Records from 1984 to 2001. Most recent: inspection, 4 September 2001.
Inspection history · 31
4 September 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 293382
20 July 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 292115
20 July 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 292171
23 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 283348
21 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 126780
15 August 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 280976
3 May 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277780
3 May 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279200
23 September 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 433082
5 August 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 431267
17 August 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 419236
6 August 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 418760
2 February 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 412262
8 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 410742
11 October 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 408956
7 October 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 408585
15 June 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 404674
13 January 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 132543
24 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 538122
22 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 395695
6 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 111983
15 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 383746
10 April 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 376842
19 February 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 375429
21 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333826
1 June 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 479202
16 July 1987
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 317362
15 December 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 305851
1 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 299055
14 September 1984
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 437451
10 September 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 297918
Fire Fighting
Issued 4 September 2001
Resolved
Provide faxed technicians report for the servicing of the fire fighting SCBA to the MSO Puget Sound office prior to departure. Solas 60/63(b)(2).
Condition: Unknown
Due 5 September 2001
Resolved 10 September 2001
Documentation
Issued 4 September 2001
Resolved
Provide faxed Solas Radio Certificate upon completion of radio survey in Tacoma, WA to the MSO Puget Sound.
Condition: Unknown
Due 5 September 2001
Resolved 10 September 2001
Fire Fighting
Issued 15 August 2000
Resolved
Update CO2 instructions and stencil cargo hold CO2 valves._x001C_ Correct prior to departure.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 15 August 2000
Resolved
Renew gauge to fire, bilge and ballast pump. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Engineering
Issued 15 August 2000
Resolved
Repair pipe where patched (2 places) at oily water seperator. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Electrical
Issued 15 August 2000
Resolved
Fabricate and install cover over exposed electrical connections at all three generators. SOLAS 60._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Deck/Cargo
Issued 15 August 2000
Resolved
Repair hydraulic ram where leaking at #2 pump and hydraulic controller where leaking at between #2 and #3 hatch. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Lifesaving
Issued 15 August 2000
Resolved
Renew batteries to PFD's where missing. SOLAS 74amd III/27._x001C_ Correct prior to departure.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 15 August 2000
Resolved
Renew insulation at emergency fire pump exhaust system. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Navigation
Issued 15 August 2000
Resolved
Vessel entered port with inoperable Gyro. Correct prior to departure.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 15 August 2000
Resolved
Fabricate and install hand guard at rotating at emergency fire pump. ILO 147._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Fire Fighting
Issued 15 August 2000
Resolved
Provide operating instructions for emergency fire pump. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Fire Fighting
Issued 15 August 2000
Resolved
Make hydraulic starter to emergency fire pump operable. SOLAS 60 I/11._x001C_ Correct prior to next U.S. port after sailing foreign.
Condition: Unknown
Due 19 December 2000
Resolved 19 December 2000
Fire Fighting
Issued 5 August 1999
Resolved
Repair mounting brackets for co2 bottles in co2 room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Engineering
Issued 6 August 1998
Resolved
Due to repair work being conducted on the Oily Water Separator the inspection team was unable to test and verify the Oily Water Separator was operational. Noted that this will be done upon arrival to next US Port. MARPOL 73/78 Annex 1/16.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Accommodation/Occupational Safety
Issued 8 December 1997
Resolved
HAND RAILS FOR ANGLED LADDERS LEADING INTO #1, #2 AND #3 CARGO HOLDS WERE MISSING.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Electrical
Issued 8 December 1997
Resolved
CAGES FOR GLASS GLOBES AT ENTERANCE TO SUPERSTRUCTURE ON MAIN DECK. SOLAS 74.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 7 October 1997
Resolved
Port and Stbd lifeboat seatbelt latches were "frozen" to the seats. SOLAS 74 Chapter III reg. 19.2.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 7 October 1997
Resolved
Port and Stbd lifeobats forward & aft hatches were not watertight. Need adjusting to ensure they close properly. SOLAS 74 Chapter III reg. 19.2.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Deck/Cargo
Issued 7 October 1997
Resolved
Handrails for ladders leading into #5 cargo holds were missing. Class inspected and required locks be placed on all accessways leading into the holds and the words "Danger-Ladder Missing-Do Not Use".
