← All vessels
AEGEAN TRADER
AEGEAN TRADER is a 1980 tank ship. The Coast Guard has recorded 45 inspections since 1987, most recently in January 2007, along with 45 deficiencies and 7 operational controls.
Records from 1987 to 2007. Most recent: operational control imposed, 27 January 2007.
- Built
- 1980
- Last inspected
- 27 January 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 45 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7612204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAVF5
225862
Flag
NORWAY
—
Maury page id
psix-225862
Inspections, by type
…with no type recorded26
Years with a record
15 calendar years (1987–2007)
The 45 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10320 - Convention (Subpart B), Net Ton
31374 - Dead Weight, Ton
39173 - Displacement, Ton
18654 - Convention (Subpart B), Gross Ton
31374 - Dead Weight, Ton
39173 - Displacement, Ton
18654 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 45
27 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862509
27 January 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862624
10 September 2006
ISPS II Exam · Ballast Water Examination · COC-TVE Renew · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2774205
8 September 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2773329
31 May 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2666773
22 May 2006
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2656270
17 February 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2586915
16 February 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2586990
2 October 2005
MARPOL Annex I Examination · COC-TVE Annual · ISPS III Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2505493
12 July 2005
Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2424643
6 July 2005
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2416879
28 February 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2300794
26 September 2004
ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2205840
16 April 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2045316
2 February 2004
MTSA/ISPS Verification · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999440
15 January 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999588
18 November 2003
Certificate of Compliance · Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1948856
23 August 2003
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1919573
13 September 2002
MARPOL Annex I Examination · Ballast Water Examination · Tank Vessel Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1675497
16 September 2001
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 503573
3 May 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 415521
3 May 1998
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1123902
26 October 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 384277
16 December 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 181031
16 December 1994
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 842278
20 June 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 367794
20 June 1994
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330683
31 March 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365636
22 December 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 444863
14 June 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 647139
12 June 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 358891
12 June 1993
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 827302
12 June 1993
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1156901
15 April 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 646792
30 March 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 479600
2 December 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 530511
26 June 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351622
13 June 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 957859
27 April 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 350319
7 March 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 468071
10 June 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 344305
10 June 1991
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1241837
13 June 1989
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 330856
13 June 1989
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 893960
4 April 1987
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022493
Deficiency record · 45
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 September 2006
Resolved
Vessel Response Plan did not have the current contact phone numbers for the COPT'S.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 September 2006
Resolved
The door inside the CO2 room has been removed and the entry way has been welded closed. However, this change has not been made on the fire plan. In addition, a section of the wall in the hydraulic room adjoining the CO2 room is missing. A Classification Representative must inspect this.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 10 September 2006
Resolved
Only one cargo pump had all three temperature probes connected; one to the main casing, one to the lower bearing and one to the upper bearings. The other pumps had at least one of the probes removed for unknown reasons. A Classification Representative must inspect this.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 September 2006
Resolved
During cargo operations we found the aft starboard scupper leaking.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 September 2006
Resolved
The ventilation ducting in the forward Bos'n store is hold. No action has been taken by the crew to temporary or permanently repair this. No one had informed the Master about this and no reports have been sent too the company DPA regarding this. A Classification Representative must look into this.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2006
Resolved
The Canopy support brackets will not work due to excessive corrosion. The crutches do not have a means of securing them and the top sheaves on the davits are not being properly maintained. No one has greased them in some time. The starboard limit switch had to be held back in order to retrieve the lifeboat. A Classification Representative must inspect the lifeboat and its equipment.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 September 2006
Resolved
The forward liferaft emergency light was not working. Also, the lower half of the glass cover was filled with water. Three quarters of the globe could not be seen due to an excessive amount of paint. In addition, the forward Bos'n room fan could not be turned on at the local power source. The electrician had to go to the main switch board. A Classification Representative must look at this.
