MAURY USCG vessel records Sign in
← All vessels

CARAVOS GALAXY

CARAVOS GALAXY is a 1978 freight ship. The Coast Guard has recorded 45 inspections since 1985, most recently in February 2009, along with 49 deficiencies and 9 operational controls, 1 with no removal date recorded.

Records from 1985 to 2009. Most recent: inspection, 17 February 2009.

Built
1978
Last inspected
17 February 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7527186 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225646
Flag
SWITZERLAND
—
Maury page id
psix-225646

Inspections, by type

…with no type recorded35
Years with a record 18 calendar years (1985–2009)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19990 - Regulatory (Subpart C or D), Net Ton
61744 - Dead Weight, Ton
36199 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

17 February 2009 Loadline Exam · MARPOL Annex V Examination · Ballast Water Examination · STCW 95 Exam · PII Safety Exam · ILO-147 Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3418806
16 January 2009 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3395355
12 June 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3235204
9 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3231985
28 November 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2541842
11 September 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2489239
24 August 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2473054
3 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2285833
2 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2285118
9 December 2004 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2256200
8 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2258095
7 December 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2255355
12 October 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2219110
10 August 2004 ISPS II Exam · NPV Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2161599
10 August 2004 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2162560
31 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2035870
9 April 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1771168
25 March 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 288232
29 October 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 434252
15 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 425965
29 December 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 424186
22 June 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 416888
21 November 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 397598
5 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 709309
30 August 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 395030
5 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 460720
1 April 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389664
29 March 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389495
26 February 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388392
7 October 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383629
18 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380840
5 October 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 864120
10 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 369372
10 August 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 369373
10 August 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 863472
4 January 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 355458
20 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 443493
13 August 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 338753
23 February 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 486265
25 July 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331639
14 May 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 323308
11 September 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 440867
20 February 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314449
27 November 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 437416
25 February 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300430

