MAURY USCG vessel records Sign in
← All vessels

AEGEAN TRADER

AEGEAN TRADER is a 1980 tank ship. The Coast Guard has recorded 45 inspections since 1987, most recently in January 2007, along with 45 deficiencies and 7 operational controls.

Records from 1987 to 2007. Most recent: operational control imposed, 27 January 2007.

Built
1980
Last inspected
27 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7612204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
225862
Flag
NORWAY
—
Maury page id
psix-225862

Inspections, by type

…with no type recorded26
Years with a record 15 calendar years (1987–2007)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10320 - Convention (Subpart B), Net Ton
31374 - Dead Weight, Ton
39173 - Displacement, Ton
18654 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

27 January 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862509
27 January 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862624
10 September 2006 ISPS II Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2774205
8 September 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2773329
31 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2666773
22 May 2006 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2656270
17 February 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2586915
16 February 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2586990
2 October 2005 MARPOL Annex I Examination · COC-TVE Annual · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2505493
12 July 2005 Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2424643
6 July 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2416879
28 February 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2300794
26 September 2004 ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2205840
16 April 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2045316
2 February 2004 MTSA/ISPS Verification · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999440
15 January 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999588
18 November 2003 Certificate of Compliance · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1948856
23 August 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1919573
13 September 2002 MARPOL Annex I Examination · Ballast Water Examination · Tank Vessel Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1675497
16 September 2001 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 503573
3 May 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 415521
3 May 1998 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1123902
26 October 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 384277
16 December 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 181031
16 December 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 842278
20 June 1994 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 367794
20 June 1994 Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330683
31 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365636
22 December 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 444863
14 June 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 647139
12 June 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 358891
12 June 1993 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 827302
12 June 1993 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1156901
15 April 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 646792
30 March 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 479600
2 December 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 530511
26 June 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351622
13 June 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 957859
27 April 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 350319
7 March 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 468071
10 June 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 344305
10 June 1991 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1241837
13 June 1989 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 330856
13 June 1989 Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 893960
4 April 1987 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022493