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 10 September 2006
Resolved
The pipe for the ballast gauging system under the cat walk near cargo tank two (2) center has a soft patch on it. System must be inspected by a Classification Representative.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 September 2006
Resolved
The sewage tank has several holes in it at the top of the tank. No one has reported this to the Master or company DPA. A sewage certificate has been issued by the Classification Society. In addition the crew has not been maintaining it as per the manufacturers requirements. Daily, weekly, monthly, semi-annual and annual inspections are not being done. A Class Representative must inspect this.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 September 2006
Resolved
The ventilation in the rope stores is holed. No one has reported this to the Master or company DPA. A Classification Representative must inspect this.
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 September 2006
Resolved
The fresh water piping, which are located in the rope stores are leaking. No one has reported this to the Master or DPA. A Classification Representative must inspect this.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 September 2006
Resolved
The galley doors do not operate properly. Their self-closing devices are missing or need adjustments. There is a hole in the paneling slightly above the deck near the aft door leading to the poop deck. None of these items have been reported to the Master or DPA. A Classification Representative must inspect this space.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 10 September 2006
Resolved
The Fire Training Manual is missing from the Officer's lounge. Master had requested a copy from the Company on 10 July 2006. A Classification Representative must look into this in relation to ISM.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 10 September 2006
Resolved
The ship does not have a bell. A Classification Representative must inspect.
Fire Fighting › Fire Main › Condition
Issued 10 September 2006
Resolved
The main supply line for the foam system has a small pin hole on the right side of the valve looking down on it. A Classification representative must inspect this.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 10 September 2006
Resolved
Approximately 1/4 of the fixed containment for the diesel oil vent located on the starboard side next to the foam room is filled with concrete. No one has informed the Master or DPA of this. A Classification Representative must inspect this.
Deck/Cargo › Cargo Heating › General
Issued 10 September 2006
Resolved
The steam return line for the number 3, cargo tank is leaking. No one has informed the Master or DPA of this. A Classification Representative must inspect this.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 10 September 2006
Resolved
Mixed garbage was found in the containers located on the port side. This is the final staging area prior to disposal into the sea. The crew is burning all types of items in the incinerator most of which are against the company policy as listed in the Garbage Plan. The incinerator is not working according to the manufacturer. The orating arm is broken. No one has informed the Master or DPA.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 10 September 2006
Resolved
The Echo Depth Sounder is not working. Repairs could not be made while in port due to lack of parts. A LOD was issued for both arrival and departure. This has been an ongoing problem for some time. The Company is aware of it but has not taken any meaningful action to repair it. A Classification Representative must inspect this.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 10 September 2006
Resolved
The COTP questions the vessel's SMS. An external audit is requested to be conducted by the Flag State or Recognized Organization within 60, days to determine whether the ship is operating in accordance with the ISM Code.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 17 February 2006
