MAURY USCG vessel records Sign in
← All vessels

SEA CONCERT

SEA CONCERT is a 1976 freight ship. The Coast Guard has recorded 16 inspections since 1985, most recently in November 2001, along with 86 deficiencies and 1 operational control.

Records from 1985 to 2001. Most recent: inspection, 29 November 2001.

Built
1976
Last inspected
29 November 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7602986 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225773
Flag
PANAMA
—
Maury page id
psix-225773

Inspections, by type

…with no type recorded16
Years with a record 13 calendar years (1985–2001)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11043 - Regulatory (Subpart C or D), Net Ton
33177 - Dead Weight, Ton
20849 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

29 November 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 652137
5 November 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 294750
11 May 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 277496
7 May 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 18715
18 February 1999 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 425477
7 December 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 423231
18 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 377350
5 April 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 357321
6 April 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349988
19 December 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340745
25 January 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 328142
13 January 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 320740
12 January 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313722
7 July 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 496458
5 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306226
4 September 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 504470

Deficiency record · 86

Engineering
Issued 5 November 2001 Resolved
REPAIR AUXILIARY SALTWATER PIPING PORT SIDE ENGINE ROOM ABOVE OWS PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Engineering
Issued 5 November 2001 Resolved
PROVIDE CLASS APPROVAL OR REPAIR FOR CEMENT BOX PATCH FWD ENGINE ROOM #4 BILGE TANK VALVE WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Fire Fighting
Issued 5 November 2001 Resolved
REPAIR SUCTION PIPING MANIFOLD FOR FIRE PUMPS PORT ENGINE ROOM. PIPING WASTED AND PLUGGED WITH WOOD. PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Electrical
Issued 5 November 2001 Resolved
REPAIR WASTED SALTWATER LINE TO #1 GENERATOR TURBO CHARGER PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR HOLE IN DECK IWO WATERTIGHT DOOR AIR CONDITIONING SPACE OFFICERS DECK PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED DECK IWO FIRE MAIN VALVE AND LADDER PORT AFT OFFICERS DECK PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
PROVIDE CLASS APPROVAL ON NUMEROUS DOUBLERS ABOUT THE DECK PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Fire Fighting
Issued 5 November 2001 Resolved
CONDUCT ACCEPTABLE FIRE DRILL PRIOR TO DEPARTURE.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Documentation
Issued 5 November 2001 Resolved
COMPANY/VESSEL HAS FAILED TO IMPLEMENT THE REQUIRMENTS OF SOLAS CH.IX ISM CODE.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED TOE BRACKET STBD SIDE FWD OF #2 CARGO HOLD PRIOR TO DEPARTURETO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Electrical
Issued 5 November 2001 Resolved
PROVIDE EXPLOSION PROOF LIGHT COVERS FOR 2 LIGHTS IN FOREPEAK WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED PORT SIDE AFT BRACKET OF CARGO HOLD #1 PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED PORT SIDE FRAMES NEAR HOLD #1 PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Deck/Cargo
Issued 5 November 2001 Resolved
REPAIR HYDRAULIC OIL PIPE LEAK PORT SIDE OF #2 HOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR #3 CARGO HOLD COMBING BRACKET PORT SIDE FWD AT DECK CONNECTION PRIORTO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED LADDER FWD OF #4 CARGO HOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED HOLD #4 PORT SIDE AFT BRACKET PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR ALL WASTED BRACKETS FWD OF #5 CARGO HOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED FRAMING PORT SIDE ENGINE ROOM IWO SANITARY PUMP PIPING PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR STBD SIDE COMBING RAIL AT #3 CARGO HOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Engineering
