KUCHULU
KUCHULU is a 1977 freight ship. The Coast Guard has recorded 26 inspections since 1988, most recently in February 2000, along with 34 deficiencies — 1 with no resolution recorded — and 3 operational controls.
Records from 1988 to 2000. Most recent: inspection, 17 February 2000.
- Built
- 1977
- Last inspected
- 17 February 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 34 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7523063 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HUG3
225578
Flag
GREECE
—
Maury page id
psix-225578
Inspections, by type
…with no type recorded25
…past their stated due date1
Years with a record
8 calendar years (1988–2000)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10739 - Regulatory (Subpart C or D), Net Ton
28634 - Dead Weight, Ton
17661 - Regulatory (Subpart C or D), Gross Ton
28634 - Dead Weight, Ton
17661 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
17 February 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 274914
9 April 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 389827
28 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384295
20 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 707894
9 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 379492
28 April 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 377918
17 April 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 377300
11 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 494345
10 April 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 499521
13 December 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 707895
9 December 1994
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 373131
9 December 1994
MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 834308
5 December 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 468419
2 December 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 372884
2 December 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 870511
30 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 707896
29 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 510779
25 November 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 373006
24 November 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372679
18 August 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 369382
4 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 475421
4 May 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1391993
19 May 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 358395
28 September 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346155
22 May 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 337264
24 February 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 321578
Deficiency record · 34
Navigation
Issued 17 February 2000
No resolution recorded
ECHO DEPTHSOUNDER INOPERABLE.
Engineering
Issued 9 April 1996
Resolved
Repair the fuel vent for the # 3 fuel oil tank. Vent was holed on the top.Vessel made repairs to the vent prior to completion of the examination.
Navigation
Issued 9 April 1996
Resolved
Prove proper operation of the rudder indicator on the emergency steering system IAW SOLAS 60, chapter II, regulation 29(a)(iv). Rudder indicator is 10 degrees misaligned at the steering stand from the actual rudder position.
Fire Fighting
Issued 9 April 1996
Resolved
Prove proper operation of the emergency fire pump IAW SOLAS 74, chapter II-2, regulation 21. Motor was operational but the pump was unable to maintainsuction. Prior to completion of the examination, the pump was repaired andtested satisfactory with sufficient pressure.
Lifesaving
Issued 9 April 1996
Resolved
Provide a SOLAS Training Manual in each crew messroom and recreation room or each crew cabin that complies with the requirements of SOLAS 74, chapterIII, regulation 18.2. The contents of the manual must meet all the requirements of regulation 51.
Lifesaving
Issued 9 April 1996
Resolved
Properly mark the total number of persons that can be accomodated by both lifeboats. Both life boats were improperly marked with total capacity of 59 in one area and 50 in another of the hull. The Safety [name withheld] stated the total persons was 30.
Construction/Loadline
Issued 28 October 1995
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIR TO PIN HOLE, PORTSIDE ON #3 HATCH COVER.
Documentation
Issued 9 June 1995
Resolved
NO APPROVED SOPEP ON BOARD VESSEL. VESSEL TO PROVIDE A 25K LOU PRIOR TO DEPARTURE PORT OF NOLA.
Fire Fighting
Issued 9 June 1995
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP (NO SUCTION).
Fire Fighting
Issued 9 December 1994
Resolved
FIRE PUMP/GENERAL SERVICE PUMP PIPE SOFT PATCHED. SOLAS
Fire Fighting
Issued 9 December 1994
Resolved
FIREMAIN/GENERAL SERVICE PIPING DISCONNECTED IN ENGINEROOM. SOLAS
Accommodation/Occupational Safety
Issued 9 December 1994
Resolved
SEWAGE OVERBOARD PIPING SOFT PATCHED AT OVERBOARD VALVE. SOLAS
Fire Fighting
Issued 9 December 1994
Resolved
FIRE PUMP/GENERAL SERVICE PUMP STRAINER TEMPORARY PLUG IN DRAIN. SOLAS
Construction/Loadline
Issued 9 December 1994
Resolved
BALLAST PIPING AT BOTH MANIFOLDS MISSING. SOLAS
Construction/Loadline
Issued 9 December 1994
Resolved
DECK HOUSE DOOR TO #5 CARGO HOLD WASTED. LOADLINE_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 9 December 1994
Resolved
BUNKERS VENT CONTAINMENT FOR #2 BUNKER TANK WASTED THRU BETWEEN HOLDS 2 AND3.