Deficiency record · 49

Fire Fighting › Fire Main › Condition
Issued 18 February 2009 Resolved
Fire main on main cargo hold cracked and deteriorated in way of No. 4 and No. 7 cargo holds are severely leaking. Deficiency to be rectified prior to departure with class to witness and inspect operational test of fire main system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Received class report indicating that deficiency issued for fire main system has been repaired to its satisfaction.
Electrical › Electric Generation Source (service) › Generator
Issued 12 June 2008 Resolved
1499 - Vessel's number 2 ship service generator has an exhaust leak. Vessel shake make repairs to the exhaust leak and submit report from class attesting to the proper operation. - SOLAS 60 Con. CH. 1 Reg. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2008
Resolved 16 June 2008
Resolution: Received a report from class attesting to the deficiency which have been rectified.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 12 June 2008 Resolved
1499 - The #2 turbo charger on the vessel's main engine has an exhaust leak. The vessel shall have repairs and proper operation attested by certificate issuing authority. - SOLAS 60 Con. CH#1 Reg. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2008
Resolved 16 June 2008
Resolution: Received a report from class attesting to the deficiency which have been rectified.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 12 June 2008 Resolved
1499 - The vessel's incinerator has several exhaust leaks and the refractory bricks have several cracks. Vessel shall make repairs and have proper operation attested to by certificate issuing authority. - SOLAS 60 Con. CH.1 Reg. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2008
Resolved 16 June 2008
Resolution: Received a report from class attesting to the deficiency which have been rectified.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 12 June 2008 Resolved
1499 - Vessel's main fire pump is spraying sea water excessively. Prior to departure, vessel must submit class report attesting to proper operation. - SOLAS 60 CH.1 Reg. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2008
Resolved 16 June 2008
Resolution: Received a report from class attesting to the deficiency which have been rectified.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 June 2008 Resolved
1499 - The vessel's emergency Generator's radiator cap is missing. Vessel must replace missing cap and have certificate issuing authority attest to the proper operation of the cooling water system. - SOLAS 60 CH.II Reg. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2008
Resolved 16 June 2008
Resolution: Received a report from class attesting to the deficiency which have been rectified.
Fire Fighting › Fire Main › Condition
Issued 24 August 2005 Resolved
Vessels fire main piping system was found to have (02) holes in piping. One was found on the starboard side near the forward part of #7 cargo hold. The other was found on a hydrant line running off of fire main in between #6 and #7 cargo holds. Vessel must repair firemain to the satisfaction of class prior to departure. Cite SOLAS 60 Ch. II Part E Reg. 66.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2005
Resolution: Class faxed report of repairs to Sector Delaware Bay
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 24 August 2005 Resolved
The vessels reefer alarm was not working properly. Cite ILO 147
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 29 September 2005
Resolution: Alarm was found to be working.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 August 2005 Resolved
Hand rail leading down to vessels dry stores broken. Cite ILO 147
Due 29 September 2005
Resolved 29 September 2005
Resolution: Hand rail repaired.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 24 August 2005 Resolved
Vessel did not submit ballast water reporting form. Cite 33 CFR 151.2041
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2005
Resolved 29 August 2005
Resolution: Report submitted
Navigation › Collision/Grounding Avoidance › Radar
Issued 2 February 2005 Resolved
MSO PHILADELPHIA ISSUED LOD 08 - 05 TO M/V CARAVOS GALAXY FOR AN INOPERABLE X-BAND RADAR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2005
Resolved 12 February 2005
Resolution: INOP X-BAND INSPECTED AND TESTED TO THE SATISFACTION OF THE REPAIR TECHNICIAN. MSO PHILADELPHIA RESCINDED LOD 08 - 05.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 9 December 2004 Resolved
Berthing area room #409 family (B) adjacent to drying room and storeroom. There is no steel bulkhead to separate the rooms as per ILO 147.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2004
Resolution: Clothing and micellanous items were removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 December 2004 Resolved
Light fixture in cabin #401 missing light covers on both light fixtures. ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2004
Resolution: Both light fixtures now have covers place over both of them.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 9 December 2004 Resolved
Right windoW located in cabin #407 has rags stuffed between bulkhead and window to protect from water and cold from entering the space. ILO 147. Have Class attest to the repairs of window.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2004