Issued 5 November 2001 Resolved
REPAIR AUXILIARY SALTWATER PIPING PORT SIDE ENGINE ROOM ABOVE BILGE PUMP MANIFOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR SOFT PATCH BILGE SUCTION LINE FWD ENGINE ROOM IWO FUEL TANK #5 SUCTION PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Electrical
Issued 5 November 2001 Resolved
INSTALL GMDSS EMERGENCY BATTERIES IN TRAY WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Accommodation/Occupational Safety
Issued 5 November 2001 Resolved
REPAIR WASTED HANDRAILS THROUGHOUT PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Deck/Cargo
Issued 5 November 2001 Resolved
PROVIDE CONTAINMENT BOX FOR LUBE OIL AND GENERATOR OIL CONNECTION ON BOTH PORT AND STBD SIDES WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Deck/Cargo
Issued 5 November 2001 Resolved
REPAIR VENT TRUNK AT CARGO HOLD #4 IWO #4 MAST HOUSE PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Electrical
Issued 5 November 2001 Resolved
PROVIDE 2 EXPLOSION PROOF LIGHT COVERS IN MAST HOUSE #4 WITHIN 30 DAYS.
Condition: Unknown
Due 14 December 2001
Resolved 27 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR HOLE IN CONTAINMENT ON TOP OF MAST HOUSE #2 WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR CEMENT PATCH IN STORE ROOM IWO #4 MAST HOUSE PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Fire Fighting
Issued 5 November 2001 Resolved
REPAIR HOLED CO2 SYSTEM PIPE AT #4 CARGO HOLD(FIXED FIRE FIGHTING) PRIOR TODEPARTURE, TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED COMBING ON #3 CARGO HATCH COVER PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR HOLED DECK IN BETWEEN FWD MAST HOUSE #2 AND #3 CARGO HOLD PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Lifesaving
Issued 5 November 2001 Resolved
RESTOW OXYGEN TANKS IN RACKS OUTSIDE OF MAST HOUSE #2 PRIOR TO DEPARTURE TOSATISFACTION OF CLASS
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Deck/Cargo
Issued 5 November 2001 Resolved
REPAIR LEAK TO HYDRAULIC LINE TO #5 CHAIN DRIVE MOTOR PRIOR TO DEPARTURE TOSATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR CEMENT PATCH AROUND PIPING IN DECK STBD SIDE TALLY ROOM PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR HOLE IN STBD SIDE CORNER OF TALLY ROOM PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR FLATBAR TO #1 CARGO HOLD FAN ROOM DOOR WITHIN 30 DAYS.
Condition: Unknown
Due 14 December 2001
Resolved 27 November 2001
Deck/Cargo
Issued 5 November 2001 Resolved
PROVIDE CONTAINMENT FOR WASTE OIL TRANSFER ON STBD SIDE WITHIN 30 DAYS.
Condition: Unknown
Due 14 November 2001
Resolved 27 November 2001
Construction/Loadline
Issued 5 November 2001 Resolved
REPAIR WASTED AFT PORT CORNER AT GALLEY BULKHEAD PRIOR TO DEPARTURE, TO SATISFACTION OF CLASS.
Condition: Unknown
Due 15 November 2001
Resolved 21 November 2001
Deck/Cargo
Issued 11 May 2000 Resolved
Perform permanent repairs at pipes where leaking oil at: #5 hydraulic motorto hatch cover, oil return line between hatch #1 & #2, stbd of #5 hatch, stbd of #3 hatch, #3 hydraulic motor to hatch cover, fwd port of #3 hatch and port side of forecastle space where deck is oil flooded, SOLAS 60 I/11.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Engineering
Issued 11 May 2000 Resolved
Provide complete oil transfer procedures. 33 CFR 155.720. Complete prior tonext U.S. port after sailing foreign.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Lifesaving
Issued 11 May 2000 Resolved
Update crew familiarization training for new crew members. STCW A-VI/1. Correct prior to next U. S. port after sailing foreign.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Fire Fighting
Issued 11 May 2000 Resolved
Crew is to perform fire drill to the satisfaction of marine inspector priorto departure.
Condition: Unknown
Due 12 May 2000
Resolved 23 May 2000
Lifesaving
Issued 11 May 2000 Resolved
