← All vessels
HISARONU-M
HISARONU-M is a 2001 public freight. The Coast Guard has recorded 17 inspections since 2002, most recently in April 2025, along with 21 deficiencies — 3 with no resolution recorded — and 3 operational controls.
Records from 2002 to 2025. Most recent: inspection, 15 April 2025.
- Built
- 2001
- Last inspected
- 15 April 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 3 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9225524 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3E2820
22578
Flag
PANAMA
—
Maury page id
psix-22578
Inspections, by type
…with no type recorded4
…past their stated due date1
Years with a record
6 calendar years (2002–2025)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28085 - Convention (Subpart B), Gross Ton
16065 - Convention (Subpart B), Net Ton
48893 - Dead Weight, Ton
57340 - Displacement, Ton
16065 - Convention (Subpart B), Net Ton
48893 - Dead Weight, Ton
57340 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
15 April 2025
Appeal
Administrative · Commandant (CG-CVC) · Activity 8131672
21 March 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8100276
18 March 2025
PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8095337
27 February 2025
In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8085831
27 February 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8085956
27 February 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8089440
20 February 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8080819
13 February 2025
PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8078984
9 February 2025
Deficiency Check · ISM Exam · PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8076869
28 December 2022
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7613707
22 December 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7612092
9 March 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3690361
13 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3146764
9 February 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144838
30 January 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3128544
5 December 2003
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1955189
7 September 2002
Ballast Water Examination · Annual Inspection · Security Inspection · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1672158
Deficiency record · 21
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 March 2025
Resolved
The engine shall...be provided. The engine starting systems and starting Aids shall start the engine at an ambient temperature of -15C within 2 minutes of commencing the start procedure. PSCO observed that rescue boat did not start. After replacing batteries, PSCO observed it took 45 minutes to start engine. 74SOLAS(20)III/34, LSA Code 4.4.6.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2025
Resolved
Not less than one half of the total number of lifeboats shall be provided with lifebuoy self-igniting lights. PSCO observed 05 self-igniting lights of 12 lifebuoys. 74SOLAS(20)III/7.1.3
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 February 2025
No resolution recorded
NOT LESS THAN ONE HALF OF THE TOTAL NUMBER OF LIFEBUOYS SHALL BE PROVIDED WITH LIFE BUOY SELF-IGNITING LIGHTS COMPLYING WITH THE REQUIREMENTS OF PARAGRAPGH 2.1.2 OF THE CODE. PSCO OBSERVED THREE (03) INOPERABLE SELF-IGNITING LIGHTS ON THE FOLLOWING LIFEBUOYS: PORT LIFEBOAT, MIDSHIP PORT, AND STARBOARD.
74 SOLAS (20)III/7.1.3
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 13 February 2025
Resolved
All ships engaged on international voyages shall keep on board a record of navigational activities and incidents which are of importance to safety of navigation and which contains sufficient detail to restore a complete record of the voyage. PSCO observed that no entries had been made in the ship's logbook since 09FEB2025, a period which includes a voyage from the previous port of call.
74SOLAS(20) V/28.1
15bc
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 13 February 2025
No resolution recorded
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be installed and protected as to reduce to a minimum any danger to persons on board, with due regard being paid to... other hazards. PSCO observed a significant amount of foul-smelling water pooled at the entrance to the CO2 room, which could not be explained by the ship's crew but was identified as grey water by the Chief Engineer.
74SOLAS(04) II-1/26.1
40ac
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 February 2025
No resolution recorded
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the Administration. PSCO observed a significant soft patch on the cable run, port side, in the vicinity of cargo hold #4.
74SOLAS(20) I/11(b)
40ac
09 - Working and Living Conditions › 091 - Living Conditions › Cold room
Issued 13 February 2025
Resolved
There is evidence that the ship does not conform to the standards of provided for in Article of the Convention No. 68. PSCO observered excess ice build-up on deck in freezer space directly below the evaporator.
ILO 147, pg. 31, 1(c)
46 USC 70002
10c
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 February 2025
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43 as appropriate. PSCO observed the port side emergency battery space and starboard lifeboat deck spot/search light were both inoperable.
