MAURY USCG vessel records Sign in
← All vessels

TRIAS

TRIAS is a 1977 freight ship. The Coast Guard has recorded 27 inspections since 1984, most recently in November 1999, along with 47 deficiencies and 1 operational control.

Records from 1984 to 1999. Most recent: inspection, 16 November 1999.

Built
1977
Last inspected
16 November 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7525827 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225614
Flag
GREECE
—
Maury page id
psix-225614

Inspections, by type

…with no type recorded25
Years with a record 15 calendar years (1984–1999)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8817 - Regulatory (Subpart C or D), Net Ton
24738 - Dead Weight, Ton
14382 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

16 November 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 434829
30 June 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430229
19 April 1999 Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 427575
10 August 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 419539
18 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 401933
13 December 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398390
16 January 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 386895
13 December 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 385905
28 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 381294
15 February 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 646595
9 February 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 646596
18 January 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 513848
17 January 1995 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 50103
11 February 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377122
2 January 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 363525
26 August 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 471650
19 January 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 355770
16 January 1993 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140467
9 July 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 439577
12 November 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 346969
8 November 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 444160
7 February 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 335178
14 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 329000
22 January 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320904
12 July 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310132
25 November 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 305602
18 June 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296705

Deficiency record · 47

Lifesaving
Issued 19 April 1999 Resolved
PROVIDE CLASS SOCIETY REPORT ATTESTING TO THE SATISFACTORY CONDITION OF LIFE BOAT RUDDER ASSEMBLY.
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Documentation
Issued 19 April 1999 Resolved
PROVIDE CLASS SOCIETY APPROVED SOPEP
Condition: Unknown
Due 30 June 1999
Resolved 30 June 1999
Lifesaving
Issued 13 December 1996 Resolved
Replace the missing belt drive guards over the emergency air compressor, reefer compressor and A/C unit prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11.
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Clean the excessive oil from about the DOTP, M/E L/O pumps, HOTP, all purifiers, mid level fwd tank trays and steering gear decks & machinery. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/65
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Renew the deteriorated deck plate adjacent to the stbd, lower level fire hose station prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 13 December 1996 Resolved
Replace all missing hatch cleats on the cargo hatches. Renew any excessively wasted cleats and missing / broken clips. Complete prior to departure. _x001C_ ICLL 66 II/16
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 13 December 1996 Resolved
Repair the wasted and holed galley vent / fan adjacent to the A/C space prior to departure. _x001C_ _x001C_ ICLL 66 II/19
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 13 December 1996 Resolved
Replace all missing nuts and bolts on the topside ballast tank openings. All tank entrances should be inspected. Complete prior to departure. _x001C_ _x001C_ ICLL 66 II/18
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Make permanent repairs to the riser, overhead, and aft run of piping from the port fire pump as it is badly wasted & leaking in multiple areas. Complete prior to departure. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Make permanent repairs to the wasted & leaking cooling line to the generators (from the DOTP (fwd) to the engine heat exchangers). Complete prior to departure. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Renew the wasted foam line in the steering gear space to the engineroom tank tops prior to departure. _x001C_ _x001C_ SOLAS 60 II/65.g
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Replace the missing cap on the potable water fill line (port, aft deck) prior to return to a U. S. port. _x001C_ _x001C_ ICLL 66 II/20
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Provide mechanical plugs form all fuel vent containments prior to return toa U. S. port. _x001C_ _x001C_ 33 CFR 155.320.a
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Prove proper operation of the emergency air compressor prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 13 December 1996 Resolved
Repair the hole in the stbd coaming of the #4 hatch cover prior to departure. _x001C_ _x001C_ ICLL 66 II/14
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Remove the paint from behind the main switchboard and from about the steering gear and move to the approved paint locker. Complete prior to return to a U. S. port. _x001C_ SOLAS 74 amd II-2/18.7
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Provide a class report on the damaged air intake filter housings on the outboard generator engines. (The covers essentially have holes in them.) Make repairs as required by class. Complete prior to return to a U. S. port. SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Electrical
