← All vessels
SIFNOS SKY
SIFNOS SKY is a 1977 freight ship. The Coast Guard has recorded 30 inspections since 1984, most recently in July 2005, along with 35 deficiencies and 3 operational controls.
Records from 1984 to 2005. Most recent: inspection, 7 July 2005.
- Built
- 1977
- Last inspected
- 7 July 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7604879 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HOT6
225797
Flag
LIBERIA
—
Maury page id
psix-225797
Inspections, by type
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it7486 - Convention (Subpart B), Net Ton
26438 - Dead Weight, Ton
33645 - Displacement, Ton
15848 - Convention (Subpart B), Gross Ton
26438 - Dead Weight, Ton
33645 - Displacement, Ton
15848 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
7 July 2005
ISPS III Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2418045
24 March 2005
ISPS II Exam · PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2318827
27 May 2004
Re-Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2079544
22 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2050446
5 February 2004
Deficiency Check · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2001394
24 September 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1912137
19 February 2002
In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1487529
30 January 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1481422
24 February 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274948
19 July 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 405872
17 October 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 396399
16 June 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 392289
26 December 1995
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 386149
19 October 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 383934
19 October 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1190778
27 May 1994
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 367109
27 May 1994
Passenger/Freight Vessel Examination · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1385241
7 April 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 357416
23 September 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 353303
30 April 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350666
6 September 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345753
14 January 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 516765
30 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338543
20 July 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 331427
7 June 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323766
10 June 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 316684
14 November 1986
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 312691
22 June 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 467484
19 November 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 305447
14 December 1984
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 299306
Deficiency record · 35
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 24 March 2005
Resolved
MISSING LIGHT COVERS IN VARIOUS SPACES THROUGHOUT SHIP
Lifesaving › Launching Appliances › Falls
Issued 24 March 2005
Resolved
FALLS HAVE NOT BEEN REPLACED SINCE 15 MAY 99 ON NUMBER 2 LIFE BOAT
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 24 March 2005
Resolved
RUDDER BECAME DAMAGED WHEN LOWERING BOAT CAUSEING RUDDER TO BECOME UNHINGED
Construction/Loadline › Structures › Door
Issued 24 March 2005
Resolved
DOORS STBD SIDE FWD (PAINT LOCKER) INOP
Construction/Loadline › Markings › Load Line Mark
Issued 24 March 2005
Resolved
DECK MARK ON LOADLINE IS NON-EXISTANT
Fire Fighting › Firemans Outfit
Issued 24 September 2003
Resolved
Protective coating on secondary fireman's outfit has worn off. Provide receipt for purchase of replacement suit including gloves and helmet to USCG prior to 28 September 2003. LEGACY COMPONENT DESC: Protective Clothing
Engineering › Steering Gear System
Issued 24 September 2003
Resolved
No. 2 steering pump telemotor pilot cylinder has noteworthy leaks. LEGACY COMPONENT DESC: Tele-motor
Engineering › Steering Gear System
Issued 30 January 2002
Resolved
NUMBER TWO STEERING GEAR PUMP COVER IS WASTED. REPLACE WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Pump
Engineering › Steering Gear System
Issued 30 January 2002
Resolved
NUMBER ONE STEERING AUXILIARY PUMP GUARD WASTED. REPLACE WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Pump
Electrical › Electric Generation Source (service)
Issued 30 January 2002
Resolved
PORT SIDE HIGH VOLTAGE SCREEN ON BRIDGE DECK WASTED. REPLACE/REMOVE WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Construction/Loadline › Structures
Issued 30 January 2002
Resolved
NUMBER TWO STARBOARD SIDE WING BALLST TANK COVER WASTED. REPLACED WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Manhole
Electrical › Electrical Distribution System (service)
Issued 30 January 2002
Resolved
ELECTRICAL WIRES IN LAUNDRY ROOM UNPROTECTED. REMOVE/REPAIR WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Cable
Lifesaving › Launching Appliances
Issued 30 January 2002
Resolved
LIMIT SWITCH ON STABOARD SIDE LIFEBOAT DOES NOT WORK PROPERLY. ENSURE LIMIT SWITCH IS ADJUSTED/REPAIR TO PROPER WORKING ORDER WITHIN 30 DAYS OF ISSUED DATE. LEGACY COMPONENT DESC: Davit
Fire Fighting
Issued 24 February 2000
Resolved
IAW SOLAS 74/78 ch. III reg. 18.3 crew was unable to peform a satisfactory fire.
Lifesaving
Issued 24 February 2000
Resolved
IAW SOLAS 74/78 ch. III reg. 41 8.12 10 rations on starboard lifeboat were either bad or missing.
