Records from 1985 to 1997. Most recent: inspection, 12 August 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
12 August 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 406307
15 May 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 403549
23 October 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 396614
27 June 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 526621
30 October 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 384401
23 February 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 375356
15 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 372302
27 May 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 537155
5 April 1994
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 855971
23 March 1994
Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367005
10 September 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360789
9 September 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1144486
10 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 676728
7 August 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 441191
4 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 359861
2 August 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 842510
23 April 1993
Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 829048
19 December 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 455474
24 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 440058
15 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351774
19 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 87999
23 April 1992
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943777
5 February 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518299
10 June 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 344204
22 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 343218
21 April 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 919645
23 May 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337170
29 May 1987
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1027623
28 May 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 316407
4 June 1986
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 530025
11 December 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 305908
11 December 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1298328
18 October 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 524628
Navigation
Issued 12 August 1997
Resolved
Secondary marine radar reported inoperative. Vessel was given permission to enter the Port of Point Comfort with this equipment not operating.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Navigation
Issued 15 May 1997
Resolved
ARPA AND PRIMARY RADAR NOT OPERATIONAL.
Condition: Unknown
Due 20 May 1997
Resolved 21 May 1997
Navigation
Issued 15 June 1994
Resolved
A VIO OF 33 CFR 164.53 IN THAT THE VESSELS MASTER DID NOT REPORT INOPERABLEECHO DEPTH SOUNDER RECORDER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 June 1994
Resolved 10 November 1994
Lifesaving
Issued 15 June 1994
Resolved
A VIO OF SOLAS IN THAT THE VESSEL HAD LOOSE DRUMS ON DECK CONTAINING SLOPS AND RAGS.
Condition: Unknown
Due 16 June 1994
Resolved 10 November 1994
Navigation
Issued 15 June 1994
Resolved
A VIO OF 33 CFR 164.35(i) IN THAT THE ECHO DEPTH SOUNDER RECORDER WAS INOPERABLE WHILE TRANSITING THE DELAWARE RIVER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 June 1994
Resolved 10 November 1994
Lifesaving
Issued 23 March 1994
Resolved
PROVIDE KEEL CHAFING GEAR ON ALL LIFEBOATS.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Unknown
Issued 4 August 1993
Resolved
Vessel discharged plastic into the sea.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Deck/Cargo
Issued 2 August 1993
Resolved
Make permanent repairs to hydraulic leaks at pipe flange joint stbd side #8hatch, #1/#2 Hyd driven cargo pumps, & hatch cover actuating drive motor onstbd side of #2 hatch.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Construction/Loadline
Issued 2 August 1993
Resolved
Provide 30x30 mesh flame screens on ballast tank & stool space vents adja- cent to cargo tanks prior entry next U.S. port.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Prior to cargo transfer, complete Cargo Transfer Procedures, for cargo on board.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Prior to cargo discharge make permenent repairs to flange leak at #3 cargo line discharge from cargo pump base plate.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Prior to crude oil washing operations make permanent repairs to soft patched area of COW line portside at forcastle.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Install valve on drain line at bottom of IGS main forward of non-return valve prior to entry next U.S. port.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Prior to cargo transfer inert all cargo & slop tanks.
Condition: Unknown
Due 4 August 1993
Resolved 4 August 1993
Deck/Cargo
Issued 2 August 1993
Resolved
Remove drain hoses from bottom of p & s loading manifold drain pans & pro- vide permanent piping to slop tanks prior to entry next U.S. port.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 2 August 1993
Resolved
Make permanent repairs to damaged aft davit of the stbd life boat as specified in DNV report #11264 of 14JUL94.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Documentation
Issued 23 April 1993
Resolved
SHOW PROOF OF SPILL RESPONSE PLAN ABOARD AS REQUIRED BY COMDTINST 16450.32 NO LATER THAN 18 AUG 93.
Condition: Unknown
Due 18 August 1993
Resolved 10 June 1993
Construction/Loadline
Issued 23 April 1993
Resolved
AT NEXT U.S. PORT, MAKE AVAILABLE FOR INSPECTION ONE BALLAST TANK IN THE CARGO BLOCK/MID-SHIP HALF LENGTH AREA AS REQUIRED BY COMDT G-MVI POLICY LETTER 25-90 DTD 06 NOV 90. THE TANK TO BE INSPECTED WILL BE DETERMINED BYTHE COGNIZANT OCMI.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Fire Fighting
Issued 23 April 1993
Resolved
MAKE PERMANENT REPAIR IN WAY OF TEMPORARY REPAIR TO FIREMAIN LEAK OUTSIDE EMERGENCY FIREPUMP ROOM IN FORECASTLE PRIOR TO ARRIVAL AT NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Navigation
Issued 23 April 1993
Resolved
OBTAIN AND INSTALL PERMANENTLY MANUFACTURER'S APPROVAL PLATE FOR ARPA.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Documentation
Issued 21 April 1991
Resolved
PROVIDE ON BOARD THE VESSEL THE ORIGINAL CERTIFICATE OF FINANCIAL RESPONSIBILITY.
Condition: Unknown
Due 21 April 1991
Resolved 21 April 1991
Documentation
Issued 11 December 1985
Resolved
VESSEL SHALL NOT UTILIZE THE COW SYSTEM FOR COW OPERATIONS IN UNITED STATESWATERS UNTIL THE SYSTEM SURVEYS ARE COMPLETED, ACCEPTED AND SYSTEM ACCEPTANCE IS INDICATED ON THE IOPP CERTIFICATE FORM B. CARRIAGE OF CRUDE OIL IS AUTHORIZED DUE TO COMPLIANCE WITH SBT.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Documentation
Issued 11 December 1985
Resolved
PLACE ON BOARD EVIDENCE OF ACCEPTANCE OF THE HIGH VELOCITY P/V VALVES BY BOTH THE ADMINISTRATION AND ITS RECOGNIZED CLASSIFICATION SOCIETY. (MSM 19.K.5)
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985