Engineering
Issued 9 December 1994
Resolved
AIR COMPRESSOR COOLERS SALT WATER PIPING LEAKING. SOLAS _x001C_ REPAIR/REPLACE PIPING PRIOR TO NEXT U.S. PORT.
Engineering
Issued 9 December 1994
Resolved
CONDENSATE COOLER SALT WATER PIPING LEAKING. SOLAS _x001C_ REPAIR/REPLACE PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 9 December 1994
Resolved
WALKWAY RUSTED THRU BETWEEN CARGO HOLDS 4 AND 5. ILO 147 _x001C_ RENEW WASTED PLATING ON WALKWAY PRIOR TO NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 9 December 1994
Resolved
SEWAGE TREATMENT TANK LEAKING IN ENGINEROOM. 33 C.F.R. 159 _x001C_ REPAIR TANK PRIOR TO NEXT U.S. PORT.
Engineering
Issued 9 December 1994
Resolved
SOFT PATCH ON MAIN ENGINE LUBE OIL COOLER SALT WATER LINE. SOLAS _x001C_ RENEW PIPING PRIOR TO NEXT U.S. PORT.
Engineering
Issued 9 December 1994
Resolved
GENERAL SERVICE SALT WATER PIPING SOFT PATCHED IN SIX DIFFERENT PLACES IN ENGINEROOM. SOLAS PIPING SHOULD BE RENEWED PRIOR TO NEXT U.S. PORT.
Navigation
Issued 24 November 1994
Resolved
MANEUVERING FACT SHEET DID NOT MEET THE REQUIREMENTS OF 33 CFR 164.35(g) INTHAT IT WAS MISSING THE FOLLOWING: 1) TIME/DISTANCE TO STOP FOR HALF SPEED 2) TABLE OF RPM'S FOR REPRESENTATIVE SPEEDS 3) MANEUVERING INFO FOR NORMAL LOAD AND BALLAST CONDITIONS 4) WARNING STATEMENT AT THE BOTTOM OF SHEET.
Navigation
Issued 24 November 1994
Resolved
VSL ENTERED THE PORT OF NEW YORK WITHOUT A COPY OF THE 1994 U.S TIDAL CURRENT TABLES OR A FOREIGN EQUIVALENT AS REQUIRED BY 33 CFR 164.33(a)(3)(ii).
Navigation
Issued 24 November 1994
Resolved
VSL ENTERED THE PORT OF NEW YORK WITH NEW CHARTS #12333, 12334, AND 12327 NOT CORRECTED UP TO DATE AS REQUIRED BY 33 CFR 164.33(a)(1)(ii). IN ADDITION, THE VSL DID NOT HAVE ANY FOREIGN EQUIVALENTS FOR THE AREA TRANSITTED.
Lifesaving
Issued 18 August 1994
Resolved
During offloading a crane bucket broke off approximately 4-8 feet of railing on the hold access ladder. Master instructed to repair prior to NPOC. ILO 147.
Lifesaving
Issued 18 August 1994
Resolved
Improper houskeeping resulted in oil on deck from hydraulic hatch covers. This created a slippery condition. Master instructed to wipe up ASAP.
Navigation
Issued 22 May 1990
Resolved
US COAST PILOT NCTD AS REQUIRED BY 33CFR164.33(A)(2)(II).
Navigation
Issued 24 February 1988
Resolved
A VIO OF 33 CFR 164.11(R) IN THAT THE SECOND MARINE RADAR REQ BY 33 CFR 164.37(A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/WIN THE NAVIGABLE WATERS OF THE U.S.
Navigation
Issued 24 February 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 24 February 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE ON BOARD U.S. CHARTS 12230 OR 12263, OR THEIR FOREIGN EQUIVALENTS WHICH WERE REQUIRED FOR THE VSLS ROUTE FROM SMITH POINT VA TO BALTIMORE HBR.
Navigation
Issued 24 February 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO US COAST PILOT, (N.P. 69, VOL.II),USED BY THE VSL WAS NOT CORRECTED UP THRU SUPPLEMENT #5 WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM SMITH POINT VA TO BALTIMORE HBR. NO U.S. EQUIVALENT O/B.
Navigation
Issued 24 February 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO USCG LIGHT LIST (N.P. 82, VOL.J),USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 47/87,WHICHWERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM SMITH PT VA TO BALTIMORE HBR. NO U.S. EQUIVALENT ON BOARD.
Navigation
Issued 24 February 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO US CHART 12278 (UK: 2850),USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 2923,WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTEFROM SMITH POINT VA TO BALTIMORE HBR. NO US EQUIVALENT ON BOARD.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.