Remove lashings from liferafts and properly rig hydrostatic release, SOLAS 74 amd I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Provide fire nozzles suitable for spraying water on oil at lower engine room hydrants and at steering room hydrant, SOLAS 60 II-E/65.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Install insulation as original on exhaust pipe from emergency fire pump, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Engineering
Issued 11 May 2000 Resolved
Install cotter/split key on governor linkage at stbd diesel generator._x001C_ SOLAS 60 I/11
Condition: Unknown
Due 18 May 2000
Resolved 23 May 2000
Electrical
Issued 11 May 2000 Resolved
Provide proper size operating handle for the hand emergency start air compressor. SOLAS 60 I/11
Condition: Unknown
Due 18 May 2000
Resolved 23 May 2000
Deck/Cargo
Issued 11 May 2000 Resolved
Provide mechanical plugs for containment drain holes, 33 CFR 156.120.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Deck/Cargo
Issued 11 May 2000 Resolved
Perform permanent repairs to control flooding in tally room, stbd forward of house main deck, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Deck/Cargo
Issued 11 May 2000 Resolved
Renew stbd anchor brake lining, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Lifesaving
Issued 11 May 2000 Resolved
Provide life jackets in a marked location at forecastle, SOLAS 74 amd III/7.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Repair paint locker sprinkler valve where leaking fire main water into space, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Construction/Loadline
Issued 11 May 2000 Resolved
Repair hole in steering room bulkhead forward where wire was removed, SOLAS60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Permanently repair fire main where soft patched port side of #1 hatch, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Fill all empty SCBA bottles and move one half of the SCBA spare bottles to the bridge as per fire plan.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Make the three fire screen doors to engine room self closing as original, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Fabricate and install hand guard at emergency fire pump, ILO 147.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Navigation
Issued 11 May 2000 Resolved
Prove proper operation of port pilot pump to steering gear where grinding/chattering noise evident during operational test, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Construction/Loadline
Issued 11 May 2000 Resolved
Perform permanent repair to forward bulkhead of steering room where fractured approximately 4" long located just forward of emergency fire pumpfuel tank, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Lifesaving
Issued 11 May 2000 Resolved
Provide operable life jacket lights throughout vessel, SOLAS 74 amd III/27.2.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Construction/Loadline
Issued 11 May 2000 Resolved
Perform permanent repair to stbd sea chest vent spool piece where holed andto port side sea chest vent where corroded, SOLAS 60 I/11.
Condition: Unknown
Due 11 June 2000
Resolved 23 May 2000
Fire Fighting
Issued 11 May 2000 Resolved
Provide report from class approving arrangement of CO2 pipes where half of the pipes are now blanked off and the cargo holds only have 2 nozzles each.
Condition: Unknown
Due 11 June 2000
Resolved 18 May 2000
Lifesaving
Issued 7 December 1998 Resolved
BRIDGE WING LIFEBOUYS NOT OF SIGNIFICANT WEIGTH TO DEPLOY THE SELF- ACTIVATING SMOKE. REPLACE AND INSTALL TO THE SATISFICATION OF CLASS.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Fire Fighting
Issued 7 December 1998 Resolved
EMERGENCY FIRE PUMP WOULD NOT START.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 7 December 1998 Resolved
GRAB LINES FOR PORT SIDE LIFEBOAT BROKEN. MAKE PERMANENT AND PROPER REPAIRSTO THE SATISFICATION OF CLASS.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Lifesaving
Issued 7 December 1998 Resolved
ATTACH CRUTCHES TO BOTH PORT AND STARBOARD LIFEBOATS WITH LANYARD OR CHAIN.BOTH LIFEBOATS HAD CRUTCHES, BUT WERE LOCATED IN A BUCKET AND DIFFICULT TO GET AT. INSTALL TO THE SATISFICATION OF CLASS
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Deck/Cargo
Issued 18 April 1995 Resolved
Permanently repair the oil leak on the port anchor windlass assembly, priorto return to a U. S. port, per 33 CFR 151.10(b)
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Deck/Cargo
