Records from 1997 to 1998. Most recent: inspection, 11 October 1998.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
11 October 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 421431
5 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421070
24 April 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415380
14 October 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 408263
14 October 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 415120
Engineering
Issued 5 October 1998
Resolved
LEAKING F/O PUMP #3 GENERATOR_x001C_ SOLAS 60 REG II/34
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Electrical
Issued 5 October 1998
Resolved
LIGHT COVERS MISSING THROUGHOUT SHIP._x001C_ SOLAS 60 REG II/27A
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Electrical
Issued 5 October 1998
Resolved
35 EXPIRED EMERGENCY BATTERIES_x001C_ SOLAS 60 REGT II/26
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Accommodation/Occupational Safety
Issued 5 October 1998
Resolved
GREASE SCREENS MISSING FOR GALLEY GRILL._x001C_ ILO 147
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Engineering
Issued 5 October 1998
Resolved
FUEL IN GENERATOR BILGE_x001C_ SOLAS 60 REG II/34
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Fire Fighting
Issued 14 October 1997
Resolved
FIVE FIRE HOSES FOUND DETERIORATED/LEAKING.
Condition: Unknown
Due 14 October 1997
Resolved 29 October 1997
Navigation
Issued 14 October 1997
Resolved
NV PUB 102 NOT FOUND
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Fire Fighting
Issued 14 October 1997
Resolved
EMERGENCY FIRE PUMP ENGINE WOULD NOT START.
Condition: Unknown
Due 30 October 1997
Resolved 13 November 1997
Fire Fighting
Issued 14 October 1997
Resolved
CO2 ROOM LIGHTS INOPERABLE.
Condition: Unknown
Due 14 October 1997
Resolved 29 October 1997
Electrical
Issued 14 October 1997
Resolved
NUMROUS LIGHTS IN MACHINERY SPACES HAVE EXPOSED WIRES AND/OR MISSING COVERS. IN GENERAL, LIGHTS NOT IN WORKING ORDER.
Condition: Unknown
Due 14 October 1997
Resolved 29 October 1997
Lifesaving
Issued 14 October 1997
Resolved
CREW UNABLE TO CONDUCT PROPER ABANDON SHIP DRILL.
Condition: Unknown
Due 19 October 1997
Resolved 29 October 1997
Engineering
Issued 14 October 1997
Resolved
OWS DID NOT FUNCTION PROPERLY.
Condition: Unknown
Due 14 October 1997
Resolved 29 October 1997
Lifesaving
Issued 14 October 1997
Resolved
PORT LIFEBOAT HOLED IN WAY OF THE PORT BOW.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997