← All vessels
FIRSTEC
FIRSTEC is a 1977 freight ship. The Coast Guard has recorded 23 inspections since 1985, most recently in August 2002, along with 25 deficiencies and 3 operational controls.
Records from 1985 to 2002. Most recent: operational control imposed, 19 August 2002.
- Built
- 1977
- Last inspected
- 18 August 2002
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7601451 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRAF8
225734
Flag
HONG KONG
—
Maury page id
psix-225734
Inspections, by type
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it10914 - Regulatory (Subpart C or D), Net Ton
10914 - Convention (Subpart B), Net Ton
29554 - Dead Weight, Metric Ton
36856 - Displacement, Metric Ton
18328 - Regulatory (Subpart C or D), Gross Ton
18328 - Convention (Subpart B), Gross Ton
10914 - Convention (Subpart B), Net Ton
29554 - Dead Weight, Metric Ton
36856 - Displacement, Metric Ton
18328 - Regulatory (Subpart C or D), Gross Ton
18328 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
18 August 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1663161
7 June 2002
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1627831
30 May 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1623680
12 September 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 293701
20 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291291
11 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289023
7 June 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 278751
14 February 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 435253
6 December 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 435440
15 March 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426566
26 March 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 414021
17 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 405787
17 March 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 401509
4 August 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 393946
15 May 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 391249
14 May 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 391138
19 December 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 511736
23 March 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 710518
14 February 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 376519
15 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 494640
10 August 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 345267
9 April 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 342748
29 October 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 305027
Deficiency record · 25
Engineering › Sea-water System (primary cooling)
Issued 30 May 2002
Resolved
Soft patch has been installed and painted over on the main engine piston cooler endbell. SOLAS 74A I/11 LEGACY COMPONENT DESC: Piping
Operations/Management › Vessel Safety Management
Issued 30 May 2002
Resolved
Galley and food prep areas infested with roaches. Vessel to provide receipt of fumigation prior to resolution date. LEGACY COMPONENT DESC: Resources and Personnel
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
19 OF 21 WATER CLOSETS/TOILETS IN CREW ACCOMMODATION NOT PROVIDED WITH AMPLE FLUSHING WATER WITH INDEPENDENT CONTROL. REPAIR PRIOR TO DEPARTURE FROM PORT (ILO 147).
Engineering
Issued 20 June 2001
Resolved
PERFORM HYDROSTATIC TEST OF BUNKER PIPING AND MAINTAIN RECORDS AS REQUIRED BY 33 CFR 155.820(B) PRIOR TO BUNKERING/CONDUCTING MARINE OIL TRANSFERS IN U.S. WATERS (33 CFR 156).
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
REPAIR HANDLE AND LATCH ON NON-TIGHT DOOR IN AFTER STEERING COMPARTMENT TO ENGINE ROOM BY 22 JUNE 2001 (SOLAS 60 II/38).
Fire Fighting
Issued 20 June 2001
Resolved
CONDUCT ABANDON SHIP DRILLS IN ACCORDANCE WITH SOLAS III/19.3.3.1.9. CREW NOT FAMILIAR WITH USE OF RADIO LIFESAVING APPLIANCES. PROVE EVIDENCE OF PROPER TRAINING BY NEXT U.S. PORT (SOLAS 74A III/19).
Electrical
Issued 20 June 2001
Resolved
ELECTRICAL CONNECTION IN SWITCHBOARD, FORWARD HYDRAULIC ROOM UNSAFE. MAKE PROPER ELECTRICAL CONNECTION AND PROVIDE ELECTRICAL SAFETY MATT IN FRONT OFSWITCHBOARD BY 22 JUNE 2001 (SOLAS 60 II/27).
