Records from 1987 to 2000. Most recent: inspection, 27 January 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Accommodation/Occupational Safety
Issued 27 January 2000
Resolved
RAW SEWAGE LEAKING FROM WASTED PIPING IN CREW'S HEAD B. CONNECTION TO COMMODE HOLED. REPAIR LEAK, CLEAN AREA OF RAW SEWAGE, AND SECURE SPACE UNTIL PERMANENT REPAIRS ARE MADE. MAKE PERMANENT REPAIRS PRIOR TO 01FEB00.
Condition: Unknown
Due 1 February 2000
Resolved 4 February 2000
Navigation
Issued 27 January 2000
No resolution recorded
U.S COAST PILOT BOOK NOT CURRENTLY CORRECTED.MAKE CORRECTIONS PRIOR TO 01FEB00.
Condition: Unknown
Due 1 February 2000 — due date passed with no resolution recorded
Documentation
Issued 27 January 2000
Resolved
UNABLE TO VERIFY VALIDITY OF C.O.F.R. VESSEL OPERATOR/USCG HEADQUARTERS CONTACTED AND COFR VERIFIED ON BOARD. CLEARED ON BOARD
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Navigation
Issued 27 January 2000
No resolution recorded
MANEUVERING FACT SHEET ON BRIDGE CONTAINED NO WARNING STATEMENT.
Condition: Unknown
Due 1 February 2000 — due date passed with no resolution recorded
Fire Fighting
Issued 27 January 2000
Resolved
FIRE MAIN CRACKED AT FIRE PUMP IN ENGINE ROOM. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM NEW YORK._x001C_
Condition: Unknown
Due 28 January 2000
Resolved 4 February 2000
Accommodation/Occupational Safety
Issued 27 January 2000
Resolved
VESSEL HAD SEVERE INFESTATION OF ROACHES IN GALLEY, CREW LOUNGE AREA, AND FOOD/PROVISION STORES AREAS. FUMIGATE EFFECTED AREAS PRIOR TO DEPARTURE FROM NEW YORK.
Condition: Unknown
Due 1 February 2000
Resolved 4 February 2000
Documentation
Issued 27 January 2000
No resolution recorded
OIL TRANSFER PROCEDURES NOT ON BOARD. DEVELOPED TEMPORARY PROCEDURES DURINGINSPECTION. PROVIDE OFFICIAL VERSION OF OIL TRANSFER PROCEDURES TO THE SATISFACTION OF USCG PRIOR TO 28FEB00
Condition: Unknown
Due 28 February 2000 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 27 January 2000
Resolved
RAW SEWAGE LEAKING FROM PIPING IN CREW'S HEAD A. PIPING FROM COMMODE HOLED.CLEAN AREA OF RAW SEWAGE, AND SECURE SPACE UNTIL PERMANENT REPAIRS HAVE BEEN MADE TO PIPING. MAKE PERMANENT REPAIRS PRIOR TO 01FEB00.
Condition: Unknown
Due 1 February 2000
Resolved 4 February 2000
Electrical
Issued 27 January 2000
Resolved
ELECTRICAL HAZARD AT CONDENSER IN FISH FREEZER. ELECTRICAL BOX MISSING, WITH OPEN ELECTRICAL WIRING SURROUNDED BY 4 INCHES OF ICE. SECURE POWER TO FREEZER, DEFROST, AND MAKE PERMANENT REPAIRS TO WIRING PRIOR TO 01FEB00.
Condition: Unknown
Due 1 February 2000
Resolved 4 February 2000
Lifesaving
Issued 12 August 1997
Resolved
PROVIDE A BOAT HOOK FOR STARBOARD LIFEBOAT PER SOLAS 60 REG III-11
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
REPLACE ALL HOLED 65 MM FIRE HOSES AND PROVIDE ONE SPARE PER SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
RENEW ALL DETERIORATED GASKETS IN ALL FIRE HOSE NOZZLES THROUGHOUT THE VESSEL. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
REPAIR THE EXHAUST LEAK FROM THE EMERGENCY FIRE PUMP. _x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
RENEW AS ORIGINAL ALL HOLED AND WASTED SECTIONS OF THE FIREMAIN AS ORIGINALAND HYDROSTATICALLY TEST TO THE SATISFACTION OF THE ATTENDING FLAG STATE REPRESENTATIVE AND COAST GUARD INSPECTOR. PER. SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
CONDUCT A SATISFACTORY FIRE DRILL TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR. SOLAS 74 (AMENDED) III-18.3
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Accommodation/Occupational Safety
Issued 12 August 1997
Resolved
PROVIDE A SUITABLE DOOR CLOSURE BETWEEN THE GALLEY AND THE OFFICERS MESSROOM AND PANTRY IN ACCORDANCE WITH THE VESSEL'S FIRE CONTROL PLAN _x001C_ SOLAS 60 II/36
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 12 August 1997
Resolved
FREE UP THE FROZEN FIRE HYDRANT ON THE PORT SIDE, UPPER DECK PER SOLAS 74 (AMENDED) II-2/11
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Accommodation/Occupational Safety
Issued 12 August 1997
Resolved
RENEW GASKET ON THE VENTILATION CLOSURE ON PORT SIDE, UPPER DECK PER SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Deck/Cargo
Issued 12 August 1997
Resolved
REMOVE ALL OILY SLUDGE FROM THE FUEL OIL PURIFIER CONTAINMENTS PER SOLAS 74(AMENDED) II-2/11
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Construction/Loadline
Issued 12 August 1997
Resolved
RENEW AS ORIGINAL THE WASTED DETERIORATED GENERATOR SEAWATER COOLING PIPINGIN WAY OF LOWER ENGINEROOM FLAT STARBOARD SIDE PER SOLAS 74 (AMENDED) I-11(a)
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997
Construction/Loadline
Issued 12 August 1997
Resolved
RENEW AS ORIGINAL HOLED BALLAST OVERBOARD DISCHARGE PIPING IN LOWER ENGINEROOM FLAT STARBOARD SIDE IN WAY OF TEMPORARY REPAIR. PER SOLAS 74 (AMENDED) 1-11(a)
Condition: Unknown
Due 14 August 1997
Resolved 20 August 1997