Deficiency record · 45

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 September 2006 Resolved
Vessel Response Plan did not have the current contact phone numbers for the COPT'S.
Action required: 705 - Other - as specified
Due 10 September 2006
Resolved 10 September 2006
Resolution: Corrected by the QI who was on board during the inspection.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 September 2006 Resolved
The door inside the CO2 room has been removed and the entry way has been welded closed. However, this change has not been made on the fire plan. In addition, a section of the wall in the hydraulic room adjoining the CO2 room is missing. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, satisfactorily verified on board updated fire control plans indicated spaces next to CO2 room.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 10 September 2006 Resolved
Only one cargo pump had all three temperature probes connected; one to the main casing, one to the lower bearing and one to the upper bearings. The other pumps had at least one of the probes removed for unknown reasons. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, satisfactorily verified ship''s compliance with the IBS code Ch. 17 requirements for particular UREA solution cargo which is not required the temperature sensors on the cargo pumps.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 September 2006 Resolved
During cargo operations we found the aft starboard scupper leaking.
Action required: 705 - Other - as specified
Due 10 September 2006
Resolved 10 September 2006
Resolution: The QI Representative on board had the crew secure the scupper.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 September 2006 Resolved
The ventilation ducting in the forward Bos'n store is hold. No action has been taken by the crew to temporary or permanently repair this. No one had informed the Master about this and no reports have been sent too the company DPA regarding this. A Classification Representative must look into this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, ventilation duct in bosun store has been repaired and vent. switch has been replaced by new one and found in order.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2006 Resolved
The Canopy support brackets will not work due to excessive corrosion. The crutches do not have a means of securing them and the top sheaves on the davits are not being properly maintained. No one has greased them in some time. The starboard limit switch had to be held back in order to retrieve the lifeboat. A Classification Representative must inspect the lifeboat and its equipment.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, satisfactoryily examined SB lifeboat limit switcher fixing, painting in contr. colour the release handle, ren. boat hook, alignment of canopy support bars, greasing of the top sheaves and fxing of the crutches.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 September 2006 Resolved
The forward liferaft emergency light was not working. Also, the lower half of the glass cover was filled with water. Three quarters of the globe could not be seen due to an excessive amount of paint. In addition, the forward Bos'n room fan could not be turned on at the local power source. The electrician had to go to the main switch board. A Classification Representative must look at this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report attesting to repairs have been made and found in order.
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 10 September 2006 Resolved
The pipe for the ballast gauging system under the cat walk near cargo tank two (2) center has a soft patch on it. System must be inspected by a Classification Representative.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, deck air gauge pipe under the catwalk near 2 cargo tank has been replaced by new one and found in order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 September 2006 Resolved
The sewage tank has several holes in it at the top of the tank. No one has reported this to the Master or company DPA. A sewage certificate has been issued by the Classification Society. In addition the crew has not been maintaining it as per the manufacturers requirements. Daily, weekly, monthly, semi-annual and annual inspections are not being done. A Class Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, sewage tank after repair has been satisfactorily examined on board.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 September 2006 Resolved
The ventilation in the rope stores is holed. No one has reported this to the Master or company DPA. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, vent. duct in rope store has been repaired and found in order.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 September 2006 Resolved
The fresh water piping, which are located in the rope stores are leaking. No one has reported this to the Master or DPA. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, wasted FW pipe in rope store has been replaced by new one and found in order.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 September 2006 Resolved
The galley doors do not operate properly. Their self-closing devices are missing or need adjustments. There is a hole in the paneling slightly above the deck near the aft door leading to the poop deck. None of these items have been reported to the Master or DPA. A Classification Representative must inspect this space.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, the galley''s door arrangement have been replaced by new one and crack in the sink has been repaired by welding, repaired the hole in galley''s bulkhead.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 10 September 2006 Resolved
The Fire Training Manual is missing from the Officer's lounge. Master had requested a copy from the Company on 10 July 2006. A Classification Representative must look into this in relation to ISM.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, satisfactorily verified fire training manual in officer''s lounge.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 10 September 2006 Resolved
The ship does not have a bell. A Classification Representative must inspect.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, verified ships bell location on forecastle mast and found in order.
Fire Fighting › Fire Main › Condition
Issued 10 September 2006 Resolved
The main supply line for the foam system has a small pin hole on the right side of the valve looking down on it. A Classification representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, verified repaired foam supply line and found in order.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 10 September 2006 Resolved
Approximately 1/4 of the fixed containment for the diesel oil vent located on the starboard side next to the foam room is filled with concrete. No one has informed the Master or DPA of this. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, SB DO bunk station has a new containment plate and satisfactorily verified on board.
Deck/Cargo › Cargo Heating › General
Issued 10 September 2006 Resolved
The steam return line for the number 3, cargo tank is leaking. No one has informed the Master or DPA of this. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, No. 3 SB replaced deck steam pipe, verified and found in order.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 September 2006 Resolved