Resolution: Received Class report attesting to a new rubber casket was placed between the bulkhead and the window frame. All sat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 December 2004 Resolved
Stairs leading to provision(s) in the Galley - 4th step gave way and foot went through step.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2004
Resolution: Received Class report attesting to the repairs of four new steps including the 4th step leading to provision(s) store.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 December 2004 Resolved
Vessel did not have water or heat due to PMS on vessels Boiler.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2004
Resolution: Coast Guard personnel attested to vessel having heat and hot water after PMS was complete on vessels boiler.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 9 December 2004 Resolved
Door handles missing on passageway doors on (C) deck. ILO 147.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2004
Resolution: Received Class report attesting to the installation of new door handles on passageway doors.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 9 December 2004 Resolved
During Coast Guard boarding validity of Philippine licenses were questioned as well as the STCW Certificates. Based on these findings vessel does not meet minimum mannig requirements under SOLAS. Vessel is instructed to contact Flag Administration to rectify this situation. [name withheld], Chief Mate, 2nd Mate and 3rd Mate licenses are in question.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifeboat Equipment › Food Ration
Issued 10 August 2004 Resolved
VESSELS PORT AND STARBOARD LIFEBOATS WERE EACH MISSING (12) FOOD RATIONS. MUST BE CORRECTED PRIOR TO DEPARTURE. CITE SOLAS 74 CH. IV 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2004
Resolution: New lifeboat rations now on board. Deficiency corrected.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 10 August 2004 Resolved
VESSELS REEFER FANS DO NOT HAVE COVERS. MUST BE CORRECTED PRIOR TO DEPARTURE. CITE ILO 147
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2004
Resolution: Fans are now properly covered. Deficiency corrected.
Construction/Loadline › Structures › Door
Issued 10 August 2004 Resolved
DOORS ON SUPERSTRUCTURE DO NOT CLOSE PROPERLY OR LOCK. STARBOARD SIDE DOOR ON SECOND DECK IS WASTED. MUST ENSURE ALL VESSEL DOORS CLOSE PROPERLY AND LOCK PROPERLY WITHIN 7 DAYS TO SATISFACTION OF CLASS. CITE ILLC 66 ANNEX V REG 12
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 16 August 2004
Resolution: Doors are now properly closing and locking. Deficiency corrected.
Construction/Loadline › Structures › Door
Issued 10 August 2004 Resolved
WINDOW IN CABIN SPACE #406 IS NOT PERMANANTLY ATTACHED TO THE BULKHEAD. RAGS ARE STUFFED INTO WINDOW TO PROTECT WATER FROM ENTERING SPACE. MUST BE CORRECTED TO THE SATISFACTION OF CLASS WITHIN 7 DAYS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 16 August 2004
Resolution: RECEIVED RECEIPT FOR PURCHASE OF NEW WINDOW AND MATERIALS TO PROPERLY CORRECT DEFICIENCY.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 August 2004 Resolved
CABIN SPACE #406 DOES NOT HAVE READING LAMP ABOVE RACK. MUST BE CORRECTED TO THE SATISFACTION OF CLASS WITHIN 7 DAYS. CITE ILO 147
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 16 August 2004
Resolution: deficiency corrected
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 August 2004 Resolved
CABIN SPACE #406 AND #407 DO NOT HAVE HOT FRESH WATER. CABIN SPACE #406 SINK LEAKS EXCESSIVLY WHEN VALVE IS OPENED. MUST BE CORRECTED TO THE SATISFACTION OF CLASS WITHIN 7 DAYS. CITE ILO 147
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 16 August 2004
Resolution: Both cabins now have hot water. Leaking sink in 406 has been fixed. Deficiency corrected.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 10 August 2004 Resolved
EMERGENCY GENERATORS HYRAULIC OIL SYSTEM IS LEAKING EXCESSIVELY. MUST BE CORRECTED TO THE SATISFATION OF CLASS WITHIN 7 DAYS. CITE SOLAS 74 CH. II-I REG 44
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 16 August 2004
Resolution: Witessed generator leak was fixed. Deficiency corrected.
Fire Fighting › Means of Escape › Doorways
Issued 10 August 2004 Resolved
ENGINE ROOM ESCAPE HATCH IS NOT SELF CLOSING. MUST BE CORRECTED PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2004
Resolution: Witnessed escape hatch closing properly. Deficiency corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 9 April 2003 Resolved
Existing dry powder extinguishing system for boiler to be recharged/reinstalled or replaced entirely. Class to address necessity of system and time allowed for repair or replacement. Provide report to USCG MSO Mobile. SOLAS 60 II/ Part e Regulation 57. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2003
Resolution: Vessel considered to be adequately covered for voyage to New Orleans and Flag state agreement of alternative or removal of DP system to be provided to class prior to departure from New Orleans.
Operations/Management › Drills/Instruction
Issued 9 April 2003 Resolved
Fire/Abandon ship drills unsatisfactory, to be performed to the satisfaction of U.S. Coast Guard LEGACY COMPONENT DESC: Abandon Ship
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2003
Resolution: Fire/Abandon ship drills were conducted to the satisfaction of the U.S. Coast Guard.
Accommodation/Occupational Safety › Washroom/Toilet