Resolved
The vessel has basic protein type form on board. Several of the chemicals that they are authorized to carry according to the COF require an alcohol type foam. Company must provide documentation that the foam on board can be used for alcohol fires or replace the foam. Reference BCH 3.14
Documentation › Certificates/Documents
Issued 18 November 2003
Resolved
Prior to next U.S. port visit, after foreign voyage, class society must certify the throughput quantity of the OWS on the IOPP certificate. LEGACY COMPONENT DESC: IOPP Certificate
Pollution Prevention/Response › Prevention Equipment
Issued 13 September 2002
Resolved
Small discharge containment for cylinder oil tank on starboard side of vessel missing. LEGACY COMPONENT DESC: Fixed Containment
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 September 2002
Resolved
Provide approval from the administration concerning the hydrostatic test dates of the Halon system bottles where manufacture dates are 1977. LEGACY COMPONENT DESC: Tanks
Fire Fighting › Means of Escape
Issued 13 September 2002
Resolved
Make the engine room fire doors self closing as original. LEGACY COMPONENT DESC: Doorways
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 September 2002
Resolved
Repair main engine turbo charge where leaking oil. LEGACY COMPONENT DESC: Turbocharger
Documentation
Issued 3 May 1998
Resolved
ENSURE IOPP IS PROPERLY ENDORSED
Navigation
Issued 3 May 1998
Resolved
INSTALL AUTOPILOT ALARM OR OVERIDE DEVICE
Deck/Cargo
Issued 3 May 1998
Resolved
IN YARD, REPLACE ALL FLAME SCREENS IN P/V BREAKERS
Engineering
Issued 3 May 1998
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR
Unknown
Issued 3 May 1998
Resolved
COMPLY WITH CONDITIONS OF CLASS REPORT DATED 29NOV97 (LTR# CC0700167)
Documentation
Issued 3 May 1998
Resolved
PROVIDE LETTER FROM FLAG OR CLASS STATING MANUEVERING CHARACTERISTICS REQUIRED BY IMO RESOLUTION A.751(18); 33CFR157.445 HAVE BEEN MET
Documentation
Issued 3 May 1998
Resolved
MAKE PROPER LOG ENTRIES FOR UNDER KEEL CLEARENCE REQUIRED BY 33CFR157.455
Deck/Cargo
Issued 3 May 1998
Resolved
PROVIDE RECORDING PAPER FOR ODME
Construction/Loadline
Issued 3 May 1998
Resolved
MAKE BALLAST TANK READY FOR USCG INSPECTION PRIOR TO NEXT U.S. PORT
Lifesaving
Issued 3 May 1998
Resolved
APPLY RETRO-REFLECTIVE TAPE TO LIFESAVING GEAR
Lifesaving
Issued 26 October 1995
Resolved
ONE 16 MAN AND ONE 6 MAN LIFERAFT WERE SENT OUT FOR INSPECTION.
Deck/Cargo
Issued 26 October 1995
Resolved
ULLAGE TUBE FOR 1 AND 2 STARBOARD TANKS HAVE HOLES IN THE FLAME SCREENS. ALL OTHER ULLAGE TUBE FLAME SCREEN HAVE A DESIGN PROBLEM.
Construction/Loadline
Issued 20 June 1994
Resolved
PRIOR TO NEXT U.S. PORT PROVIDE CLASSIFICATION SOCIETY ATTESTATION OF PROPER OPERATION OF THE BALLAST DISCHARGE OIL MONITOR AND CONTROL UNIT. UNTIL SUCH TIME ALL BALLAST AND TANK CLEANING WATER IS TO BE RETAINED ONBOARD AND DISCHARGED AT APPROPRIATE FACILITIES ASHORE._x001C_
Deck/Cargo
Issued 12 June 1993
Resolved
CONDUCTED A ANNUAL/TANK VESSEL EXAMINATION OF THE VESSEL AND FOUND THAT THEOPERATOR FAILED TO ENSURE THAT THE SCUPPERS WERE FITTED PROPERLY. DURING THE DECK WALK THE BOARDING TEAM FOUND THAT THE SCUPPERS WERE NOT FITTED PROPERLY, YOU COULD SEE DAYLIGHT AROUND THE SIDES OF THE SCUPPERS.
Fire Fighting
Issued 4 April 1987
Resolved
FIRE HOSE BOX #3 DECK AFT MISSING SPANNER WRENCH.
Accommodation/Occupational Safety
Issued 4 April 1987
Resolved
0-3 DECK AFT; UPPER VENT DAMPER FROZEN OPEN.
Construction/Loadline
Issued 4 April 1987
Resolved
PUMPROOM WATERTIGHT DOORS PORT AND STARBOARD. NO EFFECTIVE SEAL DUE TO WASTED SEATS FOR DOGS.
Deck/Cargo
Issued 4 April 1987
Resolved
#6 PV VALVE GASKET AROUND FLAME SCREEN PARTIALLY MISSING.
Fire Fighting
Issued 4 April 1987
Resolved
FIRE HOSE BOX #3 DECK AFT FROZEN SHUT (RUSTED HINGES).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.