Records from 1984 to 1995. Most recent: inspection, 7 August 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 12
7 August 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 381271
27 February 1994
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 364790
11 July 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 344727
12 December 1990
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 480612
7 May 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 337050
16 May 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 330359
13 April 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 456313
3 September 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 325415
23 November 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 496638
2 May 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 315801
25 May 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 436636
7 December 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 299231
Construction/Loadline
Issued 7 August 1995
Resolved
MAKE PERMANENT REPAIRS TO STEM DOUBLER PLATE. (HOLED AT LAST FOREIGN PORT)
Condition: Unknown
Due 20 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 7 August 1995
Resolved
MAKE PERMANENT REPAIRS TO BALLAST CROSSOVER IN ENGINE ROOM. (SOFT PATCH) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 20 August 1998
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 7 August 1995
Resolved
PROVIDE CERTIFICATION LETTER FOR M.S.D.
Condition: Unknown
Due 20 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 August 1995
Resolved
REMOVE PAINT FROM AFT STEERING AND PLACE IN PAINT LOCKER. (FIRE HAZARD)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Lifesaving
Issued 7 August 1995
Resolved
REPAIR OR REPLACE HYDROSTATIC RELEASE FOR E.P.I.R.P. (BROKEN) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Construction/Loadline
Issued 7 August 1995
Resolved
REPAIR OR REPLACE GAUGE FOR BILGE PUMP. (WASTED) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Fire Fighting
Issued 7 August 1995
Resolved
REPAIR OR REPLACE VALVE STEM FOR FIRE HYDRANT IN ENGINE ROOM. (WASTED) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Fire Fighting
Issued 7 August 1995
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN PIPING. (LEAKS) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Fire Fighting
Issued 7 August 1995
Resolved
REPLACE FIREHOSE AFT MAIN DECK. (LEAKING) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Lifesaving
Issued 7 August 1995
Resolved
REPLACE GRAB LINE FOR 02 LIFE BUOYS. (DRY ROTTED) (CLASS TO VERIFY REPAIRS)
Condition: Unknown
Due 21 August 1995
Resolved 21 August 1995
Documentation
Issued 2 May 1987
Resolved
A VIO OF 33CFR155.820(A) IN THAT THE WRITTEN RECORD OF DESIGNATED PERSONS IN CHARGE OF OIL TRANSFER OPERATIONS WAS NOT AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Documentation
Issued 2 May 1987
Resolved
A VIO OF 33CFR155.740 IN THAT THE OTP REQ BY 33CFR155.750 WERE NOT AVAILABLE FOR INSPECTION BY THE COTP. THE VSL DID NOT HAVE ANY OTP O/B.
Condition: Unknown
Due 2 May 1987
Resolved 2 May 1987
Navigation
Issued 2 May 1987
Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART 12304 WHICH WAS REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPEN TO ARNOLD PT.
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995