← All vessels
STENWIL
STENWIL is a 1977 freight ship. The Coast Guard has recorded 18 inspections since 1988, most recently in May 2001, along with 15 deficiencies and 1 operational control.
Records from 1988 to 2001. Most recent: inspection, 18 May 2001.
- Built
- 1977
- Last inspected
- 18 May 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7600146 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225715
Flag
NORWAY
—
Maury page id
psix-225715
Inspections, by type
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8399 - Regulatory (Subpart C or D), Net Ton
20760 - Dead Weight, Ton
17956 - Regulatory (Subpart C or D), Gross Ton
20760 - Dead Weight, Ton
17956 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
18 May 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 290205
14 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290056
2 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434344
1 February 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 425024
14 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421114
27 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404104
16 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 386911
22 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 59554
22 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373648
22 December 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1159076
10 November 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 372374
1 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 516689
13 April 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366027
18 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 515043
18 February 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1373990
30 October 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 25965
30 October 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 479225
11 December 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 327272
Deficiency record · 15
Electrical
Issued 14 May 2001
Resolved
POSSIBLE EXHAUST LEAK NO.3 GENERATOR. PROVIDE CLASS REPORT.
Engineering
Issued 14 May 2001
Resolved
NO. 2 LUBE OIL PURIFIER DISASSEMBLED FOR MAINTENANCE. PROVIDE CLASS REPORT.
Lifesaving
Issued 14 May 2001
Resolved
EXCESSIVE FUEL/OIL SPRAY RESIDUE ON ENG ROOM MACHINERY, PIPING, AND DECKS IWO BALLAST PUMP. PROPERLY CLEAN AND REMOVE OILY RESIDUES.
Engineering
Issued 14 May 2001
Resolved
MULTIPLE SOFT PATCHES/TEMP REPAIRS ON MDE AND LUBE OIL COOLERS. PROVIDE CLASS REPORT.
Engineering
Issued 14 May 2001
Resolved
#2 & #3 GENERATORS DO NOT HAVE REQUIRED JACKETING ON ALL HIGH PRESSURE FUELINJECTOR LINES SOLAS 74A II-2/15.2.9
Electrical
Issued 14 May 2001
Resolved
EXCESSIVE FUEL OIL LEAKS ON ALL THREE SHIP'S SERVICE GENERATORS. REPAIR TO SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Lifesaving
Issued 14 May 2001
Resolved
PROVIDE VALID INSPECTION CERTIFICATES FOR INFLATABLE LIFERAFTS.
Accommodation/Occupational Safety
Issued 14 May 2001
Resolved
VESSEL INFESTED WITH INSECTS ON SEVERAL DECKS. PROVIDE DOCUMENTATION OF PROFESSIONAL EXTERMINATION SERVICE PRIOR TO DEPARTURE.
Electrical
Issued 14 May 2001
Resolved
JACKET WATER LEAKS ON NO. 3 GENERATOR. PROVIDE CLASS REPORT.
Lifesaving
Issued 14 May 2001
Resolved
EXCESSIVE OILY WASTES IN ENG ROOM BILGE SPACES. PROPERLY REMOVE OILY WASTES.
Engineering
Issued 14 May 2001
Resolved
#2 & #1 GENERATORS HAVE SOFT PATCHES ON JACKETING WATER COOLING WATER LINESSOLAS 74A I/11
Fire Fighting
Issued 2 November 1999
Resolved
PER SOLAS 60, REGULATION 56 (E)(ii) REPAIR LEAKING FIRE HYDRANT ON _x001C_ FORECASTLE._x001C_ _x001C_ _x001C_
Deck/Cargo
Issued 14 September 1998
Resolved
HYDRAULIC FLUID LEAKS ON CARGO DECK AREA FROM RAMS AND PIPING._x001C_ _x001C_ SOLAS 74 REG I/11_x001C_
Electrical
Issued 14 September 1998
Resolved
2 OF 3 MAIN GENERATORS INOPERATIVE._x001C_ _x001C_ SOLAS 74 REG I/11
Engineering
Issued 27 May 1997
Resolved
REPAIRS TO AUXILLARY BOILER IDENTIFIED DURING BUREAU VERITAS INSPECTION OF 02MAY97. THOSE REPAIRS MUST BE COMPLETED PRIOR TO 27JUN97.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.