Issued 13 December 1996 Resolved
Remove / repair the electrical wiring mess on the auxiliary boiler burner prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Electrical
Issued 13 December 1996 Resolved
Remove the unprotected heat lamps on the steering gear motors (replace with heat strips if necessary) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Navigation
Issued 13 December 1996 Resolved
Provide cotter pin or double nut connections for all steering gear linkagesprior to return to a U. S. port. _x001C_ _x001C_ MSM II.14
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Remove the ropes holding the fire doors open between the engineroom and emergency fire pump space prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/54.
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Repair the D/O leaks from the tank above the emergency fire pump prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/65.b
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Deck/Cargo
Issued 13 December 1996 Resolved
Repair the hydraulic leaks on the stbd anchor windlass prior to return to aU. S. port. _x001C_ _x001C_ 33 CFR 151.10.b
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Make permanent repairs to the cooling piping about the 4 M/E heat exchangers as it is wasted & leaking in multiple areas. Complete prior to departure. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Make permanent repairs to the generator engine's heat exchanger (stbd) piping where wasted. Complete prior to departure. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Make permanent repairs to the port F/W generator ejector line overboard where wasted above the sea valve. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 13 December 1996 Resolved
Make permanent repairs to the port fire pump suction manifold where it is extensively patched with steel plates. Complete prior to return to a U. S.port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Make permanent repairs to the numerous overboard drains in the stbd, aft, LL engineroom where they are wasted & leaking (above sea valve). Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Make permanent repairs to the wasted & leaking sewage line over the stbd generator engine. Complete prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Make permanent repairs to the reefer compressor heat exchanger bells where they are wasted & holed. Complete prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Make permanent repairs to the cascade tank heat exchanger bell where it is wasted & holed. Complete prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Accommodation/Occupational Safety
Issued 13 December 1996 Resolved
Make permanent repairs to the water fill line adjacent (port) to the steering gear where extensively wasted. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
All E/R double bottom sounding tubes need to be inspected (by class) to assure gravity closure handles are present & freely working and that they remain in a closed position. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Electrical
Issued 13 December 1996 Resolved
Remove the jury-rigged light over the port, fwd, LL sounding tube and the M/E RPM indicator (port, aft, mid level of MDE) prior to return to a U. S. port. _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Investigate the oil leak on the stern tube (interior) and provide a class recommendation for necessary repairs. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Repair the oil leaks on the underside of the M/E air box. Several fittings& seals have become loose; leaking oil. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Engineering
Issued 13 December 1996 Resolved
Clean the excessive oil accumulations about the M/E telescoping piston cooling lines where they are shielded by cardboard. Repair any excessive leaks. Complete prior to return to a U. S. port. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Electrical
Issued 13 December 1996 Resolved
Replace the worn electrical mats in front of the main switchboards prior toreturn to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Electrical
Issued 13 December 1996 Resolved
Eliminate the full ground in the 115 volt circuit prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 II/27
Condition: Unknown
Due 31 December 1996
Resolved 18 December 1996
Navigation
Issued 13 December 1995 Resolved
PROVIDE A WEAK LINK OR FLOAT FREE DEVICE AND PROPERLY ATTACH TO EPIRB.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Lifesaving
Issued 13 December 1995 Resolved
PROVIDE 2 - SCBA'S, 2 - SAFETY LAMPS, 2 HARNESSES, AND AN AX TO MAKE TWO COMPLETE FIREFIGHTING OUTFITS.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Navigation
Issued 13 December 1995 Resolved
PROVIDE A GALVESTON APPROACH CHART AND A COAST PILOT VOLUME 5.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Fire Fighting
Issued 13 December 1995 Resolved
MAKE PERMANENT REPAIRS TO THE 2 1/2" HOLE IN THE MAIN FIREFIGHTING LINE IN THE ENGINE ROOM AT THE SEWAGE HOLDING TANK.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Fire Fighting
Issued 13 December 1995 Resolved
UPDATE THE FIRE CONTROL PLAN TO REFLECT ALL EQUIPMENT AND THEIR LOCATIONS.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Fire Fighting
Issued 13 December 1995 Resolved
PROVIDE THREE FIRE HOSE TO MAKE A TOTAL OF FIVE FOR THE DECK CARGO AREA.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Accommodation/Occupational Safety
Issued 19 January 1993 Resolved
Vessel has a holding tank (type III MSD) that is not labeled. It cannot beexempted from labeling requirements if the sewage is not kept at ambient temerature or pressure.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Navigation
Issued 19 January 1993 Resolved
Outdated (1992) tide table and tidal current table on board.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994

Ownership record