MAURY USCG vessel records Sign in
← All vessels

FLAG SUPPLIER

FLAG SUPPLIER is a 1978 freight ship. The Coast Guard has recorded 20 inspections since 1985, most recently in November 2004, along with 11 deficiencies and 1 operational control.

Records from 1985 to 2004. Most recent: operational control imposed, 16 November 2004.

Built
1978
Last inspected
16 November 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7533068 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225699
Flag
MALTA
—
Maury page id
psix-225699

Inspections, by type

…with no type recorded19
Years with a record 16 calendar years (1985–2004)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19515 - Regulatory (Subpart C or D), Net Ton
60914 - Dead Weight, Ton
72913 - Displacement, Ton
36255 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

16 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2242516
18 September 2004 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2198425
18 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286135
14 February 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274812
4 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274007
5 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418056
11 September 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407748
12 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 398461
24 September 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 383092
11 May 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 358227
23 August 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 352800
27 January 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 341523
19 July 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 484402
4 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 334558
8 September 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 449379
29 December 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 327551
9 January 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 320557
8 August 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 510892
10 September 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 311396
16 September 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 304566

Deficiency record · 11

Navigation
Issued 4 February 2000 Resolved
SOLAS 74 I/11 Stering alarms on bridge inoperative
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Navigation
Issued 4 February 2000 Resolved
SOLAS 60 III Tilt box actuator seals on steering leaking excessivly. Crew has a catch basin under leak draining to a 55 gal drum with a pump on top of the drum to pump oil back into sump
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Navigation
Issued 4 February 2000 Resolved
Steering repeater arms have no lock nuts or cotter pins installed
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Accommodation/Occupational Safety
Issued 4 February 2000 Resolved
33 CFR 159.7 No locks or Securing of overboard valve on the ships MSD. Vessel in US waters Mississippi River
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Construction/Loadline
Issued 4 February 2000 Resolved
Numerous Pumps in lower level of engin room leaking excessive ammounts of water and heavy oil into bilge.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Electrical
Issued 4 February 2000 Resolved
Vessel to repair leaking fuel oil injection pumps on #2 Generator #3 cylinder and #1 Generator #2 Cylinder
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Electrical
Issued 4 February 2000 Resolved
Vessel to replace missing cotter pins on fuel pumps for the fuel rack.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Engineering
Issued 4 February 2000 Resolved
The suction pipe from the boiler to the econimizer circulation pump is rusted through and has holes. Leaking water over piping and causing furtherdammage.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Navigation
Issued 23 August 1992 Resolved
Vessel did not have a U.S.C.G. light list onboard.
Condition: Unknown
Due 25 August 1992
Resolved 25 August 1992
Navigation
Issued 16 September 1985 Resolved
ECHO DEPTH SOUNDER INOPERABLE
Condition: Unknown
Due 16 September 1985
Resolved 16 September 1985
Navigation
Issued 16 September 1985 Resolved
ONE OF TWO RADARS INOPERABLE
Condition: Unknown
Due 16 September 1985
Resolved 16 September 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.