74SOLAS(20) III/11.4
10c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 February 2025
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE SHIP
IS MANTAINED IN ACCORDANCE WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. THE VESSEL MANAGEMENT SYSTEM STATES THAT THE DEFECT IN CRITICAL EQUIPMENT SYSTEMS MUST ALWAYS BE REPORTED IN ACCORDANCE WITH PROCEDURES AND BE HANDLED WITH PRIORITY AMONG PENDING ITEMS FOR SCHEDULED AND UNSCHEDULED MAINTENANCE. THE VESSEL'S ENGINEERING CREW WAS UNABLE TO PROVIDE ANY DOCUMENTATION AS REQUIRED IN THE VESSEL'S SMS FOR ANY DEFECTIVE ITEMS. DEFICIENCIES #3 - #9-PROVIDE EVIDENCE OF SERIOUS LACK OF EFFECTIVENESS OF PLANNED MAINTENANCE SYSTEM AND REQUIRED ROUTING INSPECTION/ROUNDS BY THE SHIP'S CREW. DUE TO THE OBJECTIVE EVIDENCE INT HE ABOVE DEFICIENCIES, THE VESSEL IS NOT IN SUSBTANTIAL COMPLIANCE WITH RELEVANT CONVENTIONS. THE CAPTAIN OF THE PORT QUESTIONS THE OVERALL IMPLEMENTATION OF THE VESSEL'S SMS UNDER THE ISM CODE. AN EXTERNAL AUDIT CONDUCTED BY THE FLAG OR RO IS REQUIRED TO DETERMINE WHETHER THE SHIP IS OPERATING IN ACCORDANCE TO THE ISM CODE. PROVIDE A COPY OF THE COMPLETED AUDIT REPORT TO THE USCG PRIOR TO THE DEPARTURE FROM PORT.
74SOLAS (20) IX/3.1
ISM CODE 10.1
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 February 2025
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE.VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED A SUBSTANTIAL LEAK ON THE MDE SALT WATER COOLING PUMP.
74 SOLAS (04) II-1 / 26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 February 2025
Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRAGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE AMOUNT OF OILY-WATER MIXTURE IN THE BILGE, EXCESSIVE OIL ACCUMULATION, OIL RAGS AND EXCESSIVE TRASH SCATTERED THROUGHOUT THE ENGINE ROOM.
74 SOLAS (01) II-2 / 15.2
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 February 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 9 February 2025
Resolved
PERSONNEL RESPONSIBLE FOR THE OPERATION OF AN INCINERATOR INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS IN REG. 16.8 ACCORDANCE WITH THE REQUIREMENTS OF PARAGRAPH 6.1 OF THIS REGULATION SHALL BE TRAINED TO IMPLEMENT THE GUIDANCE PROVIDED IN THE MANUFACTURER'S OPERATING MANUAL AS REQUIRED BY PARAGRAPH 7 OF THIS REGULATION. PSCO OBSERVED THE Incinerator's REFRACTORY WAS CRACKED ANO DAMAGED AND RESIDUAL ASH LEFT IN INCINERATOR BUT NO RECORD OF INCINERATOR USAGE.
MARPOL ANNEX I REG. 16.8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 February 2025
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUN ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED A WRENCH ZIP TIED TO THE VALVE THAT ALLOWS WATER IN THE PURIFIER HOLDING THE VALVE OPEN.
74 SOLAS (04) II-1 / 26.1
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 February 2025
Resolved
EFFICIENT GUARD RAILS OR BULWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. PSCO OBSERVED DECK RAILING ON PORT AND STARBOARD SIDE FRACTURED AND DETERIORATED BEYOND USE.
ICLL I/25.2
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 February 2025
Resolved
A FIREMAN'S OUTFIT SHALL CONSIST OF PERSONAL EQUIPMENT COMPRISING AN ELECTRIC SAFETY LAMP (HAND LANTERN) OF AN APPROVED TYPE. PSCO OBSERVED 02 INOPERABLE FIREMAN'S LANTERNS.
74 SOLAS (01) II-2 / 17.1.1.4
Navigation › Piloting/Steering
Issued 5 December 2003
Resolved
Provide copy of U.S. inland navigation rules. Must be on board prior to departing from the port of Longview, WA 33 cfr 88.05 LEGACY COMPONENT DESC: Inland Navigation Rules
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 December 2003
Resolved
Provide copy of U.S. navigation regulations (33 CFR 164.25) referenced in vessel operations manual. Q-300 ISM Code
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 December 2003
Resolved
Provide replacement medications in vessel's hospital space for all that are currently expired. ILO 147
Documentation › Logs/Records › Oil Record Book
Issued 5 December 2003
Resolved
Commence making proper and complete entries in the Oil Record Book as specified in MARPOL annex I reg 20 para 2. That each operation must be individually entered.
Documentation › Certificates/Documents › IOPP Certificate
Issued 5 December 2003
Resolved
Have the waste oil tank, capacity .4m^3, endorsed on table 3.1 of the vessel's IOPP. MARPOL annex I/7
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.