Issued 9 April 2003 Resolved
Vessel to make repairs toilets in hospitals and crew cabins to all water in hospital and crew cabins. Vessel to provide cold/hot freshwater to be provided in hospital wash spaces. Repairs to satisfaction of flag state. Provide report to USCG MSO Mobile. PWSA 33 USC 1223 (b) LEGACY COMPONENT DESC: Hot and Cold Running Water
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2003
Resolution: Hot and cold running fresh water supplies reinstated in hospital wash spaces and considered satisfactory. Levers on flushing valves of toilets in accomodation partially complete with additional spares awaiting vessel in New Orleans, repairs satisfactory.
Pollution Prevention/Response › Prevention Equipment
Issued 9 April 2003 Resolved
Leaking sewage pipe forward off ballast valve control board. Pipe to be repaired to the satisfaction flag state. Provide report to USCG MSO Mobile. LEGACY COMPONENT DESC: Sewage System Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2003
Resolution: 1.5 section of sewage pipe cropped out and replaced. Tested under working conditions and now considered satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 April 2003 Resolved
Open paint cans contained in engine room needs to be removed to the satisfaction of U.S. Coast Guard. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2003
Resolution: Paint cans in the engine room were removed.
Fire Fighting
Issued 29 October 1999 Resolved
2 International Shore Connections missing gaskets, bolts, nuts and flatwashers as required by SOLAS 74 REG II/19.4
Condition: Unknown
Due 31 October 1999
Resolved 1 November 1999
Navigation
Issued 29 October 1999 Resolved
During Emergency Steering Drill, rudder could only move to 15 Port and backto midships, could not move to Stbd.
Condition: Unknown
Due 31 October 1999
Resolved 1 November 1999
Navigation
Issued 29 October 1999 Resolved
GMDSS and EPIRB require repairs for maintenance as per SOLAS 74 Reg IV/7.6
Condition: Unknown
Due 31 October 1999
Resolved 1 November 1999
Navigation
Issued 29 October 1999 Resolved
U.S. charts 12311, 12312, and 12314 not currently corrected.
Condition: Unknown
Due 31 October 1999
Resolved 1 November 1999
Navigation
Issued 22 June 1998 Resolved
PROVIDE A CURRENT LIGHT ON BOARD PRIOR TO RETURNING TO THE PORT OF TAMPA.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Navigation
Issued 22 June 1998 Resolved
PROVIDE AN ANGLE RUDDER INDICATOR WITH EASY-TO-READ DEGREE MARKINGS IN THE STEERING GEAR ROOM PRIOR TO DEPARTURE.
Condition: Unknown
Due 23 June 1998
Resolved 25 June 1998
Navigation
Issued 22 June 1998 Resolved
PROVIDE EMERGENCY STEERING INSTRUCTIONS IN STEERING ROOM PRIOR TO DEPARTURE.
Condition: Unknown
Due 23 June 1998
Resolved 25 June 1998
Fire Fighting
Issued 30 August 1996 Resolved
THE VESSELS FIRE CONTROL DID NOT INCLUDE THE LOCATION OF THE EMERGENCY FIREPUMP. THE VESSEL WAS INSTRUCTED TO CORRECT THE DEFICIENCY PRIOR TO NEXT U.S. PORT._x001C_
Condition: Unknown
Due 22 November 1996
Resolved 21 November 1996
Navigation
Issued 30 August 1996 Resolved
THE VESSELS B/A CHARTS 1082, 1063, 1081, AND 899 WERE NOT CURRENTLY CORRECTED, THE CORRECTIONS WERE OUTDATED BACK TO MARCH 1996._x001C_ THE VESSEL CORRECTED THE DEFICIENCY PROIR TO DEPARTING.
Condition: Unknown
Due 3 September 1996
Resolved 3 September 1996
Deck/Cargo
Issued 30 August 1996 Resolved
THE VESSELS SMALL DISCHARGE CONTAINMENT AROUND THE VESSELS MANIFOLDS DID NOT HAVE MEANS OF MECHANICAL CLOSURE, THE THREADS WERE STRIPPED IN ALL _x001C_ CONTAINMENT AREARS, THE VESSEL WAS INSTRUCTED TO CORRECT THE DEFICIENCY PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Fire Fighting
Issued 30 August 1996 Resolved
THE VESSEL FAILED THE FIREFIGHTING DRILLS TWICE, THE VESSEL WAS DETAINED INPORT ONE DAY, AND PASSED THE FIREFIGHTING DRILL THE DAY.
Condition: Unknown
Due 3 September 1996
Resolved 3 September 1996
Fire Fighting
Issued 30 August 1996 Resolved
THREE OF THE VESSELS FIRE NOZZLES WERE NOT FULLY FUNCTIONING PROPERLY. THE VESSELS WAS INSTRUCTED TO CHECK ALL FIRE NOZZLES PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 21 November 1996
Resolved 21 November 1996
Documentation
Issued 26 February 1996 Resolved
A VIO OF 33 CFR 151.27 IN THAT THE SOPEP WAS NOT ABOARD_x001C_ _x001C_ _x001C_ IAW W/ LLOYDS CONDITIONAL IOPP VSL MUST HAVE SOPEP ON BOARD NLT 31MAR96
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Electrical
Issued 18 July 1995 Resolved
NONCONDUCTIVE MATTING AROUND HIGH VOLTAGE ELECTRICAL PANELS MISSING.
Condition: Unknown
Due 9 October 1995
Resolved 9 October 1995
Fire Fighting
Issued 18 July 1995 Resolved
FIRE HOSES AT FORWARD POSITIONED FIRE STATIONS MISSING. REPLACE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 9 October 1995
Resolved 9 October 1995
Lifesaving
Issued 10 August 1994 Resolved
Install proper weak link asembly on port and starboard liferafts. SOALS CH. III REG 38.6.2
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Fire Fighting
Issued 10 August 1994 Resolved
Make permenat repairs to fire main where holed. SOLAS CH. II-2 REG_x001C_ 4.1
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Navigation
Issued 13 August 1990 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT,VOL 3, USED BY THE VSL,WAS NOT CORRECTED TO NTM 16/90, WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO ALCOA TERMINALS._x001C_
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.