MAURY USCG vessel records Sign in
← All vessels

RODANTHI

RODANTHI is a 1978 freight ship. The Coast Guard has recorded 17 inspections since 1990, most recently in May 2006, along with 16 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1990 to 2006. Most recent: inspection, 12 May 2006.

Built
1978
Last inspected
12 May 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7526687 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225637
Flag
PANAMA
—
Maury page id
psix-225637

Inspections, by type

…with no type recorded10
…past their stated due date1
Years with a record 10 calendar years (1990–2006)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14930 - Regulatory (Subpart C or D), Net Ton
14930 - Convention (Subpart B), Net Ton
44750 - Dead Weight, Metric Ton
53980 - Displacement, Metric Ton
26194 - Regulatory (Subpart C or D), Gross Ton
26194 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

12 May 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2647811
5 May 2006 Deficiency Check · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2639366
19 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2275199
19 January 2005 ISPS I Exam · Deficiency Check · PI Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2277256
12 January 2005 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2273703
20 August 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2170993
5 January 2004 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1975097
23 August 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1889430
18 August 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1879923
12 July 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1643264
8 May 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 415779
11 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402537
8 December 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 645353
7 November 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 384406
1 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376441
3 June 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 350992
2 February 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 335232

Deficiency record · 16

Operations/Management › Pollution › Control of Discharge of Oil
Issued 5 May 2006 Resolved
Vessel missing non-tank vessel response plan. Informed master and owner agent of regulations. Supplied owners agent with NVIC for VRP.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 May 2006
Resolution: Received proper documentation satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 5 May 2006 No resolution recorded
Vessel has an inoperable spare radar. Requested agent send copy of technicians report attesting to repairs.
Due 5 June 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 January 2005 Resolved
Repair railing on fore'castle and ladder to fore'castle damaged during storm.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 July 2005
Resolved 5 May 2006
Resolution: Forecastle ladder and railing have been repaired.
Lifesaving › Lifeboat › Propulsion Engine
Issued 19 January 2005 Resolved
Starboard lifeboat failed to start. Engineer and two additional crewmembers tried for approx. 15 min.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2005
Construction/Loadline › Structures › Door
Issued 19 January 2005 Resolved
Port watercloset door, located outside of superstructure on main deck had wasted hinges that gave way during recent heavy weather.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 19 January 2005 Resolved
Provide operating instructions for CO2 system for main engine crank cases.
Condition: Unknown
Due 26 January 2005
Resolved 26 January 2005
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 August 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2004
Resolved 23 August 2004
Resolution: Recieved documentation from Malta satisfying requirement.
Personnel › Certificates/Documents/Licenses › STCW Certificate, OIC of Navigational Watch
Issued 20 August 2004 Resolved
The Third Officer's flag state endorsement states that he cannot serve as officer of a navigational watch on vessels with ARPA and as such the vessel is not adequately manned in accordance with the Safe Manning Certificate. Additionally, his endorsement does not reference his current national license as required by STCW 95 A/I/2.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2004
Resolved 23 August 2004
Resolution: Recieved documentation from Malta satisfying requirement.
Accommodation/Occupational Safety › Occupational Safety
Issued 12 July 2002 Resolved
Replace /Renew light fixture in hospital space.
Condition: Unknown
Due 12 August 2002
Resolved 16 July 2002
Resolution: light fixture was replace/renew
Accommodation/Occupational Safety › Occupational Safety
Issued 12 July 2002 Resolved
Provide a safety guard on moving parts of emergency generator located on the foward part of the generator.
Condition: Unknown
Due 12 August 2002
Resolved 16 July 2002
Resolution: safety guard was provided
Documentation › Safety/Response Plans/Programs
Issued 12 July 2002 Resolved
Update fire control plan to reflect current position of all fire lockers with firemans outfits. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 12 August 2002
Resolved 16 July 2002
Resolution: fire control is updated
Documentation › Safety/Response Plans/Programs
Issued 12 July 2002 Resolved
Provide updated fire control plans refecting location of international shore connection and fire lockers as pre SOLAS 74 amendment II-2/20.2. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 12 August 2002
Resolved 16 July 2002
Resolution: fire control plans reflect location of international shore connection and fire lockers
Lifesaving
Issued 8 May 1998 Resolved
MOVE ALL CHEMICAL CONTAINERS AND OIL DRUMS IN ENGINE ROOM.
Condition: Unknown
Due 8 June 1998
Resolved 3 July 1998
Construction/Loadline
Issued 8 May 1998 Resolved
SEWAGE OVERBOARD CEMENT PATCH, MAIN COOLING WATER SUPPLY PATCH, AND LEAKINGFORWARD SHAFT SEAL. NEEDS CLASS SURVEY.
Condition: Unknown
Due 11 May 1998
Resolved 3 July 1998
Documentation
Issued 7 November 1995 Resolved
Certiricate of Finacial responcibility expired on 06NOV95._x001C_
Condition: Unknown
Due 7 November 1995
Resolved 4 December 1995
Lifesaving
Issued 7 November 1995 Resolved
The lifering buoys used on the quick release smoke/light were not 4kgs as required by SOLAS III/31.1.7
Condition: Unknown
Due 8 November 1995
Resolved 4 December 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.