Records from 2001 to 2024. Most recent: inspection, 23 March 2024.
Inspection history · 31
23 March 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7882870
5 February 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7853835
5 February 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7868891
31 January 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7858619
24 January 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7860893
23 April 2023
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7672947
21 March 2022
COC-CHEM Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7414374
6 March 2019
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6637193
15 February 2019
ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6626301
30 November 2017
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6310354
26 July 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3546003
26 July 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3548384
21 March 2009
ISPS II Exam · COC-CHEM Annual
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3431411
27 September 2008
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3319293
21 March 2008
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3169127
11 February 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2290747
24 January 2005
PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2279859
16 December 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2260761
15 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2261130
15 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2261457
4 October 2004
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2212994
30 September 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2209594
21 September 2004
COC-CHEM Renew
Type not classified · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2200808
28 June 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2114217
25 June 2004
NPV Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2110831
1 March 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2016716
20 February 2004
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2009745
6 February 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1744084
4 February 2003
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1744123
19 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288237
19 March 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1061231
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 February 2019
Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical, and electrcial requirements of a classification society which is recognized by the administration in accordance with the provisions of regulation XI/1. During hull examination, observed considerable damage to the port side hull near the water line.
74SOLAS(04) Chapter II-1, Reg 3-1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 February 2019
Resolved 6 March 2019
Resolution: Received Class Report clearing Deficiency
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 28 July 2009
Resolved
The connections to the excitation voltage controller module were loose, causing loss of propulsion.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 28 July 2009
Resolution: Received and Approved class report from American Bureau [name withheld] attesting to the controller modules proper repair.
Deck/Cargo › Cargo Heating › General
Issued 21 March 2008
Resolved
Port State Officer's found a soft patch on a steam line located on the main deck at cargo hold 2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2008
Resolution: Visual inspection. Cleared without class report.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 March 2008
Resolved
Several brackets to the seawater flush line on the main deck were broken
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2008
Resolution: Deficiency was cleared without class report due to location of deficiency not clearly stated on CG-5437A.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 March 2008
Resolved
Several explosive proof lighting fixtures were found to have condensation on the inside.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2008
Resolution: No condensation found on light fixtures that were inspected. Deficiency was cleared without class report due to location of deficiency not clearly stated on CG-5437A.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 21 March 2008
Resolved
Vessel's eye wash station located on the main deck starboard side forward of the superstructure was found inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 September 2008
Resolution: Inspection found this eye wash station in working order.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 December 2004
Resolved
Vessel allided with barge during docking and sustained a 10" X 2" hole in its port aft quarter. Damage Survey, Repair Proposal and repairs required prior to shifting or cargo operations.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 24 January 2005
Resolution: Received proper documentation satisfying requirement.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 21 September 2004
Resolved
All licensed officers missing valid UK endorsements as they all had expired this date.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 21 September 2004
Resolved 21 September 2004
Resolution: UK Faxed proof of issuing new endorsements this date.
Pollution Prevention/Response › Response Equipment › Protective Clothing
Issued 21 September 2004
Resolved
No level A chemical suits on board for the protection of personnel engaged in cleaning up or handling materials listed on the vessels COF. These suits to be provided to satisfaction of USCG prior to the carriage of these materials.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 September 2004
Resolved 4 October 2004
Resolution: Received certificate from Unitor that vessel received chemical suites
Deck/Cargo › Towing › Terminal Gear
Issued 21 September 2004
Resolved
Emergency Towing Equipment missing on the forecastle. Procure and install this to satisfaction of USCG Marine Inspector no later than Sept 28, 2006.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 September 2004
Resolved 4 October 2004
Resolution: Received certificate from Anchor Marine that the vessel received equipment for towing.
Navigation › Collision/Grounding Avoidance › Radar
Issued 28 June 2004
Resolved
Vessel granted inbound for inoperable secondary marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2008
Construction/Loadline › Markings
Issued 20 February 2004
Resolved
LOAD LINE DOES NOT HAVE CONTRASTING COLOR. RE - PAINT LOADLINE MARKINGS PRIOR TO DEPARTURE.
CITE: (ICLL 66) LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2004
Resolved 1 March 2004
Resolution: visually verified proper loadline while vessel was in port
Navigation › Piloting/Steering
Issued 20 February 2004
Resolved
LAST NOTICE TO MARINERS IS WEEK#51. PROVIDE WEEKS 52 - PRESENT PRIOR TO DEPARTURE. 33 CFR 164.33 a (1) (ii). LEGACY COMPONENT DESC: Local Notices to Mariners
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 22 February 2004
Resolution: Corrected prior to vessel deaparting PHIMS COTP zone.
Navigation › Piloting/Steering
Issued 20 February 2004
Resolved
46 CFR PARTS 153-155 ARE MISSING. PROVIDE CFR PARTS PRIOR TO DEPARTURE. 33 CFR 164.33 (b) LEGACY COMPONENT DESC: 46 CFR PARTS 153-155
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2004
Resolved 22 February 2004
Resolution: Corrected prior to vessel departing PHIMS COTP zone.
Lifesaving › Lifeboat
Issued 20 February 2004
Resolved
MISSING 01 FOOD RATION IN THE FREE FALL LIFEBOAT. CORRECT WITHIN 30 DAYS OR NEXT U.S PORT AFTER SAILING FOREIGN. CITE: ( SOLAS 74/78 CH III REG 41.8.12) LEGACY COMPONENT DESC: Food rations
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2004
Resolved 22 February 2004
Resolution: Corrected prior to vessel departing PHIMS COTP zone.
Electrical › Lighting (service)
Issued 4 February 2003
Resolved
explosion proof lighting throughout the cargo area had been altered such that it could not work as designed. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2003
Resolution: Rcvd class report attesting to proper repair. Ammended COC to reflect correction. No deficiencies currently outstanding.