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Engineering
Issued 7 October 1997
Resolved
Containment for port bunker station, fuel oil tank vents for tank #4&5 portand stbd side were holed. 33 C.F.R. 155.320. Vessel must correct prior tonext bunkering operation or 31JAN98 whichever comes first._x001C_
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 7 October 1997
Resolved
Several cracks were noted near the #4 cargo hold. See PSNS for complete details.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 7 October 1997
Resolved
Watertight doors located around main deck and superstructure were wasted ornot adjusted properly. ICLL 66. Vessel must correct prior to return to U.S. from overseas or 31JAN98.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Accommodation/Occupational Safety
Issued 7 October 1997
Resolved
A/C room fire damper had holes and was wated on bottom. ICLL 66 Reg. 19&20. Vessel must correct prior to return to US from overseas or 31JAN98,whichever comes first.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Construction/Loadline
Issued 7 October 1997
Resolved
Battery room door wasted around edges. ICLL 66 regs. 19&20. Vessel must correct prior to next US port from overseas or 31JAN98, whichever comes first.
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Accommodation/Occupational Safety
Issued 7 October 1997
Resolved
Bridge deck port side vent next to bridge bulkhead is missing fire damper (means of shuting from outside source. Vessel must correct prior to return to U.S. or 31JAN98. ICLL 66 regs. 19&20._x001C_
Condition: Unknown
Due 8 December 1997
Resolved 8 December 1997
Accommodation/Occupational Safety
Issued 7 October 1997
Resolved
Ventilation on top of wheelhouse is wasted on inside edges. ICLL 66, regs 19&20.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 7 October 1997
Resolved
Water for port and stbd lifeboats is not satisfactory. Renew water and clean tank. SOLAS 74 Chapter III Reg. 8.9.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 7 October 1997
Resolved
#2 Crane stores vents wasted. ICLL Regs 19&20._x001C_
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Engineering
Issued 7 October 1997
Resolved
#5 HFO tank appeared to be "weeping" inside #5 cargo hold.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Navigation
Issued 7 October 1997
Resolved
Steering post has about 1/4" of "play". Class inspected and found a max. of 2mm and considered sat.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 7 October 1997
Resolved
Ballast vent #5 stbd side was holed. ICLL 66 reg. 19&20.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Fire Fighting
Issued 7 October 1997
Resolved
Piping for fire main was being repaired and thus, could not provide adequate pressure. SOLAS 74 Chapter III reg 19.2.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 7 October 1997
Resolved
Port/Stbd lifeboat brakes would not operate properly. SOLAS 74 Chapter IIIReg. 19.2. Class inspected and found satisfactory.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 7 October 1997
Resolved
Port side lifeboat's tracing pennants were wasted and broke during lowering.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Documentation
Issued 15 June 1997
Resolved
SOLAS TRAINING MANUAL, LIFESAVING AND EMERGENCY INSTRUCTIONS NOT WRITTEN INLANGUAGE(S) EASILY UNDERSTOOD BY THE CREW (SOLAS CHAP III, REGS 8, 51, 53).
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Lifesaving
Issued 15 October 1995
Resolved
REPAIR/REPLACE EXPLOSION PROOF LIGHT COVER IN PAINT LOCKER. CLASS SURVEYER INSPECTED AND GIVE CONDITION OF CLASS FOR THE ITEM TO BE CORRECT AT NEXT DRYDOCK.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Engineering
Issued 15 October 1995
Resolved
REPAIR/REPLACE CEMENT BOX PATCH ON MAIN ENGINE S/W COOLING (350MM) AND ON F/W GENERATOR S/W SUCTION (65MM). CLASS SURVEYER INSPECTED WITH CONDITION OF CLASS FOR THESE ITEMS TO BE CORRECTED AT NEXT DRY DOCK.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Navigation
Issued 15 December 1985
Resolved
VESSEL DID NOT HAVE MARINE CHARTS 11412, 11413, AND 11414 CURRENTLY CORRECTED. THE CHARTS WERE ALSO 1981 EDITIONS, NOT THE MOST RECENT EDITIONS.
Condition: Unknown
Due 22 August 1997
Resolved 22 August 1997