Issued 18 April 1995 Resolved
Make permanent repairs to the hatch cover coaming structure prior to next U. S. voyage, per ICLL Chpt II Reg 15. Reference PSNS for detials.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Engineering
Issued 18 April 1995 Resolved
Replace the missing belt drive guards on the pumps in the lower level engineroom (3), prior to departure, per SOLAS Chpt II-1 Reg 26(1)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 18 April 1995 Resolved
Permanently repair the broken access plates (all) on the forcastle and center deck houses. (The access plates are used for cable passage) Correct prior to departure, per ICLL Chpt II Reg 12(1)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 18 April 1995 Resolved
Clean the excessive oil from: a) engineroom bilges, b) about lube oil purifiers, c) M/E l/o pumps, d) fuel oil xfer pump, e) full oil buckets in the stbd, lower level fwd corner, f) on decks in the forecastle space, prior to departure, per SOLAS Chpt II-2 Reg 2
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Remove all paint from the forecastle space and steering gear space and place in the approved paint locker, prior to departure, per SOLAS Chpt II-2Reg 18(7).
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Replace missing closure devices on the engineroom and steering gear room fire doors, prior to departure, per SOLAS Chpt II-2 Reg 45(3)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 18 April 1995 Resolved
Permanently repair the exhaust leak on the stbd lifeboat engine, prior to departure, per SOLAS Chpt III Reg 41(6)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Replace the unreadable fire control plan on the main deck, prior to departure, per SOLAS Chpt II-2 Reg 20(1)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 18 April 1995 Resolved
Prove proper operation of the port life boat engine. The engine runs, but there is a bad vibration problem while running the engine forward and reverse. Correct prior to departure, per SOLAS Chpt III Reg 41(6.1)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Prove proper operation of the emergency fire pump. The priming pump has been disabled and the main pump can not take a suction. Test with 2 hoses.Correct prior to depature, per SOLAS Chpt II-2 Reg 4(3.3.2)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 18 April 1995 Resolved
Permanently repair the cargo hatch rotary drivers. They are badly leaking oil. Empty buckets and clean decks about the gear, prior to departure, per33 CFR 151.10(b)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 18 April 1995 Resolved
Make permanent repairs to the patched/wasted hydraulic line on stbd side of#4 hatch, prior to departure, per 33 CFR 151.10(b)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Deck/Cargo
Issued 18 April 1995 Resolved
Repair the hatch covers where wasted through (as per PSNS). Provide a Class report on the remaining 7 locations (at rubber stops) as they appear badly wasted, prior to departure, per ICLL Chpt II Reg 15
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Construction/Loadline
Issued 18 April 1995 Resolved
Several topside ballast tank manhole covers were leaking overflowing ballast water on the main deck. Provide a class report on the watertight integrity of these manhole covers, prior to departure, per ICLL Chpt II
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Engineering
Issued 18 April 1995 Resolved
Make permanent repairs to the port main sea suction line (inboard of sea valve) where wasted, patched and leaking, prior to departure, per SOLAS Chpt II-2 Reg 26(1)
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 18 April 1995 Resolved
Make permanent repairs to the anchor chain wash lines where wasted, prior to next U. S. voyage, per SOLAS Chpt II-2 Reg 4
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Navigation
Issued 5 April 1993 Resolved
CHARTS 18521, 18523 AND 18524 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 6 April 1993
Resolved 9 April 1993
Navigation
Issued 5 January 1986 Resolved
USCG LIGHT LIST VOL.III WAS NOT CORRECTED UP TO DATE. 1985 TIDAL CURRENT TABLES WERE NOT ON BOARD.
Condition: Unknown
Due 5 January 1986
Resolved 5 January 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.