Lifesaving
Issued 19 July 1997
Resolved
Limit switch for starboard lifeboat inoperative. Repair to satisfaction ofclassification society._x001C_ SOLAS 60 III/36(k)
Lifesaving
Issued 17 October 1996
Resolved
The crew was unable to demonstrate a satisfactory lifeboat drill. There wasno muster taken. Thew crew was not familiar with th process fo lowering theboat. The lifeboat's tiller was broken whil the boat was being lowered to the embarkation deck.
Fire Fighting
Issued 16 June 1996
Resolved
Make proper repairs/maintenance to all fireplugs throughout the vessel. Note: All external fireplugs leaked water when firemain was charged/testedduring 16JUN96 boarding.
Fire Fighting
Issued 16 June 1996
Resolved
Remove softpatch and make proper repairs to leaking firemain riser. Section of firemain is located inside the engineroom near the bulkhead. This riser feeds # 4 fire station which is located in a passageway next to the entrance of the engineroom.
Accommodation/Occupational Safety
Issued 19 October 1995
Resolved
Replace the gaskets in the fresh water maker so that Ram Neck tape is not needed to maintain a vacuum. Renew all wasted piping associated with the system. Complete by the next drydocking in July 1996._x001C_ SOLAS II-2/26.1
Engineering
Issued 19 October 1995
Resolved
Make permanent repairs to the wasted engineroom piping at the next drydocking (July 1996). See PSNS for detailed locations._x001C_ _x001C_ SOLAS II-2/26.1
Electrical
Issued 19 October 1995
Resolved
Remove all paint from the engineroom stores area place in the paint locker prior to departure._x001C_ _x001C_ SOLAS II-1/45.10
Lifesaving
Issued 19 October 1995
Resolved
The fuel tank in the stbd lifeboat needs to be renewed or properly repairedprior to departure._x001C_ _x001C_ SOLAS III/41.6.1
Lifesaving
Issued 19 October 1995
Resolved
The gear in the stbd lifeboat needs to be restowed out of the passenger compartments (i.e. in bow/stern or under seats) prior to departure._x001C_ _x001C_ SOLAS III/41.8
Lifesaving
Issued 19 October 1995
Resolved
The tricing pendants on the stbd lifeboat are too long. The boat rests about 1 foot below the embarkation deck. Complete prior to departure._x001C_ _x001C_ SOLAS III/48.1
Lifesaving
Issued 19 October 1995
Resolved
Renew the wooden foundation about the stbd lifeboat that supports the grab lines about the boat where wasted out & no longer supporting. Complete prior to departure._x001C_ SOLAS III/41.7.3
Electrical
Issued 19 October 1995
Resolved
Replace the missing guard on the explosion proof light in the fwd paint locker prior to return to a U. S. port._x001C_ _x001C_ SOLAS II-1/45.10
Lifesaving
Issued 19 October 1995
Resolved
Provide an additional lifejacket (2 total) in the engine control room priorto departure._x001C_ _x001C_ SOLAS III/7.2.1
Lifesaving
Issued 19 October 1995
Resolved
Clean the excessive oil from about the fuel / oil pruifiers prior to departure._x001C_ _x001C_ SOLAS II-2/2
Fire Fighting
Issued 19 October 1995
Resolved
Remove the hold back hooks from both fire doors to the steering gear / emergency fire pump room prior to departure._x001C_ _x001C_ SOLAS II-2/45.3
Lifesaving
Issued 19 October 1995
Resolved
Repair the wasted rottmer releasing gear in the stbd lifeboat prior to departure._x001C_ _x001C_ SOLAS III/41.7.6
Lifesaving
Issued 19 October 1995
Resolved
Repair the wasted exhaust line in the stbd lifeboat prior to departure._x001C_ _x001C_ _x001C_ SOLAS III/41.6.1_x001C_
Lifesaving
Issued 19 October 1995
Resolved
Free up the frozen locking arm arrangements on the stbd lifeboat prior to departure. Crew needed to use a fire axe to assist in lowering the lockingarm._x001C_ SOLAS III/48.1
Accommodation/Occupational Safety
Issued 27 May 1994
Resolved
REMOVE WOODEN STRUCTURE ON AFTERDECK OR PROVIDE SATISFACTORY HOME ADMINISTRATION EXEMPTION FROM SOLAS CHAPTER II-2 REGULATION 42.1 PRIOR TO ARRIVAL IN THE NEXT U.S. PORT OF CALL.
Engineering
Issued 27 May 1994
Resolved
MAKE SATISFACTORY PERMANENT REPAIRS TO THE SALT WATER COOLING SUPPLY PIPINGTO THE LUBE OIL HEAT EXCHANGER IN WAY OF THE NUMEROUS SOFT PATCHES TO THIS PIPING PER SOLAS CHAPTER I REGULATION 11(A) PRIOR TO DEPARTING THE PORT OF TOWNSEND, WASHINGTON.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.