← All vessels
CAPE MALEAS
CAPE MALEAS is a 1976 freight ship. The Coast Guard has recorded 14 inspections since 1985, most recently in October 1998, along with 24 deficiencies and 2 operational controls.
Records from 1985 to 1998. Most recent: inspection, 2 October 1998.
- Built
- 1976
- Last inspected
- 2 October 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7613026 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3DI2
225883
Flag
GREECE
—
Maury page id
psix-225883
Inspections, by type
…with no type recorded14
Years with a record
7 calendar years (1985–1998)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7622 - Regulatory (Subpart C or D), Net Ton
16023 - Dead Weight, Ton
9942 - Regulatory (Subpart C or D), Gross Ton
16023 - Dead Weight, Ton
9942 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
2 October 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 421033
11 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413741
4 April 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 528922
17 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 677752
12 March 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401294
9 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 677743
3 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 364234
12 October 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 339791
7 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 449919
4 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 536366
12 August 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 317774
8 June 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 316593
8 November 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305274
8 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 471681
Deficiency record · 24
Construction/Loadline
Issued 12 March 1997
Resolved
RENEW AS ORIGINAL DETERIORATED CO2 ROOM BULKHEAD, IN WAY OF THE A/C COMPRESSOR ROOM._x001C_ SEE ICLL AN. 1/17
Fire Fighting
Issued 12 March 1997
Resolved
RENEW THE DAMAGED/TORN PROTECTIVE HOOD FOR THE FIREMANS OUTFIT STORED IN THE ENGINE ROOM._x001C_ SEE SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 12 March 1997
Resolved
CONDUCT A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR._x001C_ SEE SOLAS 74 (AMENDED) III/18.3.4-3.9, 18.3.10-3.13
Lifesaving
Issued 12 March 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 12 March 1997
Resolved
PROVE THE PROPER OPERATION OF THE STARBOARD LIFEBOAT._x001C_ SEE SOLAS 74 (AMENDED) III/19.2
Accommodation/Occupational Safety
Issued 12 March 1997
Resolved
REPAIR AND PROVE THE PROPER OPERATION OF THE INOPERABLE VENTILATION CLOSURES LOCATED ON THE AFT STBD BOAT DECK AND FWD PORT BOAT DECK._x001C_ SEE SOLAS 60 II/47(a)
Fire Fighting
Issued 12 March 1997
Resolved
PROVIDE ONBOARD AN INTERNATIONAL SHORE CONNECTION MEETING THE REQUIREMENTS OF SOLAS 60 II/56(h)
Lifesaving
Issued 12 March 1997
Resolved
END FOR END THE PORT AND STBD LIFEBOAT FALLS._x001C_ SEE SOLAS 74 (AMENDED) III/19.4
Fire Fighting
Issued 12 March 1997
Resolved
Prove proper operation of the emergency fire pump._x001C_ See Solas 74 (Amended) II-2/21
Lifesaving
Issued 12 March 1997
Resolved
RENEW AS ORIGINAL DETERIORATED DECK DRAIN PIPING, IN WAY OF THE CO2 ROOM AND STBD SIDE OF STEERING FLAT._x001C_ SEE SOLAS (AMENDED) 1/11(a)
Navigation
Issued 12 March 1997
Resolved
PROVIDE ON BRIDGE A DEVIATION TABLE FOR THE MAGNETIC COMPASS. _x001C_ SEE 33 C.F.R. 164.35(c)
Lifesaving
Issued 12 March 1997
Resolved
PROVIDE ONE LIFEJACKET TO REPLACE DETERIORATED LIFEJACKET._x001C_ SEE SOLAS 74 (AMENDED) III/19.4
Navigation
Issued 3 February 1994
Resolved
THE SUBJ VESSEL'S COAST PILOT #5 WAS OUTDATED. THE CURRENT EDITION IS THE TWENTY FOURTH AND THE PUBLICATION HELD BY THE VESSEL WAS THE TWENTY FIRST. THIS PUBLICATION CANCELS THE PREVIOUS EDITION WHEN A NEW ONE IS PRINTED. THE LIGHT LIST VOL III WAS A 1990 EDITION WITH NO CORRECTIONS.
Navigation
Issued 3 February 1994
Resolved
THE SUBJ VESSEL FAILED TO CONDUCT A PRE-ARRIVAL TEST PRIOR TO ENTRANCE INTOTHE PORT OF TAMPA.
Navigation
Issued 3 February 1994
Resolved
THE SUBJ VESSEL'S GYRO COMPASS WAS INOPERABLE.
Navigation
Issued 3 February 1994
Resolved
THE SUBJ VESSEL WAS MISSING A BLOCK DIAGRAM OF OPERATING INSTRUCTIONS FOR THE STEERING GEAR CHANGE OVER.
Engineering
Issued 3 February 1994
Resolved
THE SUBJ VESSEL'S BUNKER TRANSFER PROCEDURES WERE MISSING.
Documentation
Issued 3 February 1994
Resolved
THE OIL POLLUTION PLACARD WAS MISSING.
Documentation
Issued 3 February 1994
Resolved
THE DOI WAS NOT RETAINED FOR THIRTY DAYS. THE VESSEL RECEIVED BUNKERS THE 2 FEB 1994.
Navigation
Issued 8 June 1987
Resolved
VESSEL DID NOT HAVE ON BOARD CURRENT TIDE TABLES AS REQUIRED BY 33 CFR 164.33 (A)(3)(I).
Navigation
Issued 8 June 1987
Resolved
VESSEL DID NOT HAVE ON BOARD CHART 11537 FOR TRANSIT IN COTP WILMINGTON ZONE AS REQUIRED BY 33 CFR 164.33 (A)(1)
Navigation
Issued 8 November 1985
Resolved
VESSEL DID NOT HAVE POSTED ON THE BRIDGE THE SIMPLE OPERATING INSTRUCTIONS WITH A BLOCK DIAGRAM FOR THE CHANGE OVER TO REMOTE STEERING GEAR SYSTEM AS REQUIRED BY 33CFR164.35(K).
Navigation
Issued 8 November 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 8 November 1985
Resolved
VESSEL DID NOT HAVE ONBOARD THE WARNING STATEMENT ON THE FACT SHEET AS REQUIRED BY 33CFR164.35(G)(7).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.