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
VENTILATORS TO ENGINE ROOM SEIZED AND UNABLE TO BE SECURED FROM OUTSIDE ENGINE ROOM. REPAIR AND DEMONSTRATE PROPER OPERATION TO SATISFACTION OF CLASS OR USCG INSPECTOR PRIOR TO DEPARTURE FROM PORT (SOLAS 60 II/47b)
Lifesaving
Issued 20 June 2001
Resolved
GRAB LINE ON LIFEBUOY, STARBOARD SIDE BOAT DECK, WASTED/ROTTED. REPLACE BY22 JUNE 2001 (SOLAS 74A III/20.2).
Fire Fighting
Issued 20 June 2001
Resolved
CO2 DISCHARGE PIPE #1 HOLD, PORT SIDE, BROKEN IN WAY OF ISOLATION VALVE ANDNOT PROPERLY SUPPORTED ON DECK. REPAIR TO SATISFACTION OF CLASS PRIOR TO DEPARTURE FROM PORT (SOLAS 60 II/58).
Accommodation/Occupational Safety
Issued 20 June 2001
Resolved
EXHAUST VENTILATION DUCTING IN GALLEY FOILED WITH EXCESSIVE GREASE. CLEAN BY 22 JUNE 2001 (SOLAS 60/34).
Lifesaving
Issued 7 June 2000
Resolved
PROVE PROPER FIRE & ABANDON SHIP DRILLS.
Lifesaving
Issued 14 February 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting
Issued 15 March 1999
Resolved
FIRE DOORS BETWEEN STEERING ROOM AND ENGINE ROOM INOPERABLE_x001C_ _x001C_ SOLAS 74 UNAMENDED REG II-2/51
Navigation
Issued 17 March 1997
Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE CHARTS USED BY THE VSL TO SAIL FROM CAPE HENLOPEN TO GLOUCESTER NJ WHERE NOT CURRENTLY CURRECTED
Construction/Loadline
Issued 14 May 1996
Resolved
MAKE PERMANENT REPAIRS TO HANDRAIL ON STARBOARD SIDE FORCASTLE NO LATER THAN 16JUN96 AND TO THE SATISFACTION OF AN ABS CLASSIFICATION SURVEYOR.
Lifesaving
Issued 14 May 1996
Resolved
REPLACE BATTERIES IN ALL LIFE JACKET LIGHTS NO LATER THAN 16JUN96 AND TO THE SATISFACTION OF THE ABS CLASSIFICATION SURVEYOR.
Construction/Loadline
Issued 14 May 1996
Resolved
PROVIDE NUTS AND BOLTS FOR ALL BALLAST TANK DECK COVER NO LATER THAN 16JUN96 AND TO THE SATISFACTION OF AN ABS CLASSIFICATION SURVEYOR.
Documentation
Issued 14 May 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 14 May 1996
Resolved
REPAIR RE-CIRCULATING SOLENOID ON THE OILY WATER SEPARATOR NO LATER THAN 16JUN96 TO THE SATISFACTION OF AN ABS CLASSIFICATION SURVEYOR.
Lifesaving
Issued 14 May 1996
Resolved
MAKE PERMANENT REPAIRS TO THE GRAB RAIL ON PORT LIFEBOAT NO LATER THAN 16JUN96 TO THE SATISFACTION OF AN ABS CLASSIFICATION SURVEYOR.
Lifesaving
Issued 14 May 1996
Resolved
MAKE REPAIRS TO 3 SHEAVES ON STARBOARD LIFEBOAT DAVIT ARM (FORWARD ARM) NO LATER THAN 16JUN96 AND TO THE SATISFACTION OF AN ABS CLASSIFICATION SURVEYOR.
Navigation
Issued 14 February 1995
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD.
Navigation
Issued 9 April 1991
Resolved
VESSEL DID NOT HAVE A COAST GUARD LIGHT LIST ONBOARD 33 CFR 164.33 (ii)_x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 9 April 1991
Resolved
VESSEL FAILED TO HAVE U.S. COAST PILOT ONBOARD 33 CFR 164.33 (i)_x001C_ _x001C_ _x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.