Mixed garbage was found in the containers located on the port side. This is the final staging area prior to disposal into the sea. The crew is burning all types of items in the incinerator most of which are against the company policy as listed in the Garbage Plan. The incinerator is not working according to the manufacturer. The orating arm is broken. No one has informed the Master or DPA.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, satisfactorily verified ships updated garbage plan and procedures for the incinerator.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 10 September 2006 Resolved
The Echo Depth Sounder is not working. Repairs could not be made while in port due to lack of parts. A LOD was issued for both arrival and departure. This has been an ongoing problem for some time. The Company is aware of it but has not taken any meaningful action to repair it. A Classification Representative must inspect this.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd class report, new echo sounder ELAC-LAZ 5100 ser. no. 1033 has been satisfactorily tested on board.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 10 September 2006 Resolved
The COTP questions the vessel's SMS. An external audit is requested to be conducted by the Flag State or Recognized Organization within 60, days to determine whether the ship is operating in accordance with the ISM Code.
Action required: 705 - Other - as specified
Resolved 26 November 2006
Resolution: Rcvd vessel''s external audit by their classification society, Master, CO, Ch. En., and crew held discussion of their duties/responsibilities with regards to SMS and SSP. For further information see attached class audit to activity.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 17 February 2006 Resolved
The vessel has basic protein type form on board. Several of the chemicals that they are authorized to carry according to the COF require an alcohol type foam. Company must provide documentation that the foam on board can be used for alcohol fires or replace the foam. Reference BCH 3.14
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 March 2006
Resolved 22 May 2006
Resolution: Received report showing fire extinguishing agent is suitable for alcohol fires.
Documentation › Certificates/Documents
Issued 18 November 2003 Resolved
Prior to next U.S. port visit, after foreign voyage, class society must certify the throughput quantity of the OWS on the IOPP certificate. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Resolved 2 February 2004
Resolution: Class certified throughput quantity of the OWS on IOPP certificate.
Pollution Prevention/Response › Prevention Equipment
Issued 13 September 2002 Resolved
Small discharge containment for cylinder oil tank on starboard side of vessel missing. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2002
Resolution: Received Class Report verifying small discharge containment installed for cylinder oil tank on starboard side of vessel.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 September 2002 Resolved
Provide approval from the administration concerning the hydrostatic test dates of the Halon system bottles where manufacture dates are 1977. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2002
Resolution: Classification society provided statement that the Flag state doesn''''t require hydrostatic testing of Halon Bottles and the class society has waived the requirement for hydraulic testing of Halon bottles since it is being phased out.
Fire Fighting › Means of Escape
Issued 13 September 2002 Resolved
Make the engine room fire doors self closing as original. LEGACY COMPONENT DESC: Doorways
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2002
Resolution: Received class report that latch/lock on port side door replaced and both port and starboard side doors spring loaded closing arrangement was adjusted. The doors were inspected/tested and are in working order.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 September 2002 Resolved
Repair main engine turbo charge where leaking oil. LEGACY COMPONENT DESC: Turbocharger
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 September 2002
Resolution: Received Class Report verifying the lube oil gasket cover on forward turbocharger was renewed and all arrangements cleaned. Turbocharger no longer leaking.
Documentation
Issued 3 May 1998 Resolved
ENSURE IOPP IS PROPERLY ENDORSED
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Navigation
Issued 3 May 1998 Resolved
INSTALL AUTOPILOT ALARM OR OVERIDE DEVICE
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Deck/Cargo
Issued 3 May 1998 Resolved
IN YARD, REPLACE ALL FLAME SCREENS IN P/V BREAKERS
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Engineering
Issued 3 May 1998 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Unknown
Issued 3 May 1998 Resolved
COMPLY WITH CONDITIONS OF CLASS REPORT DATED 29NOV97 (LTR# CC0700167)
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Documentation
Issued 3 May 1998 Resolved
PROVIDE LETTER FROM FLAG OR CLASS STATING MANUEVERING CHARACTERISTICS REQUIRED BY IMO RESOLUTION A.751(18); 33CFR157.445 HAVE BEEN MET
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Documentation
Issued 3 May 1998 Resolved
MAKE PROPER LOG ENTRIES FOR UNDER KEEL CLEARENCE REQUIRED BY 33CFR157.455
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Deck/Cargo
Issued 3 May 1998 Resolved
PROVIDE RECORDING PAPER FOR ODME
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Construction/Loadline
Issued 3 May 1998 Resolved
MAKE BALLAST TANK READY FOR USCG INSPECTION PRIOR TO NEXT U.S. PORT
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Lifesaving
Issued 3 May 1998 Resolved
APPLY RETRO-REFLECTIVE TAPE TO LIFESAVING GEAR
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Lifesaving
Issued 26 October 1995 Resolved
ONE 16 MAN AND ONE 6 MAN LIFERAFT WERE SENT OUT FOR INSPECTION.
Condition: Unknown
Due 27 October 1995
Resolved 26 October 1995
Deck/Cargo
Issued 26 October 1995 Resolved
ULLAGE TUBE FOR 1 AND 2 STARBOARD TANKS HAVE HOLES IN THE FLAME SCREENS. ALL OTHER ULLAGE TUBE FLAME SCREEN HAVE A DESIGN PROBLEM.
Condition: Unknown
Due 23 December 2000
Resolved 23 December 2000
Construction/Loadline
Issued 20 June 1994 Resolved
PRIOR TO NEXT U.S. PORT PROVIDE CLASSIFICATION SOCIETY ATTESTATION OF PROPER OPERATION OF THE BALLAST DISCHARGE OIL MONITOR AND CONTROL UNIT. UNTIL SUCH TIME ALL BALLAST AND TANK CLEANING WATER IS TO BE RETAINED ONBOARD AND DISCHARGED AT APPROPRIATE FACILITIES ASHORE._x001C_
Condition: Unknown
Due 20 July 1994
Resolved 22 June 1994
Deck/Cargo
Issued 12 June 1993 Resolved
CONDUCTED A ANNUAL/TANK VESSEL EXAMINATION OF THE VESSEL AND FOUND THAT THEOPERATOR FAILED TO ENSURE THAT THE SCUPPERS WERE FITTED PROPERLY. DURING THE DECK WALK THE BOARDING TEAM FOUND THAT THE SCUPPERS WERE NOT FITTED PROPERLY, YOU COULD SEE DAYLIGHT AROUND THE SIDES OF THE SCUPPERS.
Condition: Unknown
Due 31 December 1993
Resolved 31 December 1993
Fire Fighting
Issued 4 April 1987 Resolved
FIRE HOSE BOX #3 DECK AFT MISSING SPANNER WRENCH.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Accommodation/Occupational Safety
Issued 4 April 1987 Resolved
0-3 DECK AFT; UPPER VENT DAMPER FROZEN OPEN.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Construction/Loadline
Issued 4 April 1987 Resolved
PUMPROOM WATERTIGHT DOORS PORT AND STARBOARD. NO EFFECTIVE SEAL DUE TO WASTED SEATS FOR DOGS.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Deck/Cargo
Issued 4 April 1987 Resolved
#6 PV VALVE GASKET AROUND FLAME SCREEN PARTIALLY MISSING.
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987
Fire Fighting
Issued 4 April 1987 Resolved
FIRE HOSE BOX #3 DECK AFT FROZEN SHUT (RUSTED HINGES).
Condition: Unknown
Due 4 April 1987
Resolved 4 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.