MAURY USCG vessel records Sign in
← All vessels

MARIA DIAMANTO

MARIA DIAMANTO is a 1976 freight ship. The Coast Guard has recorded 16 inspections since 1984, most recently in March 1999, along with 12 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 1984 to 1999. Most recent: inspection, 15 March 1999.

Built
1976
Last inspected
15 March 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7530365 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225682
Flag
GREECE
—
Maury page id
psix-225682

Inspections, by type

…with no type recorded15
Years with a record 10 calendar years (1984–1999)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6286 - Regulatory (Subpart C or D), Net Ton
17538 - Dead Weight, Ton
10337 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

15 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426532
13 May 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 415918
4 May 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 756194
3 May 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 415592
3 March 1998 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 193419
16 September 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395484
21 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382051
16 August 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 105723
2 December 1994 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1179732
29 September 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1429950
28 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 34775
4 October 1990 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339640
13 August 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317800
25 January 1986 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 306889
17 April 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 301377
16 September 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 526987

Deficiency record · 12

Construction/Loadline
Issued 3 May 1998 Resolved
CLASS SOCIETY TO DETERMINE CAUSE OF FUEL OIL IN THE BALLAST TANK SYSTEM ANDPROVIDE PROPOSAL FOR CORRECTION PRIOR TO DISCHARGING ANY BALLAST.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Fire Fighting
Issued 21 August 1995 Resolved
REPLACE LEAKING FIRE HOSE ON BOW.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Electrical
Issued 21 August 1995 Resolved
INSTALL NON-CONDUCTING MATTS IN WAY OF THE HIGH VOLTAGE SWITCH BOARD. CORRECT PRIOR TO NEXT U.S. PORT OR BY 21SEP95.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 21 August 1995 Resolved
REPLACE BROKEN LAMP GLOBE IN STEERING ROOM.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Accommodation/Occupational Safety
Issued 21 August 1995 Resolved
BOTH STARBOARD AND PORT SIDE TOILETS ON CREW DECK ARE INOP. THE PUMP THAT SUPPLIES THE WATER IS INOP. CORRECT PRIOR TO NEXT U.S. PORT OR BY 21SEP95.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 21 August 1995 Resolved
GRABLINE WASTED ON ALL LIFEBOUYS ON DECK, REPAIR AND MAKE GRABLINE SECURE.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Lifesaving
Issued 21 August 1995 Resolved
REPLACE WASTED RINGS THAT SECURE GRABLINE TO THE LIFEBOAT. CORRECT PRIOR TO NEXT U.S. PORT OR BY 21SEP95.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Fire Fighting
Issued 21 August 1995 Resolved
REPAIR SOUNDING TUBE TO EMERGENCY FIRE PUMP FUEL TANK. CORRECT PRIOR TO NEXT U.S. PORT OR BY 21SEP95.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Fire Fighting
Issued 21 August 1995 Resolved
PROVE OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 22 August 1995
Resolved 24 August 1995
Navigation
Issued 25 January 1986 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT A CURRENTLY CORRECTED U.S. COAST PILOTVOL 4 OR ITS EQUIV AS REQ BY 33 CFR 164.33(A)(2)(I) WAS NOT O/B.
Condition: Unknown
Due 25 January 1986
Resolved 25 January 1986
Navigation
Issued 25 January 1986 Resolved
A VIO OF 33 CFR 164.30 IN THAT A COMPLETE SET OF CURRENTLY CORRECTED U.S. CHARTS OR THEIR EQUIV OF THE AREA TRANSITED, AS REQ BY 33 CFR 164.33(A)(1) (II) WAS NOT O/B. NOS CHARTS 11520 & 11543 WERE ON BOARD BUT NOT CORRECTED UP TO DATE. CHART 11547 WAS NOT ABOARD.
Condition: Unknown
Due 25 January 1986
Resolved 25 January 1986
Documentation
Issued 25 January 1986 Resolved
OIL TRANSFER PROCEDURES REQUIRE UPDATING TO REFLECT INFORMATION REQUIRED BY 33 CFR 155.750. SPECIFIC PRODUCT INFO AND HANDLING INSTRUCTIONS ARE MISSING.
Condition: Unknown
Due 4 October 1990
Resolved 25 January 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.