May 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 415740
16 November 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384970
26 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 384278
4 October 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 383417
6 February 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 314248
Lifesaving
Issued 4 October 1995
Resolved
Repair engine cover on starboard lifeboat engine, prior to next U.S. port call after foreign voyage._x001C_ _x001C_ Solas, Ch III, Reg 41 (6.9)
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Lifesaving
Issued 4 October 1995
Resolved
Post liferaft launching instructions in location of liferafts._x001C_ _x001C_ _x001C_ Solas Ch III, Reg 9 (2)
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Engineering
Issued 4 October 1995
Resolved
Install containment around lube oil fill lines on main deck, port and starboard side, prior to the next U. S. port call after foreign voyage._x001C_ _x001C_
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Unknown
Issued 4 October 1995
Resolved
Provide class survey report on condition of hull in connection with vessel's grounding in Astoria anchorage, prior to departure from port._x001C_ _x001C_
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Fire Fighting
Issued 4 October 1995
Resolved
Make permanent repairs to leak on fire main at #3 cargo hold, starboard side, at next drydock. (A temporary doubler patch was approved by the ABS surveyor.)_x001C_ Solas Ch II-2, Reg 4 (b.i)
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Construction/Loadline
Issued 4 October 1995
Resolved
Re-install dogging nuts on all cargo hold entrance hatches, prior to departure from port._x001C_ _x001C_ ILLC Ch II, Reg 18 (1).
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Electrical
Issued 4 October 1995
Resolved
Make permanent repairs to port generator oiler pump for valve train_x001C_ _x001C_ _x001C_ Solas Ch II-1, Reg 26 (1)
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Engineering
Issued 4 October 1995
Resolved
Install metal caps on all sounding/temp tubes on main deck for fuel oil tanks prior to next U. S. port call after a foreign voyage._x001C_ _x001C_
Condition: Unknown
Due 12 May 1998
Resolved 12 May 1998
Electrical
Issued 4 October 1995
Resolved
Install valve covers on both generators (oil being spilled on exhaust manifold poses fire hazard), prior to departure from port._x001C_ _x001C_ Solas Ch II-1, Reg 26 (1)
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Engineering
Issued 4 October 1995
Resolved
Make permanent repairs to leaks on Port and Starboard generator R/W coolinglines prior to departure from port._x001C_ _x001C_ Solas Ch II-1, Reg 26 (1)
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995